Lock Assembly Drawing Index
Function
ANSI A156.2, 1996, Series 4000, Grade 1
Trim
Chassis
SCHLAGE
ANSI
DESCRIPTION
OUTSIDE FUNCTION
INSIDE FUNCTION
Page
Page
ND80
F86
Storeroom Lock*
Lever is fi xed. Entrance
by key only.
Inside lever is always
unlocked and is always
free for immediate
egress.
63
8
ND80-RX
Storeroom Lock*
with Request to
Exit
Same as ND80.
Same as ND80.
A microswitch
attached to the chassis
is activated when the
lever is rotated. The
switch signals use of the
lever to security systems
allowing non-disruptive
egress.
64
9
ND80EL
Storeroom Lock—
Electrically Locked
(Fail Safe)*
Lever is continuously
locked electrically.
Unlocked by switch or
power failure. When
locked, key retracts latch.
Inside lever is always
unlocked and is always
free for immediate
egress.
65
10
ND80EL-RX
Storeroom Lock—
Electrically
Unlocked
(Fail Safe)* with
Request to Exit
Same as ND80EL-RX.
Same as ND80EL.
A microswitch
attached to the chassis
is activated when the
lever is rotated. The
switch signals use of the
lever to security systems
allowing non-disruptive
egress.
66
11
ND80EU
Storeroom Lock—
Electrically Locked
(Fail Secure)*
Lever is continuously
locked mechanically until
unlocked by electric
current. When locked,
key retracts latch.
Inside lever is always
unlocked and is always
free for immediate
egress.
67
12
ND80EU-RX
Storeroom Lock—
Electrically Locked
(Fail Secure)
with Request to
Exit*
Same as ND80EU-RX.
Same as ND80EU.
A microswitch
attached to the chassis
is activated when the
lever is rotated. The
switch signals use of the
lever to security systems
allowing non-disruptive
egress.
68
13
ND82
F87
Institution Lock*†
Lever is fi xed. Entrance
by key only.
Lever is fi xed. Exit by
key only.
69
28
NOTE: Any function with deadlatch locks latchbolt when door is closed. See page iii for identifi cation.
*Available with Small Format Interchangeable Core.
† Caution:
These locks on residences and any door in any structure which is used for egress are a life safety hazard in times of emergency
and their use is not recommended. Installation should be in accordance with existing codes only.