15
MAINTENANCE & TROUBLESHOOTING
SECTION 9
FIGURE 11A INLET TRANSFER VALVE DETAIL
9.5-4 CHECKING THE PURGE EXHAUST VALVES
The purge exhaust valves are normally closed. They can be checked
by removing the pilot air lines to them. The valves should be closed.
Using an air nozzle and clean air, pressurize the purge exhaust valves.
The valves should open when pressurized. If valve does not open and
close, it should be rebuilt or replaced. See Section 10.4 for valve and
parts listing.
9.5-5 CHECKING THE OUTLET CHECK VALVES
This dryer uses two check valves for outlet air control. If either of the
outlet valves fails, one of the following will occur:
• A large amount of air will purge from one tower
• The outlet air flow will be blocked
If either happens, the faulty check valve must be replaced.