Ingersoll-Rand R30-37ie Скачать руководство пользователя страница 4

 

 

2 - 30 

- EN - 

INTRODUCTION 

This manual is an integral part of the dryer you bought, and must remain with the machine even if this will be resold. 

It  is  highly  recommended  that  the  qualified*personnel  for  installation  maintenance  and/or  control  will  fully  comply  with  the 

contents of this manual and the prevention and safety rules in force in the country where the system will be used. In this way, 
not only the usage of the machine will be rational, but also the service will result cost effective. 

In case your dryer will present any kind of problem, please contact your local authorized Ingersoll Rand distributor. 

Please note that, when necessary, the use of original spare parts will ensure efficiency and long duration to your dryer. 

Due to the continuous technological evolution, Ingersoll Rand reserves the right to modify the specifications contained in this 

manual without giving previous notice. 

 

SYMBOLS AND LABELS USED IN THE MANUAL AND ON THE DRYER 

 or 

 or 

 or 

 

Air inlet. 

 or 

 or 

 or 

 

Air outlet. 

 

Read  the  Operators  manual  before  attempt  to 
start  up  the  machine  and  to  perform  any  service 
operation on the dryer. 

 

Pay  particular  attention  to  components  or  systems 
under pressure. 

 

Pay  particular  attention  to  the  indications 
preceded by these symbols. 

 

Pay particular attention to hot surfaces. 

 

Installation, 

maintenance, 

and/or 

control 

operations  preceded  by  these  symbols  must  be 
performed exclusively by qualified personnel*

 

Pay particular attention to the risk of electric shock. 

 

Condensate drain point. 

 

Rotation direction of the fan. 

 

Attention: 

Before 

performing 

any 

maintenance  operation  on  this  machine, 
do  not  forget  to  disconnect  the  electric 
supply,  to  completely  discharge  air 
pressure,  and  to  refer  to  the  Operators 
manual 

 

 

 

 

* Qualified personnel must be trained and certified in accordance with local laws and regulations. 

WARRANTY 

 

The Company warrants that the equipment manufactured by it and delivered hereunder will be free of defects in material and 

workmanship  for  a  period  of  twelve  months  from  the  date  of  placing  the  Equipment  in  operation  or  eighteen  months  from  the 
date of shipment from the factory, whichever shall first occur. The Purchaser shall be obligated to promptly report any failure to 
conform  to  this  warranty,  in  writing  to  the  Company  in  said  period,  whereupon  the  Company  shall,  at  its  option,  correct  such 
nonconformity,  by  suitable  repair  to  such  equipment  or,  furnish  a  replacement  part  F.O.B.  point  of  shipment,  provided  the 
Purchaser has stored, installed, maintained and operated such Equipment in accordance with good industry practices and has 
complied  with  specific  recommendations  of  the  Company.  Accessories  or  equipment  furnished  by  the  Company,  but 
manufactured  by  others,  shall  carry  whatever  warranty  the  manufacturers  have  conveyed  to  the  Company  and  which  can  be 
passed on to the Purchaser. The Company shall not be liable for any repairs, replacements, or adjustments to the Equipment or 
any costs of labor performed by the Purchaser or others without Company's prior written approval. 

The effects of corrosion, erosion and normal wear and tear are specifically excluded. Performance warranties are limited to 

those  specifically  stated  within  the  Company's  proposal.  Unless  responsibility  for  meeting  such  performance  warranties  are 
limited to specified tests, the Company's obligation shall be to correct in the manner and for the period of time provided above. 

THE COMPANY MAKES NO OTHER WARRANTY OR REPRESENTATION OF ANY KIND WHATSOEVER, EXPRESSED 

OR  IMPLIED,  EXCEPT  THAT  OF  TITLE,  AND  ALL  IMPLIED WARRANTIES  OF  MERCHANTABILITY  AND  FITNESS  FOR  A 
PARTICULAR PURPOSE, ARE HERBY DISCLAIMED. 

Cod. 710.0048.24.01 Rev0H – 02.2015

Содержание R30-37ie

Страница 1: ... EN DIRECT EXPANSION COMPRESSED AIR DRYERS Operators Manual R30 37ie R37 45 kW R55 75 kW Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 2: ...1 28 ...

Страница 3: ...Installation site 4 2 3 Installation 5 3 START UP 3 1 Before start up 5 3 2 Start up 5 4 MAINTENANCE TROUBLESHOOTING AND DISMANTLING 4 1 Maintenance 6 4 2 Troubleshooting 6 4 3 Dismantling 7 ATTACHMENTS TO THIS MANUAL A Refrigerant circuit 9 B Electric circuit diagram 10 C Technical data sheet 26 D Dryer dimensions 27 Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 4: ...lified personnel must be trained and certified in accordance with local laws and regulations WARRANTY The Company warrants that the equipment manufactured by it and delivered hereunder will be free of defects in material and workmanship for a period of twelve months from the date of placing the Equipment in operation or eighteen months from the date of shipment from the factory whichever shall fir...

Страница 5: ...tection degree IP 42 Improper grounding can result in electrical shock and can cause severe injury or death This product must be connected to a grounded metallic permanent wiring system or an equipment grounding terminal or lead on the product All grounding must be performed by a qualified electrician and comply with national and local electrical codes In the event of an electrical short circuit g...

Страница 6: ...e serious injury Use fork lift channels where provided The dryer is supplied packed into a suitable cardboard box to be always handled in an upright position using a means with a suitable lifting power see technical data IMPORTANT to lift or to move the unit follow the procedures shown here below pic 2 1 2 2 The dryer must be lifted and moved slightly After cutting straps always wear safety gloves...

Страница 7: ...ch a way that all the control instruments of the machine will result easily visible A suitably sized prefilter must be installed before the dryer Failure to install and maintain a proper prefilter will void the dryer warranty The rating for this filter must be at least 10 micron 3 START UP 3 1 BEFORE START UP Before starting the machine make sure that all operating parameters correspond to the nom...

Страница 8: ...ons must be performed by qualified personnel For maintaining the refrigerating circuit of the machine contact a refrigeration engineer TROUBLE POSSIBLE CAUSE REMEDY WATER IN THE SYSTEM No power in the line Restore the power in the line Problems with cabling Check cabling if the trouble persists replace it Compressed air inlet outlet inverted Check if the compressed air inlet outlet is connected pr...

Страница 9: ...istributor LOW PRESSURE IN THE LINE Ice formation in the evaporator Contact our Service Centre to check the gas charge Clog Check if the compressed air inlet outlet is connected properly Check if the connecting tubing is clogged in case proceed accordingly Check if any valves are closed Check the condition of any filter Air flows continuously through the condensate drainage Drainage jammed clean o...

Страница 10: ...nt EVA Evaporator F1 F2 Fuses FD Air filter 10 micron FF Filter dryer FH Air filter 0 01 micron FP Air filter 1 micron FQ Air filter 5 micron FR Drain screen FV Fan motor fuse G Grid IM Moisture indicator KM5 Contactor switch KM6 Fan contactor switch PCP Thermal protection PR Air air heat exchanger PSC Air air heat exchanger D__IT RBF Tap with strainer RR Rotalock cock RT1 Temperature probes SC He...

Страница 11: ...NT CIRCUIT Cod 713 0058 01 00 Rev 01 Models R30 37ie R37 45kW R55 75kW Condensate drain Refrigerant line Air inlet Compressed air line Air outlet Condensate drain line Equalization line Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 12: ...10 30 B WIRING DIAGRAM Cod 714 0211 01 00 Rev 0A Models R30 37ie R37 45 kW 400 3 50 Power wiring diagram Control circuit diagram Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 13: ...11 30 Terminal blocks Component layout Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 14: ...12 30 Cod 714 0199 01 00 Rev 1C Models R30 37ie R37 45 kW 460 3 60 Power wiring diagram Control circuit diagram Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 15: ...13 30 Terminal blocks Component layout Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 16: ...14 30 Cod 714 0199 02 00 Rev 00 Model R37 45 kW 230 3 60 Power wiring diagram Control circuit diagram Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 17: ...15 30 Terminal blocks Component layout Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 18: ...16 30 Cod 714 0199 03 00 Rev 00 Model R37 45 kW 380 3 60 Power wiring diagram Control circuit diagram Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 19: ...17 30 Terminal blocks Component layout Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 20: ...18 30 Cod 714 0186 01 00 Rev 0D Model R55 75 kW 400 3 50 Power wiring diagram Control circuit diagram Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 21: ...19 30 Terminal blocks Component layout Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 22: ...20 30 Cod 714 0174 01 00 Rev 1A Model R55 75 kW 460 3 60 Power wiring diagram Control circuit diagram Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 23: ...21 30 Terminal blocks Component layout Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 24: ...22 30 Cod 714 0174 02 00 Rev 1A Model R55 75 kW 230 3 60 Power wiring diagram Control circuit diagram Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 25: ...23 30 Terminal blocks Component layout Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 26: ...24 30 Cod 714 0174 03 00 Rev 0B Model R55 75 kW 380 3 60 Power wiring diagram Control circuit diagram Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 27: ...25 30 Terminal blocks Component layout Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 28: ... C 53 AMB T F 77 C 25 AMB T MIN MAX F 36 115 C 2 46 AIR W PRESS psi 109 bar 7 5 AIR PRESS MAX psi 174 bar 12 DEW POINT F 37 ISO CLASS 4 C 3 ISO CLASS 4 REF REFRIGERANT TYPE R134a LB 2 87 2 87 2 87 2 87 OZ 45 9 45 9 45 9 45 9 KG 1 30 1 30 1 30 1 30 W WEIGHT LB 236 236 236 236 KG 107 107 107 107 EVAP TEMP F 34 37 4 C 1 3 SUCTION TEMP F 35 6 61 C 2 16 DISCH PRESS psig 203 247 barg 14 17 HP SWITCH SET...

Страница 29: ... BSP 1 BSP 1 BSP DN51 DN51 DN51 DN51 AIR T F 95 C 35 AIR T MAX F 127 C 53 AMB T F 77 C 25 AMB T MIN MAX F 36 115 C 2 46 AIR W PRESS psi 109 bar 7 5 AIR PRESS MAX psi 174 bar 12 DEW POINT F 37 ISO CLASS 4 C 3 ISO CLASS 4 REF REFRIGERANT TYPE R404a LB 2 76 2 76 2 76 2 76 3 97 3 97 3 97 3 97 OZ 44 1 44 1 44 1 44 1 63 5 63 5 63 5 63 5 KG 1 25 1 25 1 25 1 25 1 8 1 8 1 8 1 8 W WEIGHT LB 231 231 231 231 ...

Страница 30: ...point RLA Nominal Current REF Refrigerant FLA Full load current W Weight LRA Locked rotor current EVAP TEMP Evaporation Temperature TOTAL A Total current SUCTION TEMP Suction Temperature CONNECTION Air connections DISCH PRESS Discharge Pressure AIR T Air inlet temperature HP SWITCH SETTING High pressure switch setting AIR T MAX Max air inlet temperature FAN PRESSURE SWITCH SETTING Fan pressure Swi...

Страница 31: ...29 30 R55 75 kW 609 997 136 5 AIR OUTLET 180 77 40 80 AIR INLET 108 37 644 Cod 710 0048 24 01 Rev0H 02 2015 ...

Страница 32: ......

Отзывы: