80174964_ed1
5
Operation
Clockwise rotation of screw (1) will open the seat in the
master regulator and will increase the pressure between the
master regulator and solenoid valve (4). Do not try to exceed
11 bar or 160 psig. The pressure you adjust at the slave
regulator will be slightly higher than the working pressure at
the starter. In order to easily adjust the working pressure
install a gauge on port (2).
(Dwg. 80177215)
The master pressure regulator is designed as a relieving
regulator. When the pressure below the diaphragm reaches
1.5 bars over the adjusted pressure, the regulator exhausts
the excess pressure.
Schematic
For inertia drive applications:
For pre-engaged drive applications:
(Dwg. 80177223)
1
4
2