Ingersoll-Rand RR250-F30 Скачать руководство пользователя страница 4

4

80174964_ed1

Description

The RR250-F30 includes valve and regulator functions.

The RR250 is made of three main components:
1. The master regulator which sets the pilot pressure.
2. The solenoid valve which will open or close the system 

when the operator actuates the switch key.

3. The slave regulator which is the main body.

(Dwg. 80177892)

The slave regulator (3) will receive the signal from the master 
regulator (1) through the solenoid valve (Fig 2). For             
pre-engage Starters (Fig 1) the signal pressure will come 
from the master regulator through the solenoid valve to the 
pilot “In” port of the air starter drive housing, giving the signal 
to engage the drive pinion into the ring gear. After engaging 
the drive pinion it will come out through the “Out” port of the 
drive housing and will go to the top cover of the slave 
regulator.

(Dwg. 80177900)

The Slave regulator using the pressure signal on top of the 
diaphragm will force the piston off its seat. That allows air to 
flow into control chamber below the diaphragm, through the 
outlet port of the RR250 valve to the starter motor. Outlet 
pressure increases in the downstream system and sensing 
chamber (under the diaphragm) and applies an upward force 
on the bottom of the diaphragm. The diaphragm and piston 
move upward. Upward movement stops when the forces 
below the diaphragm balance the force above the 
diaphragm.

(Dwg. 80177959)

(Dwg. 80177991)

2

3

1

Figure 1

Figure 2

Содержание RR250-F30

Страница 1: ...80174964 Edition 1 October 2005 Starter Relay Valve RR250 F30 Installation and Maintenance Information Save These Instructions...

Страница 2: ...air pressure before attempting to remove the Starter Relay Valve from the Receiver or before attempting to perform any maintenance on the Starter Relay Valve Never attempt to disassemble the Starter...

Страница 3: ...Dwg 80183411 2 1 2 RR250 F30 Order part number 16675845 ILLUSTRATION REQUIRED Max Inlet Pressure 30 Bar 435 psi Max Outlet Pressure 10 Bar 145 psi Max Flow 1600 dm3 s 3400 scfm Max Temperature 80 C 17...

Страница 4: ...e housing giving the signal to engage the drive pinion into the ring gear After engaging the drive pinion it will come out through the Out port of the drive housing and will go to the top cover of the...

Страница 5: ...ave regulator will be slightly higher than the working pressure at the starter In order to easily adjust the working pressure install a gauge on port 2 Dwg 80177215 The master pressure regulator is de...

Страница 6: ...5 31 Nipple 80162233 4 Diaphragm Support 38747853 32 Nipple 80162217 6 Housing 38747788 33 Adapter 38754933 9 Set Screw 80172745 Piston Kit 38750956 10 Ring 38749990 For RR250 F30 18 Bottom Cover 3874...

Страница 7: ...Hold the stem on the flats and unscrew the diaphragm support Assembly of Relay Valve Apply Parker O Lube grease to O rings 11 14 and 17 and spring 16 Clean with isopropyl alcohol and apply Loctite 242...

Страница 8: ...www irtools com 2005 Ingersoll Rand Company...

Отзывы: