27
P425AWIR (7/120), XP375AWIR (9/110),
HP375AWIR (10/105), VHP300AWIR (14/85)
COMPRESSOR
Actual free air delivery. 12,0 m
3
min
–1
(425 CFM)
(7/120) (P425AWIR)
Actual free air delivery.
10,5 m
3
min
–1
(375 CFM)
(9/110) (XP375AWIR)
Actual free air delivery.
10,5 m
3
min
–1
(375 CFM)
(10/105) (HP375AWIR)
Actual free air delivery.
8,5 m
3
min
–1
(300 CFM)
(14/85) (VHP300AWIR)
Normal operating discharge pressure.
7 bar (100 PSI)
(7/120) (P425AWIR)
Normal operating discharge pressure.
8,6 bar (125 PSI)
(9/110) (XP375AWIR)
Normal operating discharge pressure.
10,3 bar (150 PSI)
(10/105) (HP375AWIR)
Normal operating discharge pressure.
14 bar (200 PSI)
(14/85) (VHP300AWIR)
Maximum allowable pressure.
8,6 bar (125 PSI)
(7/120) (P425AWIR)
Maximum allowable pressure.
10.3 bar (150 PSI)
(9/110) (XP375AWIR)
Maximum allowable pressure.
12.1 bar (175 PSI)
(10/105) (HP375AWIR)
Maximum allowable pressure.
15.5 bar (225 PSI)
(14/85) (VHP300AWIR)
Safety valve setting.
10 bar (150 PSI)
(7/120) (P425AWIR)
Safety valve setting.
10 bar (200 PSI)
(9/110) (XP375AWIR)
Safety valve setting.
14 bar (200 PSI)
(10/105) (HP375AWIR)
Safety valve setting.
17 bar ( 250 PSI)
(14/85) (VHP300AWIR)
Maximum pressure ratio (absolute).
7 ,9 : 1
(7/120) (P425AWIR)
Maximum pressure ratio (absolute).
9, 6 : 1
(9/110) (XP375AWIR)
Maximum pressure ratio (absolute).
11, 3 : 1
(10/105) (HP375AWIR)
Maximum pressure ratio (absolute).
14, 8 : 1
(14/85) (VHP300AWIR)
Operating ambient temperature.
Whisperized
–12
C TO +49
C (1O
F TO 120
F)
Maximum discharge temperature.
120
C (248
F)
Cooling system.
Oil injection
Oil capacity.
36 litres ( 9.5 GAL)
Maximum oil system temperature.
120
C (248
F)
Maximum oil system pressure.
8,6 bar (125 PSI)
(7/120) (P425AWIR)
Maximum oil system pressure.
10.3 bar (150 PSI)
(9/110) (XP375AWIR)
Maximum oil system pressure.
12.1 bar (175 PSI)
(10/105) (HP375AWIR)
Maximum oil system pressure.
15.5 bar (225 PSI)
(14/85) (VHP300AWIR)
LUBRICATING OIL SPECIFICATION
(for the specified ambient temperatures).
ABOVE –23
C(–9
_
F)
Recommended: Pro–Tec
Approved: SAE 10W, API CF–4/CG–4
BELOW –23
C(–9
_
F)
Mandatory:
IR Performance 500
Ingersoll–Rand Pro–Tec
TM
compressor fluid is
factory–fitted, for use at all ambient temperatures above
–23
C(–9
F).
NOTE: Warranty may be extended only by continuous use of
Pro–Tec
and Ingersoll–Rand oil filters and separators.
No other oil/fluids are compatible with Pro–Tec
TM
No other oils/fluids should be mixed with Pro–Tec
TM
because the resulting mixture could cause damage to the
airend.
In the event that Pro–Tec
TM
is not available and / or the end
user needs to use an approved single grade engine oil, the
complete system including separator / receiver, cooler and
pipework must be flushed clear of the first fill fluid and new
Ingersoll–Rand oil filters installed.
When this has been completed, the following oils are approved:
a) for ambient temperatures above –23
C(–9
F),
SAE 10W, API CF–4/CG–4
b) for ambient temperatures below –23
C(–9
F),
I–R Performance 500 only.
Safety data sheets can be obtained on request from the
lubricant supplier.
For temperatures outside the specified ambient range,
consult Ingersoll–Rand.