Ingersoll-Rand ARO PM30R C Series Скачать руководство пользователя страница 3

PM30R-XXX-XXX-CXX (en) 

Page 3 of 12

WARNING

 EXCESSIVE AIR PRESSURE. Can cause per-

sonal injury, pump damage or property damage.

 

y

Do not exceed the maximum inlet air pressure as stat-

ed on the pump model plate.

 

y

Be sure material hoses and other components are 

able to withstand fluid pressures developed by this 

pump. Check all hoses for damage or wear. Be certain 

dispensing device is clean and in proper working con-

dition.

WARNING

 STATIC SPARK. Can cause explosion re-

sulting in severe injury or death. Ground pump and 

pumping system.

 

y

Use the pump grounding screw terminal provided. 

Use ARO® part no. 66885-1 ground kit or connect a 

suitable ground wire (12 ga. min.) to a good earth 

ground source.

 

y

Secure pump, connections and all contact points to 

avoid vibration and generation of contact or static 

spark.

 

y

Consult local building codes and electrical codes for 

specific grounding requirements.

 

y

After grounding, periodically verify continuity of elec-

trical path to ground. Test with an ohmmeter from 

each component (e.g., hoses, pump, clamps, contain-

er, spray gun, etc.) to ground to ensure continuity. 

Ohmmeter should show 0.1 ohms or less.

 

y

Submerse the outlet hose end, dispensing valve or 

device in the material being dispensed if possible. 

(Avoid free streaming of material being dispensed.)

 

y

Use hoses incorporating a static wire.

 

y

Use proper ventilation.

 

y

Keep inflammables away from heat, open flames and 

sparks.

 

y

Keep containers closed when not in use.

WARNING

 Pump exhaust may contain contaminants. 

Can cause severe injury. Pipe exhaust away from work 

area and personnel.

 

y

In the event of a diaphragm rupture, material can be 

forced out of the air exhaust muffler.

 

y

Pipe the exhaust to a safe remote location when 

pumping hazardous or inflammable materials.

 

y

Use a grounded 1” minimum ID hose between the 

pump and the muffler.

WARNING

 HAZARDOUS PRESSURE. Can result in se-

rious injury or property damage. Do not service or 

clean pump, hoses or dispensing valve while the sys-

tem is pressurized.

 

y

Disconnect air supply line and relieve pressure from 

the system by opening dispensing valve or device and 

/ or carefully and slowly loosening and removing out-

let hose or piping from pump.

WARNING

 HAZARDOUS MATERIALS. Can cause serious 

injury or property damage. Do not attempt to return 

a pump to the factory or service center that contains 

hazardous material. Safe handling practices must 

comply with local and national laws and safety code 

requirements.

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

 

y

Obtain Material Safety Data Sheets on all materials 

from the supplier for proper handling instructions.

WARNING

 EXPLOSION HAZARD. Models containing 

aluminum parts cannot be used with 1,1,1-trichlo-

roethane, methylene chloride or other halogenated 

hydrocarbon solvents which may react and explode.

 

y

Check pump motor section, fluid caps, manifolds and 

all wetted parts to assure compatibility before using 

with solvents of this type.

WARNING

 MISAPPLICATION HAZARD. Do not use 

models containing aluminum wetted parts with food 

products for human consumption. Plated parts can 

contain trace amounts of lead.

CAUTION

 Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 

flushed or recirculated. Chemical compatibility may 

change with temperature and concentration of the 

chemical(s) within the substances being pumped, 

flushed or circulated. For specific fluid compatibility, 

consult the chemical manufacturer.

CAUTION

 Maximum temperatures are based on me-

chanical stress only. Certain chemicals will signifi-

cantly reduce maximum safe operating temperature. 

Consult the chemical manufacturer for chemical com-

patibility and temperature limits. Refer to PUMP DATA 

on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment 

have been trained for safe working practices, under-

stand it’s limitations, and wear safety goggles / equip-

ment when required.

CAUTION

 Do not use the pump for the structural sup-

port of the piping system. Be certain the system com-

ponents are properly supported to prevent stress on 

the pump parts.

 

y

Suction and discharge connections should be flexi-

ble connections (such as hose), not rigid piped, and 

should be compatible with the substance being 

pumped.

CAUTION

 Prevent unnecessary damage to the pump. 

Do not allow pump to operate when out of material 

for long periods of time.

 

y

Disconnect air line from pump when system sits idle 

for long periods of time.

CAUTION

 Use only genuine ARO replacement parts to 

assure compatible pressure rating and longest service 

life.

WARNING

  = Hazards or unsafe practices which 

could result in severe personal injury, 

death or substantial property damage.

CAUTION

  = Hazards or unsafe practices which 

could result in minor personal injury, 

product or property damage.

NOTICE

  = Important installation, operation or 

maintenance information.

EXCESSIVE AIR PRESSURE

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

Содержание ARO PM30R C Series

Страница 1: ...ATA Models see Model Description Chart for XXX Pump Type Metallic Air Operated Double Diaphragm Material see Model Description Chart Weight 253 3 lbs 114 9 kgs Maximum Air Inlet Pressure 120 psig 8 3 bar Maximum Material Inlet Pressure 10 psig 0 69 bar Maximum Outlet Pressure 120 psig 8 3 bar Maximum Flow Rate 237 gpm 897 lpm Flooded inlet 275 gpm 1041 lpm Displacement Cycle 100 psig 2 8 gal 10 6 ...

Страница 2: ...ptions are shown in the chart however certain combinations may not be recommended Consult a representative or the factory if you have questions concerning availability F End of Stroke feedback E End of Stroke feedback Leak Detection L Leak Detection E Solenoid 12 VDC NEC CEC F Solenoid 24 VDC NEC CEC J Solenoid 120 VAC NEC CEC C Sanitary Flange 0 Standard Valve Block No Solenoid S Cycle Sensing on...

Страница 3: ... comply with local and national laws and safety code requirements OPERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE y Obtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions WARNING EXPLOSION HAZARD Models containing aluminum parts cannot be used with 1 1 1 trichlo roethane methylene chlorid...

Страница 4: ...DESCRIPTION The ARO diaphragm pump offers high volume delivery even at low air pressure and a broad range of material compatibili ty options are available Refer to the model and option chart ARO pumps feature stall resistant design modular air motor fluid sections Air operated double diaphragm pumps utilize a pressure dif ferential in the air chambers to alternately create suction and a positive f...

Страница 5: ... 3 16 ID x 2 OD x 5 32 2 97715 SS 14 Cap Screw 3 14 16 x 3 1 4 2 97716 SS 15 Fluid Cap 2 94972 SS 26 Screw M12 x 1 75 6g x 45 mm 12 94412 2 SS 27 Screw M12 x 1 75 6g x 60 mm 16 94991 SS 29 Nut M12 x 1 75 6g 16 95053 SS 60 Inlet Manifold 1 97214 SS 61 Outlet Manifold 1 94969 SS 68 Air Cap 1 94031 1 SS Item Description size Qty Part No Mtl 69 Air Cap 1 94031 2 SS 70 Gasket 2 94100 B 74 Pipe Plug 1 4...

Страница 6: ...Tan SANTOPRENE Green N A Backup PTFE White White SANTOPRENE 7 8 Figure 2 PTFE VIEW OF TWO PIECE PTFE DIAPHRAGM k Apply Lubriplate FML 2 grease to all O rings U Cups and mating parts NOT USED with models PM30R CSS MXX CXX s Apply PTFE tape to threads at assembly x Apply Loctite 242 to threads at assembly g Apply Loctite 271 to threads G Apply anti seize compound to threads 1 8 6 4 2 3 7 5 Torque Se...

Страница 7: ...ACE EACH OTHER 2 Insert 111 spool into 135 valve block 3 Install 137 O ring on 136 end cap and assemble end cap to 135 valve block securing with 107 end plates and 105 screws 4 Install 140 valve insert and 141 valve plate into 135 valve block NOTE Assemble 140 valve insert with dished side toward 141 valve plate Assemble 141 valve plate with 2 identification dots toward 199 and 200 gaskets 5 Assem...

Страница 8: ...LIST PM30R X X CXX AIR SECTION TORQUE REQUIREMENTS NOTE DO NOT OVERTIGHTEN FASTENERS ALL FASTENERS ARE METRIC Torque 105 Screw to 35 40 in lbs 4 0 4 5 Nm Torque 134 Screw to 35 40 in lbs 4 0 4 5 Nm LUBRICATION SEALANTS Apply Lubriplate FML 2 grease to all O rings U cups and mating parts Figure 3 A 637374 Replacement MajorValve Service Assembly is available separately which includes the following 1...

Страница 9: ...st as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non collapsing type capable of pulling a high volume y Check all joints on the inlet manifolds and suction con nections These must be air tight y Inspect the pump for solid objects lodged in the dia phragm chamber or the seat area DIMENSIONAL DATA Dimensions shown a...

Страница 10: ...Page 10 of 12 PM30R XXX XXX CXX en ...

Страница 11: ...PM30R XXX XXX CXX en Page 11 of 12 ...

Страница 12: ...Page 12 of 12 PM30R XXX XXX CXX en PN 97999 1117 ...

Отзывы: