Ingersoll-Rand ARO PF20 B Series Скачать руководство пользователя страница 2

Page 2 of 8 

PF20X-XXX-XXX-B (en)

WARNING

 EXCESSIVE AIR PRESSURE. Can cause per-

sonal injury, pump damage or property damage.

 

y

Do not exceed the maximum inlet air pressure as stat-

ed on the pump model plate.

 

y

Be sure material hoses and other components are able 

to withstand fluid pressures developed by this pump. 

Check all hoses for damage or wear. Be certain dispens-

ing device is clean and in proper working condition.

WARNING

 STATIC SPARK. Can cause explosion re-

sulting in severe injury or death. Ground pump and 

pumping system.

 

y

Use the pump grounding screw terminal provided. 

Use ARO® part no. 66885-1 ground kit or connect a 

suitable ground wire (12 ga. minimum) to a good 

earth ground source.

 

y

Secure pump, connections and all contact points to 

avoid vibration and generation of contact or static 

spark.

 

y

Consult local building codes and electrical codes for 

specific grounding requirements.

 

y

After grounding, periodically verify continuity of elec-

trical path to ground. Test with an ohmmeter from 

each component (e.g., hoses, pump, clamps, contain-

er, spray gun, etc.) to ground, to ensure continuity. 

Ohmmeter should show 0.1 ohms or less.

 

y

Submerse the outlet hose end, dispensing valve or 

device in the material being dispensed if possible. 

(Avoid free streaming of material being dispensed.)

 

y

Use hoses incorporating a static wire.

 

y

Use proper ventilation.

 

y

Keep inflammables away from heat, open flames and 

sparks.

 

y

Keep containers closed when not in use.

WARNING

 Pump exhaust may contain contaminants. 

Can cause severe injury. Pipe exhaust away from work 

area and personnel.

 

y

In the event of a diaphragm rupture, material can be 

forced out of the air exhaust muffler.

 

y

Pipe the exhaust to a safe remote location when 

pumping hazardous or inflammable materials.

 

y

Use a grounded 1” minimum ID hose between the 

pump and the muffler.

WARNING

 HAZARDOUS PRESSURE. Can result in se-

rious injury or property damage. Do not service or 

clean pump, hoses or dispensing valve while the sys-

tem is pressurized.

 

y

Disconnect air supply line and relieve pressure from 

the system by opening dispensing valve or device and 

/ or carefully and slowly loosening and removing out-

let hose or piping from pump.

WARNING

 HAZARDOUS MATERIALS. Can cause serious 

injury or property damage. Do not attempt to return 

a pump to the factory or service center that contains 

hazardous material. Safe handling practices must 

comply with local and national laws and safety code 

requirements.

 

y

Obtain Material Safety Data Sheets on all materials 

from the supplier for proper handling instructions.

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

WARNING

 EXPLOSION HAZARD. Models containing alu-

minum wetted parts cannot be used with 1,1,1-trichlo-

roethane, methylene chloride or other halogenated 

hydrocarbon solvents which may react and explode.

 

y

Check pump motor section, fluid caps, manifolds and 

all wetted parts to assure compatibility before using 

with solvents of this type.

WARNING

 MISAPPLICATION HAZARD. Do not use mod-

els containing aluminum wetted parts with food prod-

ucts for human consumption. Plated parts can contain 

trace amounts of lead.

CAUTION

 Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 

flushed or recirculated. Chemical compatibility may 

change with temperature and concentration of the 

chemical(s) within the substances being pumped, 

flushed or circulated. For specific fluid compatibility, 

consult the chemical manufacturer.

CAUTION

 Maximum temperatures are based on me-

chanical stress only. Certain chemicals will signifi-

cantly reduce maximum safe operating temperature. 

Consult the chemical manufacturer for chemical com-

patibility and temperature limits. Refer to PUMP DATA 

on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment 

have been trained for safe working practices, under-

stand it’s limitations, and wear safety goggles / equip-

ment when required.

CAUTION

 Do not use the pump for the structural sup-

port of the piping system. Be certain the system com-

ponents are properly supported to prevent stress on 

the pump parts.

 

y

Suction and discharge connections should be flexi-

ble connections (such as hose), not rigid piped, and 

should be compatible with the substance being 

pumped.

CAUTION

 Prevent unnecessary damage to the pump. 

Do not allow pump to operate when out of material 

for long periods of time.

 

y

Disconnect air line from pump when system sits idle 

for long periods of time.

CAUTION

 Use only genuine ARO replacement parts to 

assure compatible pressure rating and longest service 

life.

NOTICE

 RE-TORQUE ALL FASTENERS BEFORE OPER-

ATION. Creep of housing and gasket materials may 

cause fasteners to loosen. Torque all fasteners to en-

sure against fluid or air leakage.

WARNING

  = Hazards or unsafe practices which 

could result in severe personal injury, 

death or substantial property damage.

CAUTION

  = Hazards or unsafe practices which 

could result in minor personal injury, 

product or property damage.

NOTICE

  = Important installation, operation or 

maintenance information.

EXCESSIVE AIR PRESSURE

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

Содержание ARO PF20 B Series

Страница 1: ...l Inlet Pressure 10 psig 0 69 bar Maximum Outlet Pressure 120 psig 8 3 bar Maximum Flow Rate 172 gpm 651 lpm Displacement Cycle 100 psig 1 4 gal 5 3 lit Maximum Particle Size 2 dia 51 mm semi solids MaximumTemperature Limits diaphragm flap bumper material E P R EPDM 60 to 280 F 51 to 138 C Hytrel 20 to 180 F 29 to 82 C Nitrile 10 to 180 F 12 to 82 C Polypropylene 32 to 175 F 0 to 79 C Santoprene 4...

Страница 2: ...ta Sheets on all materials from the supplier for proper handling instructions OPERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE WARNING EXPLOSION HAZARD Models containing alu minum wetted parts cannot be used with 1 1 1 trichlo roethane methylene chloride or other halogenated hydrocarbon solvents which may react and explode y Check pump ...

Страница 3: ...fers high volume delivery even at low air pressure and a broad range of material compati bility options available Refer to the model and option chart ARO pumps feature stall resistant design modular air motor fluid sections Air operated double diaphragm pumps utilize a pressure differential in the air chambers to alternately create suction and positive fluid pressure in the fluid chambers flap che...

Страница 4: ...0A X X B 4 94531 A PF20S X X B 4 96656 SS 144 U Cup 3 16 x 1 3 8 OD 1 Y186 51 B 180 Washer 0 406 ID x 0 031 thick 1 94098 Co MATERIAL CODE A Aluminum B Nitrile C Carbon Steel Co Copper CI Cast Iron E E P R H Hytrel L Long Life PTFE SP Santoprene SS Stainless Steel T PTFE U Polyurethane V Viton Smart Parts keep these items on hand in addition to the Service Kits for fast repair and reduction of dow...

Страница 5: ...TION SEALANTS Lubriplate FML 2 is a white food grade petroleum grease Apply Lubriplate FML 2 grease to all O rings U Cups and mating parts Apply Loctite 242 to threads at assembly Apply Loctite 503 pipe sealant Apply anti seize compound to threads when using stainless steel fasteners and stainless steel wet ends 75 75 7 PTFE VIEW OF TWO PIECE PTFE DIAPHRAGM 80 8 6 4 1 7 5 3 2 Torque Sequence 27 74...

Страница 6: ...mble 140 valve insert with dished side to ward 141 valve plate Assemble 141 valve plate with part number identification toward 140 valve insert 5 Assemble 200 and 241 gaskets and 233 adapter plate to 135 valve housing securing with 240 screws 6 Assemble 132 and 166 gaskets and 176 checks to 101 center body 7 Assemble 135 valve housing and components to 101 center body securing with 134 screws AIR ...

Страница 7: ...8 166 132 243 244 199 141 140 240 200 241 128 176 PILOT VALVE PART GROUP MAJOR VALVE A replacement Major Valve Service Assembly is available separately which includes the following 637374 2 for models PF20A XXX SXX B 105 4 111 128 2 132 135 136 137 138 139 140 141 166 176 2 199 200 233 240 2 241 242 243 and 244 637374 4 for models PF20S XXX SXX B 105 4 111 128 2 132 135 136 137 138 139 140 141 146...

Страница 8: ...h vacuum y Check all joints on the inlet manifolds and suction con nections These must be air tight y Inspect the pump for solid objects logged in the dia phragmchamber or the seat area Dimensions shown are for reference only they are displayed in inches and millimeters mm Figure 4 Air Inlet 3 4 14 NPTF 1 Inlet Outlet A C K Dotted lines show optional 67263 muffler assembly B D E F G H J DIMENSIONS...

Отзывы: