background image

PX15P-XXX-XXX-AXXX (en) 

Page 3 of 12

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE

EXCESSIVE AIR PRESSURE

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

WARNING

 

EXCESSIVE AIR PRESSURE. Can cause 

personal injury, pump damage or property damage.

 

y

Do not exceed the maximum inlet air pressure as 

stated on the pump model plate.

 

y

Be sure material hoses and other components are able 

to withstand  

fl

uid pressures developed by this pump. 

Check all hoses for damage or wear. Be certain dispens-

ing device is clean and in proper working condition.

WARNING

 

STATIC SPARK. Can cause explosion 

resulting in severe injury or death. Ground pump and 

pumping system.

 

y

Sparks can ignite 

fl

ammable material and vapors.  

 

y

The pumping system and object being sprayed must be 

grounded when it is pumping, 

fl

ushing, recirculating or 

spraying 

fl

ammable materials such as paints, solvents, 

lacquers, etc. or used in a location where surrounding 

atmosphere is conducive to spontaneous combustion. 

Ground the dispensing valve or device, containers, hos-

es and any object to which material is being pumped.

 

y

Secure pump, connections and all contact points to avoid 

vibration and generation of contact or static spark.

 

y

Consult local building codes and electrical codes for 

speci

fi

c grounding requirements.

 

y

After grounding, periodically verify continuity of 

electrical path to ground. Test with an ohmmeter from 

each component (e.g., hoses, pump, clamps, con-

tainer, spray gun, etc.) to ground to ensure continuity. 

Ohmmeter should show 0.1 ohms or less.

 

y

Submerse the outlet hose end, dispensing valve or 

device in the material being dispensed if possible. 

(Avoid free streaming of material being dispensed.)

 

y

Use hoses incorporating a static wire.

 

y

Use proper ventilation.

 

y

Keep in

fl

ammables away from heat, open 

fl

ames and sparks.

 

y

Keep containers closed when not in use.

WARNING

 

Pump exhaust may contain contaminants. 

Can cause severe injury. Pipe exhaust away from work 

area and personnel.

 

y

In the event of a diaphragm rupture, material can be 

forced out of the air exhaust mu

ffl

er.

 

y

Pipe the exhaust to a safe remote location when 

pumping hazardous or in

fl

ammable materials.

 

y

Use a grounded 3/4” minimum i.d. hose between the 

pump and the mu

ffl

er.

WARNING

 

HAZARDOUS PRESSURE. Can result in 

serious injury or property damage. Do not service 

or clean pump, hoses or dispensing valve while the 

system is pressurized.

 

y

Disconnect air supply line and relieve pressure from 

the system by opening dispensing valve or device 

and / or carefully and slowly loosening and removing 

outlet hose or piping from pump.

WARNING

 

HAZARDOUS MATERIALS. Can cause serious 

injury or property damage. Do not attempt to return 

a pump to the factory or service center that contains 

hazardous material. Safe handling practices must comply 

with local and national laws and safety code requirements.

 

y

Obtain Material Safety Data Sheets on all materials 

from the supplier for proper handling instructions.

WARNING

 

EXPLOSION HAZARD.Models containing 

aluminum wetted parts cannot be used with III.-

Trichloroethane,Methylene Chloride or other 

Halogenated Hydrocarbon solvents which may react 

and explode.

 

y

Check pump motor section, 

fl

uid caps, manifolds and 

all wetted parts to assure compatibility before using 

with solvents of this type.

WARNING

 

MISAPPLICATION HAZARD. Do not use 

models containing aluminum wetted parts with food 

products for human consumption. Plated parts can 

contain trace amounts of lead.

CAUTION

 Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 

fl

ushed or recirculated. Chemical compatibility may 

change with temperature and concentration of the 

chemical(s) within the substances being pumped, 

fl

ushed or circulated. For speci

fi

fl

uid compatibility, 

consult the chemical manufacturer.

CAUTION

 Maximum temperatures are based 

on mechanical stress only. Certain chemicals will 

signi

fi

cantly reduce maximum safe operating 

temperature. Consult the chemical manufacturer for 

chemical compatibility and temperature limits. Refer 

to PUMP DATA on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment 

have been trained for safe working practices, 

understand it’s limitations, and wear safety goggles / 

equipment when required.

CAUTION

 Do not use the pump for the structural 

support of the piping system. Be certain the system 

components are properly supported to prevent stress 

on the pump parts.

 

y

Suction and discharge connections should be 

fl

exible 

connections (such as hose), not rigid piped, and should 

be compatible with the substance being pumped.

CAUTION

 Prevent unnecessary damage to the 

pump. Do not allow pump to operate when out of 

material for long periods of time.

 

y

Disconnect air line from pump when system sits idle 

for long periods of time.

CAUTION

 

Use only genuine ARO

®

 replacement parts to 

assure compatible pressure rating and longest service life.

NOTICE

 TORQUE ALL FASTENERS BEFORE OPERATION.

  Creep of housing and gasket materials may cause fasteners

  to loosen. Torque all fasteners to ensure against 

fl

uid or

  air leakage.

WARNING

=

Hazards or unsafe practices which 

could result in severe personal injury, 

death or substantial property damage.

CAUTION

=

Hazards or unsafe practices which 

could result in minor personal injury, 

product or property damage.

NOTICE

=

Important installation, operation or

maintenance information.

Содержание ARO PX15P A Series

Страница 1: ...9 32 kgs PX15P YKS XXX AXXX 55 94 lbs 25 37 kgs PX15P YPS XXX AXXX 42 30 lbs 19 19 kgs PX15E FES XXX AXXX 43 14 lbs 19 57 kgs Maximum Air Inlet Pressure 120 psig 8 3 bar Maximum Material Inlet Pressur...

Страница 2: ...oid 240 VAC 220 VAC AND 120 VDC G Solenoid 12 VDC ATEX IECEx H Solenoid 24 VDC ATEX IECEx K Solenoid 220VAC ATEX IECEx N Solenoid with no Coil P Ported Motor No major valve NOTICE All possible options...

Страница 3: ...outlet hose or piping from pump WARNING HAZARDOUS MATERIALS Can cause serious injury or property damage Do not attempt to return a pump to the factory or service center that contains hazardous materi...

Страница 4: ...connections should not be rigid piped and must be compatible with the material being pumped y Secure the diaphragm pump legs to a suitable surface level and flat to ensure against damage by vibration...

Страница 5: ...AP MATERIAL PX15X XXS XXX AXXX PX15P FKS PX15P YKS PX15P FPS PX15P YPS PX15E FES Item Description Qty Part no Mtl Part no Mtl Part no Mtl Part no Mtl Part no Mtl 6 Diaphragm Washer 2 95975 2 K 95975 2...

Страница 6: ...when using stainless steel fasteners Apply Lubriplate FML 2 grease to all O rings U Cups mating parts COLOR CODE Diaphragm Ball Material 26 PX15P YXS XXX AXXX 24 61 PX15P YXS XXX AXXX 60 22 19 21 33...

Страница 7: ...ecifica tion block on view y Torque fasteners following restart y SERVICE TOOLS To aid in the installation of 168 O rings onto the 167 pilot piston use tool 204130 T available from ARO PILOT VALVE DIS...

Страница 8: ...40 138 103 118 121 173 168 171 172 169 121 174 111 139 137 136 107 236 107 135 134 43 Item 43 optional PD15E XXX XXX AXXX PE15E XXX XXX AXXX 133 133 134 Insert screwdriver here to remove 233 adapter p...

Страница 9: ...in valve exhaust Low output volume y Check air supply y Check for plugged outlet hose y Check for kinked restrictive outlet material hose y Check for kinked restrictive or collapsed inlet material ho...

Страница 10: ...X PX15E XXX XXX AXXX PX15P YXS XXX AXXX DIMENSIONS A See below B 21 15 32 545 3 mm C 14 15 16 379 4 mm D 3 9 32 83 3 mm E See below F 10 1 2 266 3 mm G see below H 8 11 16 220 7 mm J 10 1 32 254 8 mm...

Страница 11: ...PX15P XXX XXX AXXX en Page 11 of 12...

Страница 12: ...Page 12 of 12 PX15P XXX XXX AXXX en PN 97999 1055...

Отзывы: