Ingersoll-Rand ARO PX03P Series Скачать руководство пользователя страница 4

Page 4 of 12 

PX03P-XXX-XXX-AXXX (en)

 Viton

®

 and Hytrel

®

 are registered trademarks of the DuPont

®

  Company  Loctite

®

 is a registered trademark of Henkel Loctite Corporation 

  Santoprene

®

 is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P.  Lubriplate

®

 is a registered trademark of Lubriplate Division (Fiske Brothers Refining Company)   

GENERAL DESCRIPTION

The ARO diaphragm pump offers high volume delivery even 

at low air pressure and a broad range of material compatibility 

options available. Refer to the model and option chart. ARO 

pumps feature stall resistant design, modular air motor / fluid 

sections. 

Air operated double diaphragm pumps utilize a pressure dif-

ferential in the air chambers to alternately create suction and 

positive fluid pressure in the fluid chambers, ball checks insure 

a positive flow of fluid. 

Pump cycling will begin as air pressure is applied and it will 

continue to pump and keep up with the demand. It will build 

and maintain line pressure and will stop cycling once maxi-

mum line pressure is reached (dispensing device closed) and 

will resume pumping as needed.

AIR AND LUBE REQUIREMENTS

WARNING

 EXCESSIVE AIR PRESSURE. Can cause pump 

damage, personal injury or property damage.

A filter capable of filtering out particles larger than 50 

microns should be used on the air supply. There is no 

lubrication required other than the “O” ring lubricant which is 

applied during assembly or repair.

If lubricated air is present, make sure that it is compatible 

with the “O” rings and seals in the air motor section of the 

pump.

OPERATING INSTRUCTIONS

Always flush the pump with a solvent compatible with 

the material being pumped if the material being pumped 

is subject to “setting up” when not in use for a period of 

time.

Disconnect the air supply from the pump if it is to be inac-

tive for a few hours.

The outlet material volume is governed not only by the 

air supply but also by the material supply available at the 

inlet. The material supply tubing should not be too small 

or restrictive. Be sure not to use hose which might col-

lapse.

When the diaphragm pump is used in a forced-feed 

(flooded inlet) situation, it is recommended that a Check 

Valve” be installed at the air inlet.

Secure the diaphragm pump legs to a suitable surface to 

insure against damage by vibration.

MAINTENANCE

Certain ARO “Smart Parts” are indicated which should be 

available for fast repair and reduction of down time.

Provide a clean work surface to protect sensitive internal 

moving parts from contamination from dirt and foreign 

matter during service disassembly and reassembly.

Keep good records of service activity and include pump 

in preventive maintenance program.

Service Kits are available to service two separate Dia-

phragm Pump functions: 1. AIR SECTION, 2. FLUID SEC-

TION. The Fluid Section is divided further to match typical 

active MATERIAL OPTIONS.

Содержание ARO PX03P Series

Страница 1: ...s PX03P XRS XXX AXXX 3 50 lbs 1 59 kgs Maximum Air Inlet Pressure 100 psig 6 9 bar Maximum Material InletPressure 10 psig 0 69 bar Maximum Outlet Pressure 100 psig 6 9 bar Air Consumption 40 psig 1 cf...

Страница 2: ...ns may not be recommended Consult a representative or the factory if you have questions concerning availability G End of Stroke ATEX IECEx NEC CEC F End of Stroke feedback E End of Stroke feedback Lea...

Страница 3: ...and slowly loosening and removing out let hose or piping from pump WARNING HAZARDOUS MATERIALS Can cause serious injury or property damage Do not attempt to return a pump to the factory or service cen...

Страница 4: ...e is no lubrication required other than the O ring lubricant which is applied during assembly or repair If lubricated air is present make sure that it is compatible with the O rings and seals in the a...

Страница 5: ...96744 3 4 N PXX 96580 1 4 P XSX 96513 4 SS XLX 96744 4 4 V SXX 96537 4 SS XTX 96481 4 4 T XKX 96744 1 4 E 0XX 96745 4 P XVX 96481 3 4 V NOTE Item 19 O ring is not used with PD03P XXX 0XX AXXX seat opt...

Страница 6: ...REQUIREMENTS Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when using stainless steel fasteners Apply Lubriplate 94276 to all O rings U cups and mating par...

Страница 7: ...ch T 10 Torx screwdriver torque wrench measuring inch pounds O ring pick FLUID SECTION DISASSEMBLY Remove 61 top manifold Remove 19 O rings 21 seats and 22 balls Remove 60 bottom manifold Remove 19 O...

Страница 8: ...spool LIPS MUST FACE EACH OTHER Assemble 137 O rings to 136 large plug Assemble 137 and 166 O rings to 107 small plug Insert 111 spool into 136 large plug then insert 136 large plug into 135 valve blo...

Страница 9: ...so that the balls will check by gravity Check for pump cavitation suction pipe should be sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are...

Страница 10: ...PX03P XXX XXX AXXX en Page 11 of 12...

Страница 11: ...Page 12 of 12 PX03P XXX XXX AXXX en PN 97999 1180...

Отзывы: