background image

Page  3 of 8

66620XĆXĆC

GENERAL DESCRIPTION

The ARO Diaphragm Pump offers high volume delivery even at low air
pressure and a broad range of material compatibility options available.
Refer to the model and option chart. ARO pumps feature stall resistant
design, modular air motor / fluid sections.
Air operated double diaphragm pumps utilize a pressure differential in
the air chambers to alternately create suction and positive fluid pressure
in the fluid chambers, valve checks insure a positive flow of fluid.
Pump cycling will begin as air pressure is applied and it will continue to
pump and keep up with the demand. It will build and maintain line presĆ
sure and will stop cycling once maximum line pressure is reached (disĆ
pensing device closed) and will resume pumping as needed.

AIR AND LUBE REQUIREMENTS

WARNING

EXCESSIVE AIR PRESSURE. Can cause pump

damage, personal injury or property damage.

S

A filter capable of filtering out particles larger than 50 microns should
be used on the air supply. There is no lubrication required other than
the O" ring lubricant which is applied during assembly or repair.

S

If lubricated air is present, make sure that is compatible with the NiĆ
trile O" rings in the air motor section of the pump.

OPERATING INSTRUCTIONS

S

Always flush the pump with a solvent compatible with the material
being pumped if the material being pumped is subject to setting up"
when not in use for a period of time.

S

Disconnect the air supply from the pump if it is to be inactive for a few
hours.

S

The outlet material volume is governed not only by the air supply, but
also by the material supply available at the inlet. The material supply
tubing should not be too small or restrictive. Be sure not to use hose
which might collapse.

S

When the diaphragm pump is used in a forcedĆfeed (flooded inlet)
situation, it is recommended that a Check Valve" be installed at the
air inlet.

S

Secure the diaphragm pump legs to a suitable surface to insure
against damage by vibration.

MAINTENANCE

Refer to the part views and descriptions as provided on pages 4 through
7 for parts identification and service kit information.

S

Certain ARO Smart Parts" are indicated which should be available
for fast repair and reduction of down time.

S

Service kits are divided to service two separate diaphragm pump
functions: 1. AIR SECTION, 2. FLUID SECTION. The FLUID SECĆ
TION is divided further to match typical part MATERIAL OPTIONS.

S

Provide a clean work surface to protect sensitive internal moving
parts from contamination from dirt and foreign matter during service
disassembly and reassembly.

S

Keep good records of service activity and include pump in prevenĆ
tive maintenance program.

S

Before disassembling, empty captured material in the outlet manĆ
ifold by turning the pump upside down to drain material from the
pump.

FLUID SECTION DISASSEMBLY

1. Remove top manifold(s).
2. Remove (22) balls, (19) O" rings and (21) seats.
3. Remove (15) fluid caps.
NOTE:
a backup diaphragm (8). Refer to the auxiliary view in the Fluid Section
illustration.
4. Remove the (6) nut, (7) or (7 / 8) diaphragms and (5) washers.
5. Remove (3) O" rings.
NOTE: Do not scratch or mar the surface of (1) diaphragm rod.

FLUID SECTION REASSEMBLY

S

Reassemble in reverse order.

S

Clean and inspect all parts. Replace worn or damaged parts with
new parts as required.

S

Lubricate (1) diaphragm rod and (2) O" ring with KeyĆLube

R

 

O" ring

lube.

S

Use ARO PN / 98931ĆT Bullet (installation tool) to aid in installation
of (2) O" ring on (1) diaphragm rod.

S

Be certain (7) or (7 / 8) diaphragm(s) align properly with (15) fluid
caps before making final torque adjustments on bolt and nuts to
avoid twisting the diaphragm.

S

is installed with the side marked AIR SIDE" towards the pump cenĆ

SIDE" towards the fluid cap.

S

ReĆcheck torque settings after pump has been reĆstarted and run a
while.

S

 

Viton

R

 and Hytrel

R

 are trademarks of the DuPont Company

 

Kynar

R

 is a trademark of Penwalt Corp

Santoprene

R

 is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P.

 

KeyĆLube

R

 is a registered trademark of Key Industries.

PTFE

PTFE

PTFE

Содержание ARO 66620 C Series

Страница 1: ...rethane 10_ to 150_ F 12_ to 66_ C P V D F KynarR 10_ to 200_ F 12_ to 93_ C SantopreneR 40_ to 225_ F 40_ to 107_ C 0_ to 225_ F 4_ to 107_ C VitonR 40_ to 350_ F 40_ to 177_ C Dimensional Data see p...

Страница 2: ...e while the system is pressurized S Disconnect air supply line and relieve pressure from the sys tem by opening dispensing valve or device and or carefully and slowly loosening and removing outlet hos...

Страница 3: ...uitable surface to insure against damage by vibration MAINTENANCE Refer to the part views and descriptions as provided on pages 4 through 7 for parts identification and service kit information S Certa...

Страница 4: ...4 o d Qty Mtl XX1 637124 X1 92755 1 2 N Y325 16 4 B Y325 230 4 B XX2 637124 X2 2 B Y325 16 4 B Y325 230 4 B XX3 637124 X3 92755 3 2 V Y328 16 4 T Y327 230 4 V XX4 637124 X4 94617 94616 2 T SP Y328 16...

Страница 5: ...ENE Green Green S NITRILE Black Red S SANTOPRENE Tan Tan SANTOPRENE Green N A Backup White White URETHANE N A Red VITON Yellow Yellow S Stripe S Dot See item 8 in inset below 21 19 k 22 26 16 59 15 22...

Страница 6: ...AL REASSEMBLY NOTES S Air Motor Section Service is continued from Fluid Section repair S Inspect and replace old parts with new parts as necessary Look for deep scratches on metallic surfaces and nick...

Страница 7: ...S SECTION DETAIL 109 110 k 112 114 k 113 k 115 111 116 Figure 3 107 127 126Z LUBRICATION SEALANTS IMPORTANT BE CERTAIN TO ORIENT 115 SPACER LEGS AWAY FROM BLOCKING INTERNAL PORTS WHEN REASSEMBLING AIR...

Страница 8: ...the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non col lapsing type capable of pulling a high vacuum S Check all joints on the i...

Отзывы: