background image

Page 2 of 8 

PH30F-XXX-XXX-C (en)

WARNING

 EXCESSIVE AIR PRESSURE. Can cause per-

sonal injury, pump damage or property damage.
Do not exceed the maximum inlet air pressure as 
stated on the pump model plate.
Be sure material hoses and other components are 
able to withstand fluid pressures developed by this 
pump. Check all hoses for damage or wear. Be certain 
dispensing device is clean and in proper working con-
dition.

WARNING

 STATIC SPARK. Can cause explosion result-

ing in severe injury or death. Ground pump and 
pumping system.
Use the pump grounding screw terminal provided. 
Use ARO® part no. 66885-1 ground kit or connect a 
suitable ground wire (12 ga. min.) to a good earth 
ground source.
Secure pump, connections and all contact points to 
avoid vibration and generation of contact or static 
spark.
Consult local building codes and electrical codes for 
specifi c grounding requirements.
After grounding, periodically verify continuity of 
electrical path to ground. Test with an ohmmeter 
from each component (e.g., hoses, pump, clamps, con-
tainer, spray gun, etc.) to ground to insure continuity. 
Ohmmeter should show 0.1 ohms or less.
Submerse the outlet hose end, dispensing valve or 
device in the material being dispensed if possible. 
(Avoid free streaming of material being dispensed.)
Use hoses incorporating a static wire.
Use proper ventilation.
Keep infl ammables away from heat, open fl ames and 
sparks.
Keep containers closed when not in use.

WARNING

 Pump exhaust may contain contaminants. 

Can cause severe injury. Pipe exhaust away from work 
area and personnel.
In the event of a diaphragm rupture, material can be 
forced out of the air exhaust muffl

  er.

Pipe the exhaust to a safe remote location when 
pumping hazardous or infl ammable materials.
Use a grounded 1” minimum i.d. hose between the 
pump and the muffl

  er.

WARNING

 HAZARDOUS PRESSURE. Can result in seri-

ous injury or property damage. Do not service or 
clean pump, hoses or dispensing valve while the sys-
tem is pressurized.
Disconnect air supply line and relieve pressure from 
the system by opening dispensing valve or device and 
/ or carefully and slowly loosening and removing out-
let hose or piping from pump.

WARNING

 HAZARDOUS MATERIALS. Can cause serious 

injury or property damage. Do not attempt to return 
a pump to the factory or service center that contains 
hazardous material. Safe handling practices must 
comply with local and national laws and safety code 
requirements.

y

y

y

y

y

y

y

y

y

y

y

y

y

y

y

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

Obtain Material Safety Data Sheets on all materials 
from the supplier for proper handling instructions.

WARNING

 EXPLOSION HAZARD. Models containing 

aluminum parts cannot be used with 1,1,1-trichlo-
roethane, methylene chloride or other halogenated 
hydrocarbon solvents which may react and explode.
Check pump motor section, fl uid caps, manifolds and 
all wetted parts to assure compatibility before using 
with solvents of this type.

WARNING

 MISAPPLICATION HAZARD. Do not use 

models containing aluminum wetted parts with food 
products for human consumption. Plated parts can 
contain trace amounts of lead.

CAUTION

 Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 
flushed or recirculated. Chemical compatibility may 
change with temperature and concentration of the 
chemical(s) within the substances being pumped, 
fl ushed or circulated. For specifi c fl uid compatibility, 
consult the chemical manufacturer.

CAUTION

 Maximum temperatures are based on 

mechanical stress only. Certain chemicals will signifi -
cantly reduce maximum safe operating temperature. 
Consult the chemical manufacturer for chemical com-
patibility and temperature limits. Refer to PUMP DATA 
on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment 

have been trained for safe working practices, under-
stand it’s limitations, and wear safety goggles / equip-
ment when required.

CAUTION

 Do not use the pump for the structural sup-

port of the piping system. Be certain the system com-
ponents are properly supported to prevent stress on 
the pump parts.
Suction and discharge connections should be flex-
ible connections (such as hose), not rigid piped, 
and should be compatible with the substance being 
pumped.

CAUTION

 Prevent unnecessary damage to the pump. 

Do not allow pump to operate when out of material 
for long periods of time.
Disconnect air line from pump when system sits idle 
for long periods of time.

CAUTION

 Use only genuine ARO replacement parts to 

assure compatible pressure rating and longest service 
life.

NOTICE

 Replacement warning labels are available 

upon request: “Static Spark & Diaphragm Rupture” pn 
\ 94080.

WARNING

  = Hazards or unsafe practices which 

could result in severe personal injury, 
death or substantial property damage.

CAUTION

  = Hazards or unsafe practices which 

could result in minor personal injury, 
product or property damage.

NOTICE

  = Important installation, operation or 

maintenance information.

y

y

y

y

EXCESSIVE AIR PRESSURE
STATIC SPARK

HAZARDOUS MATERIALS
HAZARDOUS PRESSURE

Содержание PH30F-XXX-XXX-C

Страница 1: ...0 to 280 F 51 to 138 C Hytrel 20 to 150 F 29 to 66 C Nitrile 10 to 180 F 12 to 82 C Polypropylene 35 to 175 F 2 to 79 C Santoprene 40 to 225 F 40 to 107 C PTFE 40 to 225 F 4 to 107 C Viton 40 to 350 F...

Страница 2: ...y y y y y y OPERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE Obtain Material Safety Data Sheets on all materials from the supplier for pr...

Страница 3: ...o air cap item 68 only diaphragm bead groove Use ONLY 1 wrap of sealant DO NOT overlap seam Fill seam with heavy duty anearobic sealant Seam to be located between bolt positions 1 and 3 refer to Torqu...

Страница 4: ...o 60 Inlet Manifold PH30F AXX XXX C 1 94216 1 SS PH30F BXX XXX C 1 94216 2 SS Item Description size Qty Part No Mtl 61 Outlet Manifold PH30F AXX XXX C 1 94704 1 SS PH30F BXX XXX C 1 94704 2 SS 68 Air...

Страница 5: ...ds which contact pump case when using stainless steel fasteners k Apply 1 4 wide x 1 8 thick aproximately 46 long expandable PTFE Joint Sealant to air cap item 68 only diaphragm bead groove Use ONLY 1...

Страница 6: ...ert 111 spool into 135 valve block Install 137 O ring on 136 end cap and assemble end cap to 135 valve block securing with 107 end plates and 105 screws Install 140 valve insert and 141 valve plate in...

Страница 7: ...nd to threads and bolt and nut flange heads which contact pump case when us ing stainless steel fasteners Figure 3 200 138 111 139 137 136 107 236 232 233 232 176 134 133 135 105 107 166 132 243 244 1...

Страница 8: ...as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non collapsing type capable of pulling a high volume Check all joints...