PM30R-XXX-XXX-CXX (en)

MAINTENANCE

Refer to the part views and descriptions as provided on pag-

es 5 through 8 for parts identification and Service Kit infor-

mation.

 

y

Certain ARO “Smart Parts” are indicated which should be 

available for fast repair and reduction of down time.

 

y

Service kits are divided to service two separate dia-

phragm pump functions: 1. AIR SECTION, 2. FLUID SEC-

TION. The Fluid Section is divided further to match typical 

part Material Options.

 

y

Provide a clean work surface to protect sensitive internal 

moving parts from contamination from dirt and foreign 

matter during service disassembly and reassembly.

 

y

Keep good records of service activity and include the 

pump in preventive maintenance program.

 

y

Before disassembling empty captured material in the 

outlet manifold by turning the pump upside down to 

drain material from the pump.

FLUID SECTION DISASSEMBLY

1.  Remove top manifold(s).

2.  Remove (22) balls, (19) “O” rings (where applicable) and 

(21) seats.

3.  Remove (15) fluid caps.

NOTE:

 Only PTFE diaphragm models use a primary (7) dia-

phragm and a backup (8) diaphragm. Refer to the auxiliary 

view in figure 2.
4.  Remove the (6) diaphragm washer, (7) or (7/8) diaphragm, 

(5) backup washer and (196) cushion.

NOTE:

 Do not scratch or mar the surface of (1) diaphragm 

rod.

FLUID SECTION REASSEMBLY

SERVICE NOTE:

 ARO PN 204214-T Diaphragm assembly tool 

is recommended for use when reassembling the pump.

 

y

Reassemble in reverse order. 

 

y

Clean and inspect all parts. Replace worn or damaged 

parts with new parts as required.

 

y

Lubricate (1) diaphragm rod and (144) “U” cups with Lu-

briplate® FML-2 grease (94276 grease packet is included 

in service kit).

 

y

Be certain the diaphragm assembly bottoms out on the 

(1) rod, back off PTFE diaphragm assembly far enough to 

align holes.

 

y

For models with PTFE diaphragms: Item (8) Santoprene 

diaphragm is installed with the side marked “AIR SIDE” 

towards the pump center body. Install the (7) PTFE dia-

phragm with the side marked “FLUID SIDE” towards the 

fluid cap.

 

y

Re-check torque settings after the pump has been 

re-started and run a while.

GENERAL DESCRIPTION

The ARO diaphragm pump offers high volume delivery even 

at low air pressure and a broad range of material compatibili-

ty options are available. Refer to the model and option chart. 

ARO pumps feature stall resistant design, modular air motor 

/ fluid sections.

Air operated double diaphragm pumps utilize a pressure dif-

ferential in the air chambers to alternately create suction and 

a positive fluid pressure in the fluid chambers, valve checks 

ensure a positive flow of fluid.

Pump cycling will begin as air pressure is applied and will 

continue to pump and keep up with the demand. It will build 

and maintain line pressure and will stop cycling once maxi-

mum line pressure is reached (dispensing device closed) and 

will resume pumping as needed.

AIR AND LUBE REQUIREMENTS

WARNING

 EXCESSIVE AIR PRESSURE. Can cause pump 

damage, personal injury or property damage.

 

y

A filter capable of filtering out particles larger than 50 

microns should be used on the air supply. There is no lu-

brication required other than the “O” ring lubricant which 

is applied during assembly or repair.

 

y

If lubricated air is present, make sure that it is compatible 

with the Nitrile “O” rings in the air motor section of the 

pump.

OPERATING INSTRUCTIONS

 

y

Always flush the pump with a solvent compatible with 

the material being pumped if the material being pumped 

is subject to “setting up” when not in use for a period of 

time.

 

y

Disconnect the air supply from the pump if it is to be in-

active for a few hours.

 

y

The outlet material volume is governed not only by the 

air supply, but also by the material supply available at the 

inlet. The material supply tubing should not be too small 

or restrictive. Be sure not to use hose which might col-

lapse.

 

y

When the diaphr agm pump is used in a forced-feed 

(flooded inlet) situation, it is recommended that a “Check 

Valve” be installed at the air inlet.

 

y

Secure the diaphragm pump legs to a suitable surface to 

ensure against damage by vibration.

y

 Loctite® is registered trademarks of Henkel Loctite Corporation 

y

 ARO® is a registered trademark of Ingersoll-Rand Company 

y

y

 Santoprene® is a registered trademark of ExxonMobil 

y

 271™ and 242® registered trademarks of Henkel Loctite Corporation 

y

y

 Lubriplate® is a registered trademark of Lubriplate Lubricants Company 

y

Содержание ARO PM30R C Series

Страница 1: ...ATA Models see Model Description Chart for XXX Pump Type Metallic Air Operated Double Diaphragm Material see Model Description Chart Weight 253 3 lbs 114 9 kgs Maximum Air Inlet Pressure 120 psig 8 3 bar Maximum Material Inlet Pressure 10 psig 0 69 bar Maximum Outlet Pressure 120 psig 8 3 bar Maximum Flow Rate 237 gpm 897 lpm Flooded inlet 275 gpm 1041 lpm Displacement Cycle 100 psig 2 8 gal 10 6 ...

Страница 2: ...ptions are shown in the chart however certain combinations may not be recommended Consult a representative or the factory if you have questions concerning availability F End of Stroke feedback E End of Stroke feedback Leak Detection L Leak Detection E Solenoid 12 VDC NEC CEC F Solenoid 24 VDC NEC CEC J Solenoid 120 VAC NEC CEC C Sanitary Flange 0 Standard Valve Block No Solenoid S Cycle Sensing on...

Страница 3: ... comply with local and national laws and safety code requirements OPERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE y Obtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions WARNING EXPLOSION HAZARD Models containing aluminum parts cannot be used with 1 1 1 trichlo roethane methylene chlorid...

Страница 4: ...DESCRIPTION The ARO diaphragm pump offers high volume delivery even at low air pressure and a broad range of material compatibili ty options are available Refer to the model and option chart ARO pumps feature stall resistant design modular air motor fluid sections Air operated double diaphragm pumps utilize a pressure dif ferential in the air chambers to alternately create suction and a positive f...

Страница 5: ... 3 16 ID x 2 OD x 5 32 2 97715 SS 14 Cap Screw 3 14 16 x 3 1 4 2 97716 SS 15 Fluid Cap 2 94972 SS 26 Screw M12 x 1 75 6g x 45 mm 12 94412 2 SS 27 Screw M12 x 1 75 6g x 60 mm 16 94991 SS 29 Nut M12 x 1 75 6g 16 95053 SS 60 Inlet Manifold 1 97214 SS 61 Outlet Manifold 1 94969 SS 68 Air Cap 1 94031 1 SS Item Description size Qty Part No Mtl 69 Air Cap 1 94031 2 SS 70 Gasket 2 94100 B 74 Pipe Plug 1 4...

Страница 6: ...Tan SANTOPRENE Green N A Backup PTFE White White SANTOPRENE 7 8 Figure 2 PTFE VIEW OF TWO PIECE PTFE DIAPHRAGM k Apply Lubriplate FML 2 grease to all O rings U Cups and mating parts NOT USED with models PM30R CSS MXX CXX s Apply PTFE tape to threads at assembly x Apply Loctite 242 to threads at assembly g Apply Loctite 271 to threads G Apply anti seize compound to threads 1 8 6 4 2 3 7 5 Torque Se...

Страница 7: ...ACE EACH OTHER 2 Insert 111 spool into 135 valve block 3 Install 137 O ring on 136 end cap and assemble end cap to 135 valve block securing with 107 end plates and 105 screws 4 Install 140 valve insert and 141 valve plate into 135 valve block NOTE Assemble 140 valve insert with dished side toward 141 valve plate Assemble 141 valve plate with 2 identification dots toward 199 and 200 gaskets 5 Assem...

Страница 8: ...LIST PM30R X X CXX AIR SECTION TORQUE REQUIREMENTS NOTE DO NOT OVERTIGHTEN FASTENERS ALL FASTENERS ARE METRIC Torque 105 Screw to 35 40 in lbs 4 0 4 5 Nm Torque 134 Screw to 35 40 in lbs 4 0 4 5 Nm LUBRICATION SEALANTS Apply Lubriplate FML 2 grease to all O rings U cups and mating parts Figure 3 A 637374 Replacement MajorValve Service Assembly is available separately which includes the following 1...

Страница 9: ...st as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non collapsing type capable of pulling a high volume y Check all joints on the inlet manifolds and suction con nections These must be air tight y Inspect the pump for solid objects lodged in the dia phragm chamber or the seat area DIMENSIONAL DATA Dimensions shown a...

Страница 10: ...Page 10 of 12 PM30R XXX XXX CXX en ...

Страница 11: ...PM30R XXX XXX CXX en Page 11 of 12 ...

Страница 12: ...Page 12 of 12 PM30R XXX XXX CXX en PN 97999 1117 ...