Ingersoll-Rand PD10E-X-X Скачать руководство пользователя страница 2

Page 2 of 8 

PD10E-X-X (en)

EXCESSIVE AIR PRESSURE 

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

WARNING

 EXCESSIVE AIR PRESSURE. Can cause per- 

sonal injury, pump damage or property damage.

Do not exceed the maximum inlet air pressure as 

stated on the pump model plate.

Be sure material hoses and other components are able 

to withstand fluid pressures developed by this pump. 

Check all hoses for damage or wear. Be certain dispens-

ing device is clean and in proper working condition.

WARNING

 STATIC SPARK. Can cause explosion resulting in 

severe injury or death. Ground pump and pumping system. 

Sparks can ignite flammable material and vapors.  

The pumping system and object being sprayed must be 

grounded when it is pumping, flushing, recirculating or 

spraying flammable materials such as paints, solvents, 

lacquers, etc. or used in a location where surrounding 

atmosphere is conducive to spontaneous combustion. 

Ground the dispensing valve or device, containers, hos-

es and any object to which material is being pumped.

Secure pump, connections and all contact points to 

avoid vibration and generation of contact or static spark.

Consult local building codes and electrical codes for 

specific grounding requirements.

After grounding, periodically verify continuity of 

electrical path to ground. Test with an ohmmeter 

from each component (e.g., hoses, pump, clamps, con-

tainer, spray gun, etc.) to ground to insure continuity. 

Ohmmeter should show 0.1 ohms or less.

Submerse the outlet hose end, dispensing valve or 

device in the material being dispensed if possible. 

(Avoid free streaming of material being dispensed.)

Use hoses incorporating a static wire.

Use proper ventilation.

Keep inflammables away from heat, open flames and 

sparks.

Keep containers closed when not in use.

WARNING

 Pump exhaust may contain contaminants. 

Can cause severe injury. Pipe exhaust away from work 

area and personnel.

In the event of a diaphragm rupture, material can be 

forced out of the air exhaust muffler.

Pipe the exhaust to a safe remote location when 

pumping hazardous or inflammable materials.

Use a grounded 3/8” minimum i.d. hose between the 

pump and the muffler.

WARNING

 HAZARDOUS PRESSURE. Can result in 

serious injury or property damage. Do not service 

or clean pump, hoses or dispensing valve while the 

system is pressurized.

Disconnect air supply line and relieve pressure from 

the system by opening dispensing valve or device and 

/ or carefully and slowly loosening and removing out-

let hose or piping from pump.

WARNING

 HAZARDOUS MATERIALS. Can cause serious 

injury or property damage. Do not attempt to return 

a pump to the factory or service center that contains 

hazardous material. Safe handling practices must comply 

with local and national laws and safety code requirements.

Obtain Material Safety Data Sheets on all materials 

from the supplier for proper handling instructions.

WARNING

 EXPLOSION HAZARD. Models contain-

ing aluminum wetted parts cannot be used with III.-

Trichloroethane, Methylene Chloride or other Halo-

genated Hydrocarbon solvents which may react and 

explode.

Check pump motor section, fluid caps, manifolds and 

all wetted parts to assure compatibility before using 

with solvents of this type.

WARNING

 MISAPPLICATION HAZARD. Do not use 

models containing aluminum wetted parts with food 

products for human consumption. Plated parts can 

contain trace amounts of lead.

CAUTION

 Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 

flushed or recirculated. Chemical compatibility may 

change with temperature and concentration of the 

chemical(s) within the substances being pumped, 

flushed or circulated. For specific fluid compatibility, 

consult the chemical manufacturer.

CAUTION

  Maximum  temperatures  are  based 

on mechanical stress only. Certain chemicals will 

significantly  reduce  maximum  safe  operating 

temperature. Consult the chemical manufacturer for 

chemical compatibility and temperature limits. Refer 

to PUMP DATA on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment 

have  been  trained  for  safe  working  practices, 

understand it’s limitations, and wear safety goggles / 

equipment when required.

CAUTION

 Do not use the pump for the structural 

support of the piping system. Be certain the system 

components are properly supported to prevent stress 

on the pump parts.

Suction and discharge connections should be flexible 

connections (such as hose), not rigid piped, and should 

be compatible with the substance being pumped.

CAUTION

 Prevent unnecessary damage to the 

pump. Do not allow pump to operate when out of 

material for long periods of time.

Disconnect air line from pump when system sits idle 

for long periods of time.

CAUTION

 Use only genuine ARO replacement parts to 

assure compatible pressure rating and longest service life.

NOTICE

 RE-TORQUE ALL FASTENERS BEFORE 

OPERATION. Creep of housing and gasket materials 

may cause fasteners to loosen. Re-torque all fasteners 

to insure against fluid or air leakage.

WARNING

Hazards or unsafe practices which 

could result in severe personal injury, 

death or substantial property damage.

CAUTION

Hazards or unsafe practices which 

could result in minor personal injury, 

product or property damage.

NOTICE

Important installation, operation or

maintenance information.

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

Содержание PD10E-X-X

Страница 1: ...ze 1 8 dia 3 2 mm MaximumTemperature Limits diaphragm ball seal material E P R EPDM 60 to 280 F 51 to 138 C Hytrel 20 to 150 F 29 to 66 C Nitrile 10 to 180 F 12 to 82 C Polypropylene 35 to 175 F 2 to...

Страница 2: ...mp to the factory or service center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements Obtain Material Safety Data Sheets on...

Страница 3: ...conductive and grounded Flooded suction inlet pressure must not exceed 10 p s i g 0 69 bar OPERATING INSTRUCTIONS Always flush the pump with a solvent compatible with the material being pumped if the...

Страница 4: ...T 2 T 96145 A 2 SP 93282 4 T 93281 4 T XXV 637396 XV 95989 3 2 V Y327 225 4 V Y327 220 4 V PARTS LIST PD10E X X FLUID SECTION MATERIAL CODE B Nitrile C Carbon Steel Co Copper E E P R GP Groundable Pol...

Страница 5: ...ds 26 Screws 10 12 ft lbs 13 6 16 3 Nm 29 Nuts 10 12 ft lbs 13 6 16 3 Nm 131 Screws tighten to 11 14 ft lbs 14 9 19 0 Nm NOTE DO NOT OVERTIGHTEN FASTENERS ALL FASTENERS ARE METRIC Santoprene 8 7 Teflo...

Страница 6: ...all 140 valve insert and 141 valve plate into 135 valve block NOTE Assemble 140 valve insert with dished side toward 141 valve plate Assemble 141 valve plate with part number identification toward 140...

Страница 7: ...0 4 5 Nm A 637395 7 replacement Major Valve Service Assembly is available separately which includes the following 105 4 107 2 111 132 135 136 137 138 139 140 141 166 176 2 200 233 and 236 4 Figure 3 1...

Страница 8: ...se Check for pump cavitation suction pipe should be sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a no...