 TROUBLE SHOOTING

Product discharged from exhaust outlet.

Check for diaphragm rupture.

Check tightness of (6) diaphragm screw.

Air bubbles in product discharge.

Check connections of suction plumbing.

Check“O” rings between intake manifold and inlet side  

fluid caps.

Check tightness of (6) diaphragm screw.

Motor blows air or stalls.

Check (176) check valve for damage or wear.

 Check for restrictions in valve / exhaust.

Low output volume, erratic flow, or no flow.

Check air supply.

Check for plugged outlet hose.

Check for kinked (restrictive) outlet material hose.

Check for kinked (restrictive) or collapsed inlet  

material hose.

Check for pump cavitation − suction pipe should be 

sized at least as large as the inlet thread diameter of 

the pump for proper flow if high viscosity fluids are 

being pumped. Suction hose must be a non-collaps-

ing type, capable of pulling a high vacuum.

Check all joints on the inlet manifolds and suction 

connections. These must be air tight.

Inspect the pump for solid objects lodged in the dia-

phragm chamber or the seat area.

DIMENSIONAL DATA

(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

8-5/16" 

(211.1 mm)

1" A.N.S.I. / DIN Flange

Outlet

Inlet

Air Inlet 1/4 - 18 N.P.T.

14-1/8" 

(358.5 mm)

6-31/32"

(176.6 mm)

16-1/32" 

(407.0 mm)

16-1/32"

(407.0 mm)

8-1/32"

(203.4 mm)

13-25/32"

(349.8 mm)

2-11/32"

(59.4 mm)

1/2" 

(12.7 mm)

5-1/32"

(127.6 mm)

7/16" 

(11.1 mm)

6-9/32"

(159.6 mm)

10-1/16" 

(255.3 mm)

4-1/16"

(103.0 mm)

16-1/32" 

(407.3 mm)

Figure 4

Содержание PD10E-X-X

Страница 1: ...ze 1 8 dia 3 2 mm MaximumTemperature Limits diaphragm ball seal material E P R EPDM 60 to 280 F 51 to 138 C Hytrel 20 to 150 F 29 to 66 C Nitrile 10 to 180 F 12 to 82 C Polypropylene 35 to 175 F 2 to...

Страница 2: ...mp to the factory or service center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements Obtain Material Safety Data Sheets on...

Страница 3: ...conductive and grounded Flooded suction inlet pressure must not exceed 10 p s i g 0 69 bar OPERATING INSTRUCTIONS Always flush the pump with a solvent compatible with the material being pumped if the...

Страница 4: ...T 2 T 96145 A 2 SP 93282 4 T 93281 4 T XXV 637396 XV 95989 3 2 V Y327 225 4 V Y327 220 4 V PARTS LIST PD10E X X FLUID SECTION MATERIAL CODE B Nitrile C Carbon Steel Co Copper E E P R GP Groundable Pol...

Страница 5: ...ds 26 Screws 10 12 ft lbs 13 6 16 3 Nm 29 Nuts 10 12 ft lbs 13 6 16 3 Nm 131 Screws tighten to 11 14 ft lbs 14 9 19 0 Nm NOTE DO NOT OVERTIGHTEN FASTENERS ALL FASTENERS ARE METRIC Santoprene 8 7 Teflo...

Страница 6: ...all 140 valve insert and 141 valve plate into 135 valve block NOTE Assemble 140 valve insert with dished side toward 141 valve plate Assemble 141 valve plate with part number identification toward 140...

Страница 7: ...0 4 5 Nm A 637395 7 replacement Major Valve Service Assembly is available separately which includes the following 105 4 107 2 111 132 135 136 137 138 139 140 141 166 176 2 200 233 and 236 4 Figure 3 1...

Страница 8: ...se Check for pump cavitation suction pipe should be sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a no...