Ingersoll-Rand PE10P-A0S Series Скачать руководство пользователя страница 2

Page 2 of 8 

PE10P-X-X-A0S (en)

WARNING

 EXCESSIVE AIR PRESSURE. Can cause per-

sonal injury, pump damage or property damage.

 

y

Do not exceed the maximum inlet air pressure as 

stated on the pump model plate.

 

y

Be sure material hoses and other components are able 

to withstand fluid pressures developed by this pump. 

Check all hoses for damage or wear. Be certain dispens-

ing device is clean and in proper working condition.

WARNING

 STATIC SPARK. Can cause explosion re-

sulting in severe injury or death. Ground pump and 

pumping system.

 

y

Sparks can ignite flammable material and vapors.

 

y

The pumping system and object being sprayed must 

be grounded when it is pumping, flushing, recirculat-

ing or spraying flammable materials such as paints, 

solvents, lacquers, etc. or used in a location where 

surrounding atmosphere is conducive to spontaneous 

combustion. Ground the dispensing valve or device, 

containers, hoses and any object to which material is 

being pumped.

 

y

Secure pump, connections and all contact points to 

avoid vibration and generation of contact or static 

spark.

 

y

Consult local building codes and electrical codes for 

specific grounding requirements.

 

y

After grounding, periodically verify continuity of 

electrical path to ground. Test with an ohmmeter from 

each component (e.g., hoses, pump, clamps, contain-

er, spray gun, etc.) to ground, to ensure continuity. 

Ohmmeter should show 0.1 ohms or less.

 

y

Submerse the outlet hose end, dispensing valve or 

device in the material being dispensed if possible. 

(Avoid free streaming of material being dispensed.)

 

y

Use hoses incorporating a static wire.

 

y

Use proper ventilation.

 

y

Keep inflammables away from heat, open flames and 

sparks.

 

y

Keep containers closed when not in use.

WARNING

 Pump exhaust may contain contaminants. 

Can cause severe injury. Pipe exhaust away from work 

area and personnel.

 

y

In the event of a diaphragm rupture, material can be 

forced out of the air exhaust muffler.

 

y

Pipe the exhaust to a safe remote location when 

pumping hazardous or inflammable materials.

 

y

Use a grounded 3/8” minimum ID hose between the 

pump and the muffler.

WARNING

 HAZARDOUS PRESSURE. Can result in se-

rious injury or property damage. Do not service or 

clean pump, hoses or dispensing valve while the sys-

tem is pressurized.

 

y

Disconnect air supply line and relieve pressure from 

the system by opening dispensing valve or device and 

/ or carefully and slowly loosening and removing out-

let hose or piping from pump.

WARNING

 HAZARDOUS MATERIALS. Can cause serious 

injury or property damage. Do not attempt to return 

a pump to the factory or service center that contains

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

  hazardous material. Safe handling practices must 

comply with local and national laws and safety code 

requirements.

 

y

Obtain Material Safety Data Sheets on all materials 

from the supplier for proper handling instructions.

WARNING

 EXPLOSION HAZARD. Models containing alu-

minum wetted parts cannot be used with 1,1,1-trichlo-

roethane, methylene chloride or other halogenated 

hydrocarbon solvents which may react and explode.

 

y

Check pump motor section, fluid caps, manifolds and 

all wetted parts to assure compatibility before using 

with solvents of this type.

WARNING

 MISAPPLICATION HAZARD. Do not use mod-

els containing aluminum wetted parts with food prod-

ucts for human consumption. Plated parts can contain 

trace amounts of lead.

CAUTION

 Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 

flushed or recirculated. Chemical compatibility may 

change with temperature and concentration of the 

chemical(s) within the substances being pumped, 

flushed or circulated. For specific fluid compatibility, 

consult the chemical manufacturer.

CAUTION

 Maximum temperatures are based on me-

chanical stress only. Certain chemicals will signifi-

cantly reduce maximum safe operating temperature. 

Consult the chemical manufacturer for chemical com-

patibility and temperature limits. Refer to PUMP DATA 

on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment 

have been trained for safe working practices, under-

stand it’s limitations, and wear safety goggles / equip-

ment when required.

CAUTION

 Do not use the pump for the structural sup-

port of the piping system. Be certain the system com-

ponents are properly supported to prevent stress on 

the pump parts.

 

y

Suction and discharge connections should be flex-

ible connections (such as hose), not rigid piped, 

and should be compatible with the substance being 

pumped.

CAUTION

 Prevent unnecessary damage to the pump. 

Do not allow pump to operate when out of material 

for long periods of time.

 

y

Disconnect air line from pump when system sits idle 

for long periods of time.

CAUTION

 Use only genuine ARO replacement parts to 

assure compatible pressure rating and longest service 

life.

NOTICE

 RE-TORQUE ALL FASTENERS BEFOREOPER-

ATION. Creep of housing and gasket materials may 

cause fasteners to loosen. Re-torque all fasteners to 

ensure against fluid or air leakage

WARNING

  = Hazards or unsafe practices which 

could result in severe personal injury, 

death or substantial property damage.

CAUTION

  = Hazards or unsafe practices which 

could result in minor personal injury, 

product or property damage.

NOTICE

  = Important installation, operation or 

maintenance information.

EXCESSIVE AIR PRESSURE

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

Содержание PE10P-A0S Series

Страница 1: ...inlet 53 0 gpm 200 6 lpm Displacement Cycle 100 psig 0 226 gal 0 86 lit Maximum Particle Size 1 8 dia 3 2 mm MaximumTemperature Limits diaphragm ball seat materials E P R EPDM 60 to 280 F 51 to 138 C...

Страница 2: ...ERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE hazardous material Safe handling practices must comply with local and national laws and saf...

Страница 3: ...ture stall resistant design modular air motor fluid sections Air operated double diaphragm pumps utilize a pressure differential in the air chambers to alternately create suction and positive fluid pr...

Страница 4: ...XT 637396 XXT 637396 XT 96146 T 2 T 96145 A 2 Sp 93282 4 T 93281 4 T XXV 637396 XXV 637396 XV 95989 3 2 V Y327 255 4 V Y327 220 4 V MANIFOLD FLUID CAP MATERIAL OPTIONS PE10P XXS XXX A0S PE10P AKS XXX...

Страница 5: ...METRIC 6 Diaphragm washer 25 30 ft lbs 33 9 40 7 Nm lubricate face with Lubriplate grease and apply Loctite 271 to threads 26 Screws 10 12 ft lbs 13 6 16 3 Nm 29 Nuts 10 12 ft lbs 13 6 16 3 Nm 131 Scr...

Страница 6: ...checks 2 Remove 121 plugs AIR MOTOR SECTION REASSEMBLY 1 Clean and lubricate parts not being replaced from service kit 2 Replace 173 O rings and assemble 121 plugs 3 Assemble 132 and 166 gaskets and...

Страница 7: ...nifold and inlet side fluid caps y y Check tightness of 6 diaphragm washer Motor blows air or stalls y y Check 176 check valve for damage or wear y y Check for restrictions in valve exhaust Low output...

Страница 8: ...mm R 14 11 32 364 0 mm V 17 32 13 3 mm DIMENSIONS A G L Q P PE10P AXS BXS 14 7 32 361 2 mm 14 27 32 376 5 mm 2 50 8 mm 2 3 8 59 7 mm 6 31 32 176 6 mm PE10P FXS XXX A0S 16 1 32 407 3 mm 16 1 32 407 0 m...

Отзывы: