background image

5

PLACING TOOL IN SERVICE

Disposal of Worn Out Battery

Return the worn out Battery to the distributor from which
it was purchased as soon as the post charging battery life
becomes too short for practical use.

Charging the Battery

Use only the models of Battery Chargers listed in the
section of this form PLACING THE TOOL IN 
SERVICE, for charging the BP10P3–950 Battery.

For continuos service of the Impulse Tool, a spare Battery
should be kept on hand for alternate use.
During the initial charge or after the Battery has not been
used for a long time, the Battery may not take a full
charge.  If this occurs, use the Battery in the Impulse Tool
again before resuming the charging cycle.  It should then
accept a full charge.

1.

Disengage the Battery by depressing the button on
the Battery to release the latch and then pulling the
Battery out the bottom of the housing handle.

2.

Insert the AC power cord of the Battery Charger into
the power receptacle.

3.

Insert the Battery into the charger making sure that
the positive (+) and negative (–) sides are properly
oriented.  The Charger has a series of lines embossed
to match the lines  on the battery when the Battery is
properly positioned.  Additionally, the Battery will
not fully enter the Charger if the orientation is off
180

_

 from correct insertion.  When properly inserted,

the power indicator light will remain red.

4.

When the Battery is fully charged, the red light will
flash in half second intervals.

If the light blinks  in one tenth or two tenths of a
second intervals, a charging problem exists. 
Consult the Battery Charger Manual for probable
causes and solutions.

Changing Rotational Direction

Before operating the Impulse Wrench, make certain the
socket is rotating in the direction required for the job 
application.

Do not attempt to change rotational direction while the
tool is running or without releasing the Trigger Switch.
Failure to do so can cause damage to the Trigger
Switch.

The forward/reverse lever is located at the top of the 
Trigger Switch.  To change direction, proceed as follows:

1.

Hold the tool in a normal manner and release the
Trigger Switch.

2.

For right hand or clockwise rotation, push the lever
completely to the right.

3.

For left hand or counterclockwise rotation, push the
lever completely to the left.

  HOW TO ORDER AN IMPULSE WRENCH  

Model

Free Speed

Recommended Torque Range

Soft Draw

Hard Slam

in–lb

Nm

in–lb

Nm

PISTOL GRIP with 1/4” INSERT BIT CHUCK

BP109PQ1

2200

80–142

9–16

97–168

11–19

PISTOL GRIP with 3/8” SQUARE DRIVE

BP10P3

2200

80–142

9–16

97–168

11–19

Содержание BP10P3

Страница 1: ...Always wear eye protection when operating or performing maintenance on this tool Power tools can vibrate in use Vibration repetitive motions or uncomfortable positions may be harmful to your hands and...

Страница 2: ...es Inspect the tool periodically and if damaged have it repaired by an authorized service facility Inspect extension cords periodically and replace if damaged Keep handles dry clean and free from oil...

Страница 3: ...on cord must be the same number size and shape as those on the plug of the Battery Charger b The extension cord must be properly wired and in good electrical condition c The wire size must be large en...

Страница 4: ...t expose the Battery Charger to wet conditions To prevent damage to electric cord and plug disconnect Battery Charger from electrical outlet by pulling on plug rather than cord Make sure cord is locat...

Страница 5: ...y positioned Additionally the Battery will not fully enter the Charger if the orientation is off 180_ from correct insertion When properly inserted the power indicator light will remain red 4 When the...

Страница 6: ...MAINTENANCE SECTION 6 Dwg TPA1562 1...

Страница 7: ...Planet Gear Shaft Retainer BP10P3 953 BP10PQ1 EU EU 99 28 Grease Shield BP10P3 739 2A Nameplate 29 Impulse Housing Assembly 280PQ A31 for model BP10P3 BP10P3 301 30 Torque Adjustment Screw 180PQ 230...

Страница 8: ...Replacement Kit includes Fluid Syringe 52 Retaining Pin Spring 401 718 Fill Tube and 4 oz 31 mL of Replacement Fluid EQ106S K400 53 Blade Assembly 2 BP10P3 A220 Replacement Fluid 4 oz 31 mL EQ106S 40...

Страница 9: ...e Oil Plug Seal into the mechanism until it is snug 11 Using the 1 5 mm Hex Wrench turn the Torque Adjustment Screw clockwise until it stops This is the maximum torque position 12 Wipe the outside of...

Страница 10: ...e Gearing and Motor Housing 1 Remove the assembled Planetary Gear Frame 23 from the shaft of the Motor Assembly 12 and out of engagement with the Ring Gear 21 2 Remove the Rear Planet Gear Shaft Retai...

Страница 11: ...ing Gear Retaining Pin 22 into the hole formed by the two notches to keep the Ring Gear in position 9 Insert the assembled Bearing Cage small hub leading into the Front Motor Support and align the mou...

Страница 12: ...as removed proceed as follows a Insert a 1 5 mm hex wrench into the threaded hole for the Torque Adjustment Screw from the Oil Plug end of the Housing b From the opposite end of the Housing install th...

Страница 13: ...nd put grease in the central opening of the Cover Refer to Dwg TPD1289 Dwg TPD1289 GREASE 15 Reinstall the Cover Assembly and use a hex wrench to push it below the threads at the rear of the Housing R...

Страница 14: ...14 NOTES...

Страница 15: ...15 NOTES...

Отзывы: