background image

Page 8 of 8 

666300-XXX-C (en)

PN 97999-1157

A

E

G

M

L

F

N

B

H

J

D

K

C

P

S - 

Exhaust port

Q - 

Material inlet

Q - 

Material outlet

R - 

Air inlet

TROUBLE SHOOTING

Product discharged from exhaust outlet.

y

Check for diaphragm rupture.

y

Check tightness of (14) diaphragm screw.

Air bubbles in product discharge.

y

Check connections of suction plumbing.

y

Check “O” rings between intake manifold and fluid caps.

y

Check tightness of (14) diaphragm screw.

Low output volume, erratic flow or no flow.

y

Check air supply.

y

Check for plugged outlet hose.

y

Check for kinked (restrictive) outlet material hose.

y

Check for kinked (restrictive) or collapsed inlet material hose.

y

Check for pump cavitation - suction pipe should be sized at

least as large as the inlet thread diameter of the pump for

proper flow if high viscosity fluids are being pumped. Suction

hose must be a non-collapsing type, capable of pulling a high

volume.

y

Check all joints on the inlet manifolds and suction connections. 

These must be air tight.

y

Inspect the pump for solid objects lodged in the diaphragm

chamber or the seat area.

DIMENSIONAL DATA

Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

Figure 5

DIMENSIONS

A - 22-7/32” 

(563.9 mm)

B - 30” 

(762.0 mm)

C - 12-1/16” 

(306.4 mm)

D - 2-3/8” 

(60.3 mm)

E  - 24-7/16” 

(620.7 mm)

F - 16” 

(406.4 mm)

G  -  see below

H - 10-5/32” 

(258.0 mm)

J - 11” 

(279.4 mm)

K - 9/16” 

(14.3 mm)

L  -  see below

M - 11-1/8” 

(281.9 mm)

N - 11-3/32” 

(281.4 mm)

Model

“Q”

666300-XXX-C  3 - 8 NPTF - 2

666320-XXX-C  Rp 3 (3 - 11 BSP, parallel)

P - 5-1/4” 

(133.4 mm)

Q  -  see below

R  -  3/4 - 14 NPTF - 2

S  -  1-1/4 - 11-1/2 NPTF - 2

Model “G”

“L”

6663X0-XXX-C 32-9/32” 

(819.8 mm)

 2-3/4” 

(69.9 mm)

6663X1-XXX-C 32-3/16” 

(816.8 mm)

 2-5/8” 

(66.7 mm)

6663X2-XXX-C 32-9/32” 

(819.8 mm)

 2-3/4” 

(69.9 mm)

6663XA-XXX-C 32-9/32” 

(819.8 mm)

 2-3/4” 

(69.9 mm)

6663XB-XXX-C 32-3/16” 

(816.8 mm)

 2-5/8” 

(66.7 mm)

6663XC-XXX-C 32-9/32” 

(819.8 mm)

 2-3/4” 

(69.9 mm)

Содержание ARO 666300 C Series

Страница 1: ...erature Limits diaphragm ball seal seat material E P R EPDM 60 to 280 F 51 to 138 C Hytrel 20 to 180 F 29 to 82 C Kynar PVDF 10 to 200 F 12 to 93 C Nitrile 10 to 180 F 12 to 82 C Santoprene 40 to 225...

Страница 2: ...ND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE jury or property damage Do not attempt to return a pump to the factory or service center that contai...

Страница 3: ...uts to avoid twisting the diaphragms y For models with PTFE diaphragms Item 8 Santoprene dia phragm is installed with the side marked AIR SIDE towards the pump center body Install the PTFE diaphragm w...

Страница 4: ...Diaphragm XX Ball XX Diaphragm Diaphragm Qty Mtl Diaphragm Qty Mtl O Ring Qty Mtl O Ring Qty Mtl XX2 637433 XX2 637433 X2 97291 2 2 B Y325 210 2 B Y325 350 4 B XX4 637433 XX4 637433 X4 96476 T 2 T 96...

Страница 5: ...and nut flange heads which contact pump case when using stain less steel fasteners Not used with models 6663XX 9XX C 6663XX EXX C and 6663XX GXX C PARTS LIST 6663XX XXX C FLUID SECTION FORTHE AIR MO T...

Страница 6: ...onto 115 spacer and insert etc NOTE Be careful to orient spacer legs away from blocking internal ports 2 Lubricate and carefully insert 111 spool 3 Install 117 gasket and 107 plate 4 Lubricate and ins...

Страница 7: ...IGHTEN FASTENERS 105 screw 40 50 in lbs 4 5 5 6 Nm 123 screw 20 25 in lbs 2 3 2 8 Nm LUBRICATION SEALANTS Apply Key Lube grease to all O rings U cups and mating parts Apply Loctite 271 to threads Appl...

Страница 8: ...pumped Suction hose must be a non collapsing type capable of pulling a high volume y Check all joints on the inlet manifolds and suction connections These must be air tight y Inspect the pump for soli...