USER MANUAL
Series HC
Reference IR - 222
Rev 3
Page 20
10/17/2013
SECTION 1:
(Continued)
1.4.6
Dryer Flow Capacities
Model Selection Chart:
MODEL
PSI:
Bar:
85
5.86
90
6.2
95
6.55
100
6.9
105
7.24
110
7.58
115
7.93
HC-3
SCFM:
Nm3/h:
262
421
274
441
287
461
301
484
313
503
327
526
342
550
HC-6
SCFM:
Nm3/h:
465
748
486
781
509
818
535
860
557
896
581
934
608
978
HC-7
SCFM:
Nm3/h:
588
945
615
989
645
1037
677
1088
705
1133
735
1182
769
1236
HC-9
SCFM:
Nm3/h:
726
1167
760
1222
796
1280
836
1344
870
1399
908
1460
950
1527
HC-14
SCFM:
Nm3/h:
1046
1682
1094
1759
1146
1842
1204
1936
1253
2014
1308
2103
1368
2199
HC-21
SCFM:
Nm3/h:
1634
2627
1709
2748
1790
2878
1880
3023
1957
3146
2042
3283
2136
3434
HC-30
SCFM:
Nm3/h:
2353
3783
2462
3958
2578
4145
2708
4354
2819
4532
2941
4728
3076
4945
HC-41
SCFM:
Nm3/h:
3203
5150
3351
5388
3509
5642
3686
5926
3837
6169
4003
6436
4187
6732
HC- 54
SCFM:
Nm3/h:
4183
6725
4376
7035
4583
7368
4814
7740
5011
8056
5228
8405
5469
8793
HC-69
SCFM:
Nm3/h:
5295
8513
5539
8905
5801
9326
6093
9796
6343
10198
6617
10638
6922
11129
HC-85
SCFM:
Nm3/h:
6537
10510
6837
10992
7161
11513
7522
12093
7830
12589
8169
13134
8545
13738
HC-103
SCFM:
Nm3/h:
7909
12716
8273
13301
8664
13929
9101
14632
9474
15232
9884
15891
10339
16622
HC-122
SCFM:
Nm3/h:
9413
15134
9846
15830
10312
16579
10832
17415
11276
18129
11764
18913
12305
19783
HC-143
SCFM:
Nm3/h:
11047
17761
11555
18577
12102
19457
12712
20438
13233
21275
13805
22195
14441
23217
HC-166
SCFM:
Nm3/h:
12812
20598
13401
21545
14035
22565
14743
23703
15347
24674
16011
25741
16748
26926
Note: Maximum operating pressure is 150 PSIG (10.34 Bar);
higher pressures available as an option. Consult factory.
Minimum Inlet Pressure
PSIG:
Bar:
85
5.86
90
6.2
95
6.55
100
6.9
105
7.24
110
7.58
115
7.93
Correction Factor
1.15 1.1 1.05 1
.96 .92 .88
CORRECTION FACTOR FOR COOLING WATER TEMPERATURE
Temperature
°F
ºC
75
24
80
27
85
29
90
32
Correction Factor
.85 .9 1.0 1.2
To correct for a cooling water temperature other than 85
F, or an operating pressure other than
100 psig, multiply dryer capacity by the correction factors listed above.
Example:
To size for an inlet flow of 2208 m^3/hr @ 6.2 Bar, using 32
C cooling water:
Multiply 2208 * (1.1) * (1.2) = 2914 Use Model HC-21
Содержание HC-103
Страница 2: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 2 10 17 2013 ...
Страница 31: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 31 10 17 2013 SECTION 4 MAINTENANCE ...
Страница 40: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 40 10 17 2013 SECTION 5 TROUBLESHOOTING FAULTS ...
Страница 50: ......
Страница 52: ......
Страница 54: ......
Страница 56: ......
Страница 57: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 45 10 17 2013 SECTION 7 AUXILIARY MANUALS IF APPLICABLE ...
Страница 69: ...SAHARA MOISTURE TRANSMITTER Instruction Manual ...
Страница 85: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 46 10 17 2013 SECTION 8 CUT SHEETS ...
Страница 94: ...Page 4 MODEL 1700TM DIMENSIONAL PRINT 050205 Model 1700 IG ...
Страница 119: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 47 10 17 2013 SECTION 9 DRAWINGS ...
Страница 120: ......
Страница 121: ......
Страница 122: ......
Страница 123: ......
Страница 124: ......
Страница 125: ......
Страница 126: ......
Страница 127: ......
Страница 128: ......