47629519 Rev. C
EN-21
EN
TROUBLE
DISPLAY
POSSIBLE CAUSE
REMEDY
W
ATER IN
THE SY
STEM
the temperature control probe
is positioned improperly or
faulty.
Check the probe; if the trouble persists,
replace it.
fan pressure / temperature
switch defective or burned out
turn off the dryer and call your local
Ingersoll Rand distributor.
high pressure / temperature
switch defective or burned out.
turn off the dryer and call your local
Ingersoll Rand distributor.
gas leakage in the refrigerating
circuit
turn off the dryer and call your local
Ingersoll Rand distributor.
defective fan.
Replace the fan.
Protection fuse burned out (if
present).
Replace the fuse.
the temperature control probe
is positioned improperly or
faulty.
Check the probe; if the trouble persists,
replace it.
gas leakage in the refrigerating
circuit without load.
turn off the dryer and call your local
Ingersoll Rand distributor.
the temperature control probe
is positioned improperly or
faulty.
Check the probe; if the trouble persists,
replace it.
series of alarms very close to
each other.
Call your local Ingersoll Rand distributor.
LO
W PRESSURE IN
THE LINE
Ice formation in the evaporator.
Check the probe; if the trouble persists,
replace it.
Check the electronic control board; if
the trouble persists, replace it.
Contact our service Centre to check the
gas charge.
Clog.
Check if the connecting tubing is
clogged; in case proceed accordingly.
Check if any valves are closed.
Check the condition of any filter.
air flows continuously through
the condensate drainage.
drainage solenoid valve jammed, clean
or replace it.
verify the condensate drainage times
set on the electronic control board
(C8 and C9).
Check the signal from the control board:
if it is continuous, replace the control
board.
RELEASED 23/May/2019 07:27:22 GMT
Содержание RS11i
Страница 24: ...ingersollrandproducts com 2019 Ingersoll Rand RELEASED 23 May 2019 07 27 22 GMT...
Страница 52: ...ingersollrandproducts com 2019 Ingersoll Rand RELEASED 23 May 2019 07 27 22 GMT...
Страница 79: ...RELEASED 23 May 2019 07 27 22 GMT...
Страница 80: ...ingersollrandproducts com 2019 Ingersoll Rand RELEASED 23 May 2019 07 27 22 GMT...
Страница 106: ...RELEASED 23 May 2019 07 27 22 GMT...
Страница 107: ...RELEASED 23 May 2019 07 27 22 GMT...
Страница 108: ...ingersollrandproducts com 2019 Ingersoll Rand RELEASED 23 May 2019 07 27 22 GMT...