background image

PE30X-XXX-XXX-C0S (en) 

Page 7 of 8

PARTS LIST / PE30X-XXX-XXX-C0S AIR SECTION

 ASSEMBLY TORQUE REQUIREMENTS 

NOTE: DO NOT OVERTIGHTEN FASTENERS.

ALL FASTENERS ARE METRIC.

(134) Screw, 40 - 50 in. lbs (4.5 - 5.6 Nm).

LUBRICATION / SEALANTS

  Apply Lubriplate FML-2 grease to all “O” rings, “U” cups 

and mating parts.

  Apply anti-seize compound to threads and bolt and 

nut flange heads which contact pump case when us-

ing stainless steel fasteners.

Figure 3

 

 134

 132

 176

133

43

160

173 

121

 

 166

173 

121

103

101

127

201

Optional 94117 Muffler

 

147 

146 

Substitute these “O” rings

 for “166” gasket on 

models PE30S-XXX-XXX-C0S.

Содержание ARO PE30 C0S Series

Страница 1: ...DM 60 to 280 F 51 to 138 C Hytrel 20 to 180 F 29 to 82 C Nitrile 10 to 180 F 12 to 82 C Kynar PVDF 10 to 200 F 12 to 93 C Santoprene 40 to 225 F 40 to 107 C PTFE 40 to 225 F 4 to 107 C Viton 40 to 350...

Страница 2: ...ith local and national laws and safety code requirements READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE y y Obtain Material Safety Data Sheets on all materials from the...

Страница 3: ...grease 94276 grease packet is included in service kit y y Be certain the diaphragm assembly bottoms out on the 1 rod back off PTFE diaphragm assembly far enough to align holes y y For models with PTF...

Страница 4: ...ll XX Diaphragm 7 8 3 Diaphragm Qty Mtl Diaphragm Qty Mtl O Ring 1 8 x 1 o d Qty Mtl XXA 637303 XXA 637303 XA 94091 A 2 Sp Y328 210 2 T XXB 637303 XXB 637303 XB 94110 A 2 Sp Y328 210 2 T XXC 637303 XX...

Страница 5: ...octite 271 to threads Apply Loctite 572 to threads Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when using stainless steel fasteners Not used with PE30X X...

Страница 6: ...d lubricate parts not being replaced from service kit 2 Replace 173 O rings and assemble 121 plugs 3 Assemble 132 and 166 gaskets and 176 checks to 101 center body 4 Assemble 160 air manifold to 101 c...

Страница 7: ...6 Nm LUBRICATION SEALANTS Apply Lubriplate FML 2 grease to all O rings U cups and mating parts Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when us ing st...

Страница 8: ...at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non collapsing type capable of pulling a high volume y y Che...

Отзывы: