Operating Instructions
Lightsource LT6K
16
23201387 (03/05)
Operation and Maintenance Manua
Starting the engine
1.
Main Circuit Breaker and Lamp switches shall be
“OFF”.
2.
Turn Ignition Switch to “PREHEAT” for 5 seconds
prior to starting.
Note: In extreme cold temperatures, this may take
up to 10 seconds.
3.
Immediately turn Ignition Switch to “START”.
Note: Do NOT crank for more than 15 seconds
without allowing starter to cool for 30
seconds. If engine does not start after a few
attempts, refer to “Fault Finding” on page
29.
4.
Release Ignition Switch to “ON” after engine
continues to run.
5.
Allow the engine to warm-up for 3 to 5 minutes.
6.
Turn on main circuit breaker.
7.
Lamp Switches may now be used.
Note: The engine in this unit is protected with
sensors for high coolant temperature and
low oil pressure. Should either of these
conditions occur, the engine will
automatically stop causing a loss of power
to all lamps. Before restarting the unit,
check the fuel level and engine/radiator
thoroughly and correct the problem. The
lamps should not be restarted for
approximately fifteen (15 minutes).
Stopping the engine
1.
Turn Lamps “OFF”.
2.
Turn Main Breaker “OFF”.
3.
Turn Ignition Switch “OFF”.
Note: If lights are turned off, they should not be
restarted for 15 minutes.
Winch operation
Raising the tower
1.
Start the engine
2.
Use winch control switch to raise tower. Allow
winch to raise tower to desired height. Do not stop
winch before the tower is completely vertical and
latches are engaged.
3.
Loosen screw to rotate tower. Tighten screw after
rotating tower to desired angle.
Lowering tower
1.
Start the engine
2.
Switch lamps off.
3.
Rotate tower to home position and secure against
stop before lowering. Failure to do this may
damage latches.
4.
Tighten screw.
5.
Use winch control switch to lower the tower to
horizontal (transport) position.
6.
Insert and lock pin before moving or lifting.
WARNING
Electrical power is present upon cranking engine.
WARNING
Keep side doors closed for optimum cooling and
safety of unit while running.
WARNING
When raising and lowering tower, check that
there is no one behind the machine in the area of
the tower.
Check that no obstruction is overhead.
Before operating the winch, inspect the cable for
damage. Replace damaged cables. When
operating the winch, do NOT overcrank when
cable is tight. This will damage the cable. Do not
continue cranking winch when cable becomes
loose. This will cause the cable to unwind from
winch drum causing cable kinks and knots.
Before and during all winch operation, ensure the
area is clear of persons and obstructions over a
2m radius.
When the mast has completed its normal travel,
or is prevented from travelling, immediately
release the control switch, to avoid cable
extension.
Содержание LT6K
Страница 3: ...22545495 03 05 3 Lightsource LT6K Operation and Maintenance Manual...
Страница 13: ...Safety Lightsource LT6K 12 23201387 03 05 Operation and Maintenance Manual...
Страница 19: ...Operating Instructions Lightsource LT6K 18 23201387 03 05 Operation and Maintenance Manua...
Страница 29: ...Maintenance Lightsource LT6K 28 23201387 03 05 Operation and Maintenance Manual...
Страница 35: ...Specifications Lightsource LT6K Lightsource LT6K 34 23201387 03 05 Operation and Maintenance Manual...