WARNING

 EXCESSIVE AIR PRESSURE. Can cause personal 

injury, pump damage or property damage.

y

Do not exceed the maximum inlet air pressure as stated on
the pump model plate.

y

Be sure material hoses and other components are able to
withstand fluid pressures developed by this pump. Check

all hoses for damage or wear. Be certain dispensing device

is clean and in proper working condition.

WARNING

 STATIC SPARK. Can cause explosion resulting in

severe injury or death. Ground pump and pumping system.

y

Sparks can ignite flammable material and vapors.

y

The pumping system and object being sprayed must be
grounded when it is pumping, flushing, recirculating or spray-

ing flammable materials such as paints, solvents, lacquers,

etc. or used in a location where surrounding atmosphere is

conducive to spontaneous combustion. Ground the dispens-

ing valve or device, containers, hoses and any object to which 

material is being pumped.

y

Use the pump grounding screw terminal provided. Use ARO® 
part no. 66885-1 ground kit or connect a suitable ground wire 

(12 ga. minimum) to a good earth ground source.

y

Secure pump, connections and all contact points to avoid
vibration and generation of contact or static spark.

y

Consult local building codes and electrical codes for spe-
cific grounding requirements.

y

After grounding, periodically verify continuity of electrical
path to ground. Test with an ohmmeter from each compo-

nent (e.g., hoses, pump, clamps, container, spray gun, etc.)

to ground to insure continuity. Ohmmeter should show 0.1

ohms or less.

y

Submerse the outlet hose end, dispensing valve or device
in the material being dispensed if possible. (Avoid free

streaming of material being dispensed.)

y

Use hoses incorporating a static wire.

y

Use proper ventilation.

y

Keep inflammables away from heat, open flames and
sparks.

y

Keep containers closed when not in use.

WARNING

 Pump exhaust may contain contaminants. Can 

cause severe injury. Pipe exhaust away from work area and 

personnel.

y

In the event of a diaphragm rupture, material can be forced 
out of the air exhaust muffler.

y

Pipe the exhaust to a safe remote location when pumping
hazardous or inflammable materials.

y

Use a grounded 3/4” minimum ID hose between the pump
and the muffler.

WARNING

 HAZARDOUS PRESSURE. Can result in serious 

injury or property damage. Do not service or clean pump, 

hoses or dispensing valve while the system is pressurized.

y

Disconnect air supply line and relieve pressure from the
system by opening dispensing valve or device and / or

carefully and slowly loosening and removing outlet hose or 

piping from pump.

WARNING

 HAZARDOUS MATERIALS. Can cause serious in-

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

jury or property damage. Do not attempt to return a pump 

to the factory or service center that contains hazardous 

material. Safe handling practices must comply with local 

and national laws and safety code requirements.

y

Obtain Material Safety Data Sheets on all materials from
the supplier for proper handling instructions.

WARNING

 EXPLOSION HAZARD. Models containing alu-

minum parts cannot be used with 1,1,1-trichloroethane, 

methylene chloride or other halogenated hydrocarbon 

solvents which may react and explode.

y

Check pump motor section, fluid caps, manifolds and all
wetted parts to assure compatibility before using with sol-

vents of this type.

WARNING

 MISAPPLICATION HAZARD. Do not use models

containing aluminum wetted parts with food products

for human consumption. Plated parts can contain trace

amounts of lead.

CAUTION

 Verify the chemical compatibility of the pump

wetted parts and the substance being pumped, flushed or

recirculated. Chemical compatibility may change with tem-

perature and concentration of the chemical(s) within the

substances being pumped, flushed or circulated. For spe-

cific fluid compatibility, consult the chemical manufacturer.

CAUTION

 Maximum temperatures are based on mechanical 

stress only. Certain chemicals will significantly reduce max-

imum safe operating temperature. Consult the chemical

manufacturer for chemical compatibility and temperature

limits. Refer to PUMP DATA on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment have

been trained for safe working practices, understand it’s

limitations, and wear safety goggles / equipment when re-

quired.

CAUTION

 Do not use the pump for the structural support of 

the piping system. Be certain the system components are 

properly supported to prevent stress on the pump parts.

y

Suction and discharge connections should be flexible con-
nections (such as hose), not rigid piped, and should be

compatible with the substance being pumped.

CAUTION

 Prevent unnecessary damage to the pump. Do

not allow pump to operate when out of material for long

periods of time.

y

Disconnect air line from pump when system sits idle for
long periods of time.

CAUTION

 Use only genuine ARO replacement parts to as-

sure compatible pressure rating and longest service life.

NOTICE

 Replacement warning labels are available upon

request: “Static Spark (93616-1) & Diaphragm Rupture”

(93122).

WARNING

= Hazards or unsafe practices which 

could result in severe personal injury, 

death or substantial property damage.

CAUTION

  = Hazards or unsafe practices which 

could result in minor personal injury, 

product or property damage.

NOTICE

= Important installation, operation or 

maintenance information.

EXCESSIVE AIR PRESSURE

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

Содержание ARO 666300 C Series

Страница 1: ...erature Limits diaphragm ball seal seat material E P R EPDM 60 to 280 F 51 to 138 C Hytrel 20 to 180 F 29 to 82 C Kynar PVDF 10 to 200 F 12 to 93 C Nitrile 10 to 180 F 12 to 82 C Santoprene 40 to 225...

Страница 2: ...ND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE jury or property damage Do not attempt to return a pump to the factory or service center that contai...

Страница 3: ...uts to avoid twisting the diaphragms y For models with PTFE diaphragms Item 8 Santoprene dia phragm is installed with the side marked AIR SIDE towards the pump center body Install the PTFE diaphragm w...

Страница 4: ...Diaphragm XX Ball XX Diaphragm Diaphragm Qty Mtl Diaphragm Qty Mtl O Ring Qty Mtl O Ring Qty Mtl XX2 637433 XX2 637433 X2 97291 2 2 B Y325 210 2 B Y325 350 4 B XX4 637433 XX4 637433 X4 96476 T 2 T 96...

Страница 5: ...and nut flange heads which contact pump case when using stain less steel fasteners Not used with models 6663XX 9XX C 6663XX EXX C and 6663XX GXX C PARTS LIST 6663XX XXX C FLUID SECTION FORTHE AIR MO T...

Страница 6: ...onto 115 spacer and insert etc NOTE Be careful to orient spacer legs away from blocking internal ports 2 Lubricate and carefully insert 111 spool 3 Install 117 gasket and 107 plate 4 Lubricate and ins...

Страница 7: ...IGHTEN FASTENERS 105 screw 40 50 in lbs 4 5 5 6 Nm 123 screw 20 25 in lbs 2 3 2 8 Nm LUBRICATION SEALANTS Apply Key Lube grease to all O rings U cups and mating parts Apply Loctite 271 to threads Appl...

Страница 8: ...pumped Suction hose must be a non collapsing type capable of pulling a high volume y Check all joints on the inlet manifolds and suction connections These must be air tight y Inspect the pump for soli...