OPERATING AND SAFETY PRECAUTIONS
READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE
EXCESSIVE AIR PRESSURE
STATIC SPARK
HAZARDOUS MATERIALS
HAZARDOUS PRESSURE
WARNING
EXCESSIVE AIR PRESSURE. Can cause
personal injury, pump damage or property damage.
y
Do not exceed the maximum inlet air pressure as
stated on the pump model plate.
y
Be sure material hoses and other components are able
to withstand
fl
uid pressures developed by this pump.
Check all hoses for damage or wear. Be certain dispens-
ing device is clean and in proper working condition.
WARNING
STATIC SPARK. Can cause explosion
resulting in severe injury or death. Ground pump and
pumping system.
y
Sparks can ignite
fl
ammable material and vapors.
y
The pumping system and object being sprayed must be
grounded when it is pumping,
fl
ushing, recirculating or
spraying
fl
ammable materials such as paints, solvents,
lacquers, etc. or used in a location where surrounding
atmosphere is conducive to spontaneous combustion.
Ground the dispensing valve or device, containers, hos-
es and any object to which material is being pumped.
y
Secure pump, connections and all contact points to avoid
vibration and generation of contact or static spark.
y
Consult local building codes and electrical codes for
speci
fi
c grounding requirements.
y
After grounding, periodically verify continuity of
electrical path to ground. Test with an ohmmeter from
each component (e.g., hoses, pump, clamps, con-
tainer, spray gun, etc.) to ground to ensure continuity.
Ohmmeter should show 0.1 ohms or less.
y
Submerse the outlet hose end, dispensing valve or
device in the material being dispensed if possible.
(Avoid free streaming of material being dispensed.)
y
Use hoses incorporating a static wire.
y
Use proper ventilation.
y
Keep in
fl
ammables away from heat, open
fl
ames and sparks.
y
Keep containers closed when not in use.
WARNING
Pump exhaust may contain contaminants.
Can cause severe injury. Pipe exhaust away from work
area and personnel.
y
In the event of a diaphragm rupture, material can be
forced out of the air exhaust mu
ffl
er.
y
Pipe the exhaust to a safe remote location when
pumping hazardous or in
fl
ammable materials.
y
Use a grounded 3/4” minimum i.d. hose between the
pump and the mu
ffl
er.
WARNING
HAZARDOUS PRESSURE. Can result in
serious injury or property damage. Do not service
or clean pump, hoses or dispensing valve while the
system is pressurized.
y
Disconnect air supply line and relieve pressure from
the system by opening dispensing valve or device
and / or carefully and slowly loosening and removing
outlet hose or piping from pump.
WARNING
HAZARDOUS MATERIALS. Can cause serious
injury or property damage. Do not attempt to return
a pump to the factory or service center that contains
hazardous material. Safe handling practices must comply
with local and national laws and safety code requirements.
y
Obtain Material Safety Data Sheets on all materials
from the supplier for proper handling instructions.
WARNING
EXPLOSION HAZARD.Models containing
aluminum wetted parts cannot be used with III.-
Trichloroethane,Methylene Chloride or other
Halogenated Hydrocarbon solvents which may react
and explode.
y
Check pump motor section,
fl
uid caps, manifolds and
all wetted parts to assure compatibility before using
with solvents of this type.
WARNING
MISAPPLICATION HAZARD. Do not use
models containing aluminum wetted parts with food
products for human consumption. Plated parts can
contain trace amounts of lead.
CAUTION
Verify the chemical compatibility of the
pump wetted parts and the substance being pumped,
fl
ushed or recirculated. Chemical compatibility may
change with temperature and concentration of the
chemical(s) within the substances being pumped,
fl
ushed or circulated. For speci
fi
c
fl
uid compatibility,
consult the chemical manufacturer.
CAUTION
Maximum temperatures are based
on mechanical stress only. Certain chemicals will
signi
fi
cantly reduce maximum safe operating
temperature. Consult the chemical manufacturer for
chemical compatibility and temperature limits. Refer
to PUMP DATA on page 1 of this manual.
CAUTION
Be certain all operators of this equipment
have been trained for safe working practices,
understand it’s limitations, and wear safety goggles /
equipment when required.
CAUTION
Do not use the pump for the structural
support of the piping system. Be certain the system
components are properly supported to prevent stress
on the pump parts.
y
Suction and discharge connections should be
fl
exible
connections (such as hose), not rigid piped, and should
be compatible with the substance being pumped.
CAUTION
Prevent unnecessary damage to the
pump. Do not allow pump to operate when out of
material for long periods of time.
y
Disconnect air line from pump when system sits idle
for long periods of time.
CAUTION
Use only genuine ARO
®
replacement parts to
assure compatible pressure rating and longest service life.
NOTICE
TORQUE ALL FASTENERS BEFORE OPERATION.
Creep of housing and gasket materials may cause fasteners
to loosen. Torque all fasteners to ensure against
fl
uid or
air leakage.
WARNING
=
Hazards or unsafe practices which
could result in severe personal injury,
death or substantial property damage.
CAUTION
=
Hazards or unsafe practices which
could result in minor personal injury,
product or property damage.
NOTICE
=
Important installation, operation or
maintenance information.
Содержание ARO PX15P A Series
Страница 11: ...PX15P XXX XXX AXXX en Page 11 of 12...
Страница 12: ...Page 12 of 12 PX15P XXX XXX AXXX en PN 97999 1055...