1. The first digit of the scale factor will be flashing.

2. Press the “TOTAL” button to scroll thru the numbers.

Scale Factor Screen

Figure 12

3. Press the “RESET” button to advance to the next number in the

scale factor.

4. Repeat steps 2 and 3 for all five digits in the scale factor. NOTE: All

digits can be scrolled between 0 and 9, except the first, which can

only be scrolled from 0 to 1.

5. When finished setting the scale factor, press the “RESET” button

and the scale factor and units measurement screen will be replaced

with the pulse delay screen.

Setting the Pulse Delay Factor

The pulse delay factor is used to correct for fast flow rates by closing the

valve in the meter between one and five pulses sooner than the selected

value. The meter is factory programmed with a pulse delay factor of 0.

Pulse Delay Screen

Figure 13

Advance thru the unit selection and all five scale factor digits by pressing

the “RESET” button. The above screen (see figure 13) will now be dis-

played.

1. The “PS-” will be followed by a flashing zero. The zero is the initial

setting of the pulse delay factor.

2. Scroll between settings (0 - 5) by pressing the “TOTAL” button.

3. When finished selecting the pulse delay factor, press the “RESET”

button and the display will return to the scale factor screen.

4. When finished programming these options, press the “PROGRAM-

MING” key and hold it until the screen flashes three times then goes

blank. Press the “RESET” button to return to the normal operating

screen.

TROUBLE SHOOTING

WARNING

Relieve the pressure prior to checking or repair-

ing the meter. Make sure all valves, controls and pumps are op-

erating correctly.

Battery icon is displayed.

S

Batteries are low.

a. Replace batteries.

Display is blank.

S

Meter is asleep.

a. Push “RESET” button.

S

Batteries are dead.

a. Replace batteries, push “RESET” button.

S

Program error.

a. Remove and reinsert batteries, push “RESET” button.

S

Loose battery connection.

a. Removebatteriesandcheckbatteryconnection, push“RESET”

button.

Meter does not latch for batching.

S

Meter is not in “AUTO” mode.

a. Press “AUTO” button and program batch size.

S

Meter was not reset after prior batch.

a. Press “RESET” button.

S

Low batteries.

a. Check for battery icon, replace batteries, push “RESET” button.

Slow or no fluid flow.

S

Filter is clogged.

a. Clean or replace the filter in the swivel nut.

S

Pump pressure is low.

a. Turn up the pump pressure.

S

Foreign material is jamming meter.

a. Contact your local distributor for repair.

Meter is inaccurate.

S

The scale factor is not correct for the fluid.

a. Enter program mode, check and reset program factor.

Batch overruns program value.

S

The pulse delay value is set too low.

a. Enter program mode, reset pulse delay to a higher value.

Содержание ARO 635360-2

Страница 1: ...r Mechanism Oval gears Flow Rate Range 1 4 8 g p m 1 30 l p m Operating Temperature Range 20_ to 120_ F 5_ to 50_ C Accuracy Oils 0 5 Anti freeze 1 5 LCD Display Batch Total 3 digits 99 9 units Cumula...

Страница 2: ...ch meter is programmed in quarts for use with motor oil The meter is shipped in the manual mode If you need to change the factory settings see page 4 The meter display panel has seven push buttons see...

Страница 3: ...he dis play from flashing Also in case of an emergency or to interrupt a batch the meter is equipped with a mechanical override see Mechanical Override CAUTION The valve will always lock in the maximu...

Страница 4: ...tton toadvance Theunitsofmeasurementiconwillstopflashingandthe first digit of the scale factor will begin flashing NOTE Ifthe L unitshavebeenselected thedecimalpointwillbeginto flash Theusernowhastheo...

Страница 5: ...return to the scale factor screen 4 When finished programming these options press the PROGRAM MING key and hold it untilthe screenflashes threetimes thengoes blank Press the RESET button to return to...

Страница 6: ...635360 X en Page 6 of 8 DIMENSIONAL DATA 11 065 281 1 mm 9 650 245 1 mm 3 500 88 9 mm 6 684 169 8 mm 1 2 14 N P T 1 2 14 N P T...

Страница 7: ...5360 X en NON DRIP NOZZLE ASSEMBLIES 629245 1 Flexible Automatic Low Flow 629245 2 Rigid Automatic Low Flow 629516 Flexible Hose 11 1 2 292 1 mm approximately 7 177 8 mm approximately 13 5 8 346 1 mm...

Страница 8: ...635360 X en Page 8 of 8 PN 97999 1124...

Отзывы: