background image

4

SERVICING THE TOOL

Lubrication

Ingersoll--Rand No. 50

Ingersoll--Rand No. 100

Always use an air line lubricator with these tools.
We recommend the following Filter--Regulator--Lubricator
(FRL) Unit:

For USA use Unit Number C28--04--FKG0--28

After each eight hours of operation,

unless an air line

lubricator is used, inject 1.5 cc of Ingersoll--Rand
No. 50 Oil into the inlet of the tool and run the tool
briefly.

After each forty--eight hours of operation,

or as

experience indicates, inject about 3 cc of Ingersoll--Rand
No. 100 Grease into the Grease Fitting (11).

(Dwg. TPD905--2)

F

L

R

Main Line(s) Inner Ø

to be 3X Size of

Air Tool’s Inlet Ø

To Air

System

To Air

Tool

Lubricator

Emergency

Shut--Off

Valve

Regulator

Filter

Compressor

FRL

Drain Regularly

Branch Line(s) Inner Ø

to be 2X Size of

Air Tool’s Inlet Ø

SPECIFICATIONS

Model

Type of

Handle

Drive

Impacts

per min.

Recommended

Torque Range

H

Sound Level

dB (A)

Vibrations

Level

in.

ft--lbs (Nm)

Pressure

Power

m/s

2

IR--C212

pistol

3/8” sq. dr.,

ring--type

retainer

1500

20--125 (27--170)

97.5

110.5

2.7

Отзывы: