![Ingersoll-Rand ARO 635360-2 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/ingersoll-rand/aro-635360-2/aro-635360-2_operators-manual_2059985002.webp)
635360-X (en)
Page 2 of 8
OPERATING AND SAFETY PRECAUTIONS
READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.
WARNING
EQUIPMENT MISUSE HAZARD.
S
This equipment is for professional use only.
S
Read all instructions, tags and labels before operating this
equipment.
S
Use this equipment only for its intended purpose.
S
Do not modify or alter this equipment.
S
Do not leave equipment unattended while dispensing.
S
Check equipment daily. Repair or replace worn or damaged
parts immediately.
S
Do not exceed the maximum working pressure level of the low-
est rated system component.
S
Use only extensions and nozzles that are designed for use with
this equipment.
S
Use only fluids and solvents that are compatible with this
equipment. Read all fluid and solvent manufacturer’s warn-
ings.
S
Tighten all fluid connections before operating this equipment.
S
Do not stop or deflect leaks with hands, body, gloves or rags.
S
Do not dispense valves toward any person or any part of the
body.
S
Do not place hands or fingers over the end of or into the dis-
pense valve.
S
Comply with all local, state and federal fire, electrical and safe-
ty regulations.
S
Use of this product in a manner other than specified in this
manual may result in impaired operation or damage to equip-
ment.
WARNING
CAUTION
NOTICE
= Hazards or unsafe practices which could
result in severe personal injury, death or
substantial property damage.
= Hazards or unsafe practices which could
result in minor personal injury, product
or property damage.
= Important installation, operation or
maintenance information.
GENERAL INFORMATION
The electronic digital flow meter is designed to provide precise metering
of motor oils (S.A.E. 5 - 50), gear oils (S.A.E. 80 - 240), automatic trans-
mission fluid, antifreeze solution and hydraulic fluid. The meter is not de-
signed to dispense brake fluid or windshield wiper fluid.
This meter uses oval gears, which respond to flow, and rotate dividing
the fluid into single volumes (units). As the gears rotate, they generate a
signal,viaamagneticcoupling,whichprotectsthemicro-processorfrom
exposure to the fluid. The micro-processor uses a calibration “factor”
and calculates pulses generated by the gear rotations into calibrated
flow units which display in either quarts or liters on the meter register
(batch total).
Each meter is preprogrammed and calibrated at the factory. Unless
otherwise specified at the time of the order, each meter is programmed
in quarts for use with motor oil. The meter is shipped in the “manual”
mode. If you need to change the factory settings, see page 4.
The meter display panel has seven push-buttons (see figure 2):
Keypad Buttons “10”, “1”, “0.1” -
Used to enter the quantity to be dis-
pensed.
“Total” -
Used to display the accumulated total of fluid, as well as the
resettable total during “auto” and “manual” modes.
“Auto” -
Used to enter and exit the “auto” mode.
“Reset” -
Used in “manual” or “auto” modes to clear the previously pro-
grammed batch and to reset the meter. Used to reset the resettable
total after pressing the “TOTAL” button.
“Shut-Off” -
Used to stop the flow thru a mechanical override.
Figure 2
INSTALLATION
Pre-Installation Procedure
1. Relieve the system pressure:
a. Turn off the power supply to the pump or close the shutoff valve.
b. Dispense any fluid in the system into a waste container by open-
ing the dispense valve.
c. Open all bleed-type master air valves and fluid drain valves in
the system.
d. Leave the drain valve open until ready to pressurize the system.
2. Close the shutoff valve.
3. Ground hoses and reels. Grounding reduces the risk of static spark-
ing. Ground all system components according to local, state and
federalcodes. Consult the user’smanual of the pump and other sys-
tem components to ground the following:
a. Pump - Follow the manufacturer’s recommendations.
b. Air and fluid hoses - Use only grounded hoses.
c. Air compressor - Follow the manufacturer’s recommendations.
d. Fluid supply container - Follow the local code.
WARNING
Do not use Teflon
R
tape on pipe joints. It may
cause a loss of grounding across the joint.
Installation Procedure
1. If this is an existing installation, go directly to step 6. Steps 2 thru 5
are for flushing the system prior to installing the meter.
2. Close the fluid dispense valves at every dispense position.
3. Once the main fluid outlet valve at the pump is closed, the air pres-
suretothepumpmotorisproperlyadjustedandthe airvalve isopen,
slowly open the main fluid valve.
4. Place the hose end in a waste container. Make sure the hose is se-
cure so no fluid will leak during flushing.
5. Slowly open the dispense valve and allow enough oil to pass thru to
ensure that the system is clean. Close the valve and repeat for all
dispense positions. NOTE: If the system hasmultiple dispense posi-
tions, begin at the position farthest from the pump and move toward
the pump.
6. Relieve the pressure (see “Relieve the system pressure:”, above).
7. Insert the metal end of the hose into the swivel located at the end of
the handle and tighten completely using an open ended, adjustable
wrench (see figure 3).
Teflon