background image

Page 2 of 12 

PP20A-XXX-XXX (en)

WARNING

 EXCESSIVE AIR PRESSURE. Can cause per-

sonal injury, pump damage or property damage.
Do not exceed the maximum inlet air pressure as 
stated on the pump model plate.
Be sure material hoses and other components are able 
to withstand fl uid pressures developed by this pump. 
Check all hoses for damage or wear. Be certain dispens-
ing device is clean and in proper working condition.

WARNING

 STATIC SPARK. Can cause explosion result-

ing in severe injury or death. Ground pump and 
pumping system.
Use the pump grounding screw terminal provided. 
Use ARO® part no. 94829 ground kit or connect a suit-
able ground wire (12 ga. minimum) to a good earth 
ground source.
Secure pump, connections and all contact points to 
avoid vibration and generation of contact or static 
spark.
Consult local building codes and electrical codes for 
specifi c grounding requirements.
After grounding, periodically verify continuity of 
electrical path to ground. Test with an ohmmeter 
from each component (e.g., hoses, pump, clamps, con-
tainer, spray gun, etc.) to ground to insure continuity. 
Ohmmeter should show 0.1 ohms or less.
Submerse the outlet hose end, dispensing valve or 
device in the material being dispensed if possible. 
(Avoid free streaming of material being dispensed.)
Use hoses incorporating a static wire.
Use proper ventilation.
Keep infl ammables away from heat, open fl ames and 
sparks.
Keep containers closed when not in use.

WARNING

 Pump exhaust may contain contaminants. 

Can cause severe injury. Pipe exhaust away from work 
area and personnel.
In the event of a diaphragm rupture, material can be 
forced out of the air exhaust muffl

  er.

Pipe the exhaust to a safe remote location when 
pumping hazardous or infl ammable materials.
Use a grounded 1” minimum i.d. hose between the 
pump and the muffl

  er.

WARNING

 HAZARDOUS PRESSURE. Can result in seri-

ous injury or property damage. Do not service or 
clean pump, hoses or dispensing valve while the sys-
tem is pressurized.
Disconnect air supply line and relieve pressure from 
the system by opening dispensing valve or device and 
/ or carefully and slowly loosening and removing out-
let hose or piping from pump.

WARNING

 HAZARDOUS MATERIALS. Can cause serious 

injury or property damage. Do not attempt to return 
a pump to the factory or service center that contains 
hazardous material. Safe handling practices must 
comply with local and national laws and safety code 
requirements.

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

Obtain Material Safety Data Sheets on all materials 
from the supplier for proper handling instructions.

WARNING

 EXPLOSION HAZARD. Models containing alu-

minum wetted parts cannot be used with 1,1,1-trichlo-
roethane, methylene chloride or other halogenated 
hydrocarbon solvents which may react and explode.
Check pump motor section, fl uid caps, manifolds and 
all wetted parts to assure compatibility before using 
with solvents of this type.

WARNING

 MISAPPLICATION HAZARD. Do not use mod-

els containing aluminum wetted parts with food prod-
ucts for human consumption. Plated parts can contain 
trace amounts of lead.

CAUTION

 Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 
flushed or recirculated. Chemical compatibility may 
change with temperature and concentration of the 
chemical(s) within the substances being pumped, 
fl ushed or circulated. For specifi c fl uid compatibility, 
consult the chemical manufacturer.

CAUTION

 Maximum temperatures are based on 

mechanical stress only. Certain chemicals will signifi -
cantly reduce maximum safe operating temperature. 
Consult the chemical manufacturer for chemical com-
patibility and temperature limits. Refer to PUMP DATA 
on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment 

have been trained for safe working practices, under-
stand it’s limitations, and wear safety goggles / equip-
ment when required.

CAUTION

 Do not use the pump for the structural sup-

port of the piping system. Be certain the system com-
ponents are properly supported to prevent stress on 
the pump parts.
Suction and discharge connections should be flex-
ible connections (such as hose), not rigid piped, 
and should be compatible with the substance being 
pumped.

CAUTION

 Prevent unnecessary damage to the pump. 

Do not allow pump to operate when out of material 
for long periods of time.
Disconnect air line from pump when system sits idle 
for long periods of time.

CAUTION

 Use only genuine ARO replacement parts to 

assure compatible pressure rating and longest service 
life.

NOTICE

 Replacement warning labels are available 

upon request: “Static Spark & Diaphragm Rupture” pn 
\ 94080.

WARNING

  = Hazards or unsafe practices which 

could result in severe personal injury, 
death or substantial property damage.

CAUTION

  = Hazards or unsafe practices which 

could result in minor personal injury, 
product or property damage.

NOTICE

  = Important installation, operation or 

maintenance information.

EXCESSIVE AIR PRESSURE
STATIC SPARK

HAZARDOUS MATERIALS
HAZARDOUS PRESSURE

Содержание ARO PP20A A Series

Страница 1: ...imumTemperature Limits diaphragm ball seal materials Nitrile 10 to 180 F 12 to 82 C Santoprene 40 to 225 F 40 to 107 C Dimensional Data see page 12 Mounting Dimension 9 1 16 x10 1 16 230mmx256mm Noise...

Страница 2: ...ERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE Obtain Material Safety Data Sheets on all materials from the supplier for proper handling i...

Страница 3: ...d sections Air operated double diaphragm pumps utilize a pressure dif ferential in the air chambers to alternately create suction and positive fluid pressure in the fluid chambers valve checks insure...

Страница 4: ...are indicated which should be available for fast repair and reduction of down time Service kits are divided to service two separate dia phragm pump functions 1 AIR SECTION 2 FLUID SEC TION The FLUID...

Страница 5: ...PP20A XXX XXX en Page 5 of 12 TYPICAL CROSS SECTION Figure 3...

Страница 6: ...P MATERIAL OPTIONS PP20A XXX XXX Aluminum Stainless Steel N P T BSP N P T BSP Tri Clamp PP20A AAX XXX PP20A BAX XXX PP20A ASX XXX PP20A BSX XXX PP20A CSX XXX Item Description size Qty Part No Mtl Part...

Страница 7: ...screws 65 70 ft lbs 88 1 94 9 Nm Apply Loctite 242 to threads at assembly 26 screws 30 40 ft lbs 40 7 54 2 Nm Apply Loctite 271 to threads at assembly 27 screws 30 40 ft lbs 40 7 54 2 Nm Apply Lubripl...

Страница 8: ...le plug to 135 valve housing securing with 105 screws Install 140 valve insert 141 valve plate 199 gasket and 231 243 and 244 O rings into 135 valve hous ing NOTE Assemble 140 valve insert with dished...

Страница 9: ...35 134 Figure 5 MAJORVALVE PILOTVALVE PART GROUP PARTS LIST PP20A XXX XXX AIR MOTOR SECTION TORQUE REQUIREMENTS NOTE DO NOT OVERTIGHTEN FASTENERS ALL FASTENERS ARE METRIC 105 screw 40 50 in lbs 4 5 5...

Страница 10: ...8 27 P T F 1 94812 258 Button BleedValve 1 8 27 N P T F 1 24130 259 Elbow 5 32 o d tube x 1 8 27 N P T 4 59756 4 260 CheckValve 2 CP10 B 261 Bracket 1 95174 262 Pipe Plug 1 4 18 N P T x 7 16 2 Y17 51...

Страница 11: ...XXX XXX en PARTS LIST PP20A XXX XXX CONTROL SECTION 256 260 256 268 2 long 261 77 277 276 278 275 269 9 long 259 78 14 long 76 See view A A 14 long 78 7 5 long 270 259 266 265 258 257 256 264 263 76 2...

Страница 12: ...XX outlet this side DIMENSIONS A see below E 16 3 32 408 5 mm H 9 1 16 230 2 mm L see below B 24 3 4 628 7 mm F 12 304 8 mm J 10 1 16 255 6 mm M see below C 10 1 16 255 6 mm G 26 1 4 666 8 mm K 9 16 1...

Отзывы: