TROUBLE SHOOTING

Product discharged from exhaust outlet.

 

y

Check for diaphragm rupture.

 

y

Check tightness of (14) diaphragm screw.

Air bubbles in product discharge.

 

y

Check connections of suction plumbing.

 

y

Check “O” rings between intake manifold and inlet side 

fluid caps.

 

y

Check tightness of (14) diaphragm screw.

Motor blows air or stalls.

 

y

Check (176) check valve for damage or wear.

 

y

Check for restrictions in valve / exhaust.

Low output volume, erratic flow or no flow.

 

y

Check air supply.

 

y

Check for plugged outlet hose.

 

y

Check for kinked (restrictive) outlet material hose.

 

y

Check for kinked (restrictive) or collapsed inlet material 

hose.

 

y

Check for pump cavitation - suction pipe should be sized 

at least as large as the inlet thread diameter of the pump 

for proper flow if high viscosity fluids are being pumped. 

Suction hose must be a non-collapsing type, capable of 

pulling a high volume.

 

y

Check all joints on the inlet manifolds and suction con-

nections. These must be air tight.

 

y

Inspect the pump for solid objects lodged in the dia-

phragm chamber or the seat area.

DIMENSIONAL DATA

Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

Figure 4

DIMENSIONS

“A”

“D”

“J”

“N”

PE30X-XAX-XXX-C0S  23-5/8” (598.7 mm) 

2-3/8” (60.3 mm) 

11” (279.4 mm) 

13-27/32” (351.5 mm)

PE30X-XCX-XXX-C0S  23-5/8” (598.7 mm) 

2-7/16” (61.1 mm)  11-11/16” (296.1 mm)  13-7/8” (352.2 mm)

PE30X-XHX-XXX-C0S  23-1/8” (587.3 mm) 

2-3/4” (69.9 mm) 

11-11/16” (296.1 mm)  14-1/4” (361.4 mm)

PE30X-XSX-XXX-C0S  23-1/8” (587.3 mm) 

2-3/4” (69.9 mm) 

11-11/16” (296.1 mm)  14-1/4” (361.4 mm)

Dotted lines show 

optional 67263 

muffler assembly.

A -  see below

B -  30” (761.7 mm)

C -  12-1/16” (306.5 mm)

D -  see below

E -  17-11/16” (449.2 mm)

F -  15” (381.0 mm)

G -  32” (812.5 mm)

H -  10-5/32” (258.0 mm)

J -  see below

K -  9/16” (14.3 mm)

L -  2-3/4” (69.9 mm)

M -  23-3/32” (586.3 mm)

N -  see below

P -  1-23/32” (43.4 mm)

Q -  33/64” (13.2 mm)

R -  1-1/32” (26.3 mm)

Содержание ARO PE30 C0S Series

Страница 1: ...DM 60 to 280 F 51 to 138 C Hytrel 20 to 180 F 29 to 82 C Nitrile 10 to 180 F 12 to 82 C Kynar PVDF 10 to 200 F 12 to 93 C Santoprene 40 to 225 F 40 to 107 C PTFE 40 to 225 F 4 to 107 C Viton 40 to 350...

Страница 2: ...ith local and national laws and safety code requirements READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE y y Obtain Material Safety Data Sheets on all materials from the...

Страница 3: ...grease 94276 grease packet is included in service kit y y Be certain the diaphragm assembly bottoms out on the 1 rod back off PTFE diaphragm assembly far enough to align holes y y For models with PTF...

Страница 4: ...ll XX Diaphragm 7 8 3 Diaphragm Qty Mtl Diaphragm Qty Mtl O Ring 1 8 x 1 o d Qty Mtl XXA 637303 XXA 637303 XA 94091 A 2 Sp Y328 210 2 T XXB 637303 XXB 637303 XB 94110 A 2 Sp Y328 210 2 T XXC 637303 XX...

Страница 5: ...octite 271 to threads Apply Loctite 572 to threads Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when using stainless steel fasteners Not used with PE30X X...

Страница 6: ...d lubricate parts not being replaced from service kit 2 Replace 173 O rings and assemble 121 plugs 3 Assemble 132 and 166 gaskets and 176 checks to 101 center body 4 Assemble 160 air manifold to 101 c...

Страница 7: ...6 Nm LUBRICATION SEALANTS Apply Lubriplate FML 2 grease to all O rings U cups and mating parts Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when us ing st...

Страница 8: ...at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non collapsing type capable of pulling a high volume y y Che...

Отзывы: