Ingersoll-Rand ARO PX03P Series Скачать руководство пользователя страница 3

PX03P-XXX-XXX-AXXX (en)

Page 3 of 12

 

Page 3 of 12

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

EXCESSIVE AIR PRESSURE 

S TATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

WARNING

 EXCESSIVE AIR PRESSURE. Can cause per- 

sonal injury, pump damage or property damage.

Do not exceed the maximum inlet air pressure as 

stated on the pump model plate.

Be sure material hoses and other components are able 

to withstand fluid pressures developed by this pump. 

Check all hoses for damage or wear. Be certain dispens-

ing device is clean and in proper working condition.

WARNING

  STATIC  SPARK.  Can  cause  explosion 

resulting in severe injury or death. Ground pump and 

pumping system.

PX03P-XDS-XXX-AXXX and PX03P-XES-XXX-AXXX 

Groundable Acetal pumps: Use the pump ground lug 

provided. Connect to a 12 ga. (minimum) wire (kit is 

included) to a good earth ground source.

Sparks can ignite flammable material and vapors.  

The pumping system and object being sprayed must be 

grounded when it is pumping, flushing, recirculating or 

spraying flammable materials such as paints, solvents, 

lacquers, etc. or used in a location where surrounding 

atmosphere is conducive to spontaneous combustion. 

Ground the dispensing valve or device, containers, hos-

es and any object to which material is being pumped.

Secure pump, connections and all contact points to avoid 

vibration and generation of contact or static spark.

Consult local building codes and electrical codes for 

specific grounding requirements.

After grounding, periodically verify continuity of 

electrical path to ground. Test with an ohmmeter 

from each component (e.g., hoses, pump, clamps, con-

tainer, spray gun, etc.) to ground to insure continuity. 

Ohmmeter should show 0.1 ohms or less.

Submerse the outlet hose end, dispensing valve or 

device in the material being dispensed if possible. 

(Avoid free streaming of material being dispensed.)

Use hoses incorporating a static wire.

Use proper ventilation.

Keep inflammables away from heat, open flames and 

sparks.

Keep containers closed when not in use.

WARNING

 Pump exhaust may contain contaminants. 

Can cause severe injury. Pipe exhaust away from work 

area and personnel.

In the event of a diaphragm rupture, material can be 

forced out of the air exhaust muffler.

Pipe the exhaust to a safe remote location when 

pumping hazardous or inflammable materials.

Use a grounded 3/8” minimum i.d. hose between the 

pump and the muffler.

WARNING

 HAZARDOUS PRESSURE. Can result in 

serious injury or property damage. Do not service 

or clean pump, hoses or dispensing valve while the 

system is pressurized.

Disconnect air supply line and relieve pressure from 

the system by opening dispensing valve or device and 

/ or carefully and slowly loosening and removing out-

let hose or piping from pump.

WARNING

 HAZARDOUS MATERIALS. Can cause serious 

injury or property damage. Do not attempt to return 

a pump to the factory or service center that contains 

hazardous material. Safe handling practices must comply 

with local and national laws and safety code requirements.

Obtain Material Safety Data Sheets on all materials 

from the supplier for proper handling instructions.

WARNING

 EXPLOSION HAZARD. Models containing 

aluminum wetted parts cannot be used with 1,1,1-

trichloroethane, methylene chloride or other 

halogenated hydrocarbon solvents which may react 

and explode.

Check pump motor section, fluid caps, manifolds and 

all wetted parts to assure compatibility before using 

with solvents of this type.

CAUTION

 Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 

flushed or recirculated. Chemical compatibility may 

change with temperature and concentration of the 

chemical(s) within the substances being pumped, 

flushed or circulated. For specific fluid compatibility, 

consult the chemical manufacturer.

CAUTION

  Maximum  temperatures  are  based 

on mechanical stress only. Certain chemicals will 

significantly  reduce  maximum  safe  operating 

temperature. Consult the chemical manufacturer for 

chemical compatibility and temperature limits. Refer 

to PUMP DATA on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment 

have  been  trained  for  safe  working  practices, 

understand it’s limitations, and wear safety goggles / 

equipment when required.

CAUTION

 Do not use the pump for the structural 

support of the piping system. Be certain the system 

components are properly supported to prevent stress 

on the pump parts.

Suction and discharge connections should be flex-

ible connections (such as hose), not rigid piped, 

and should be compatible with the substance being 

pumped.

CAUTION

 Prevent unnecessary damage to the 

pump. Do not allow pump to operate when out of 

material for long periods of time.

Disconnect air line from pump when system sits idle 

for long periods of time.

CAUTION

 Use only genuine ARO

®

 replacement parts 

to assure compatible pressure rating and longest 

service life.

NOTICE

 Install the pump in the vertical position. 

The pump may not prime properly if the balls do not 

check by gravity upon start-up.

NOTICE

 RE-TORQUE ALL FASTENERS BEFORE 

OPERATION. Creep of housing and gasket materials 

may cause fasteners to loosen. Re-torque all fasteners 

to insure against fluid or air leakage.

NOTICE

 Replacement warning labels are available 

upon request: Static Spark” pn \ 93616-1, Diaphragm 

Rupture” pn \ 93122.

WARNING

=

Hazards or unsafe practices which 

could result in severe personal injury, 

death or substantial property dam-

age.

CAUTION

=

Hazards or unsafe practices which 

could result in minor personal injury, 

product or property damage.

NOTICE

=

Important installation, operation or

maintenance information.

Содержание ARO PX03P Series

Страница 1: ...s PX03P XRS XXX AXXX 3 50 lbs 1 59 kgs Maximum Air Inlet Pressure 100 psig 6 9 bar Maximum Material InletPressure 10 psig 0 69 bar Maximum Outlet Pressure 100 psig 6 9 bar Air Consumption 40 psig 1 cf...

Страница 2: ...ns may not be recommended Consult a representative or the factory if you have questions concerning availability G End of Stroke ATEX IECEx NEC CEC F End of Stroke feedback E End of Stroke feedback Lea...

Страница 3: ...and slowly loosening and removing out let hose or piping from pump WARNING HAZARDOUS MATERIALS Can cause serious injury or property damage Do not attempt to return a pump to the factory or service cen...

Страница 4: ...e is no lubrication required other than the O ring lubricant which is applied during assembly or repair If lubricated air is present make sure that it is compatible with the O rings and seals in the a...

Страница 5: ...96744 3 4 N PXX 96580 1 4 P XSX 96513 4 SS XLX 96744 4 4 V SXX 96537 4 SS XTX 96481 4 4 T XKX 96744 1 4 E 0XX 96745 4 P XVX 96481 3 4 V NOTE Item 19 O ring is not used with PD03P XXX 0XX AXXX seat opt...

Страница 6: ...REQUIREMENTS Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when using stainless steel fasteners Apply Lubriplate 94276 to all O rings U cups and mating par...

Страница 7: ...ch T 10 Torx screwdriver torque wrench measuring inch pounds O ring pick FLUID SECTION DISASSEMBLY Remove 61 top manifold Remove 19 O rings 21 seats and 22 balls Remove 60 bottom manifold Remove 19 O...

Страница 8: ...spool LIPS MUST FACE EACH OTHER Assemble 137 O rings to 136 large plug Assemble 137 and 166 O rings to 107 small plug Insert 111 spool into 136 large plug then insert 136 large plug into 135 valve blo...

Страница 9: ...so that the balls will check by gravity Check for pump cavitation suction pipe should be sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are...

Страница 10: ...PX03P XXX XXX AXXX en Page 11 of 12...

Страница 11: ...Page 12 of 12 PX03P XXX XXX AXXX en PN 97999 1180...

Отзывы: