background image

Page 2 of 8 

66M2X0-XXX-C (en)

WARNING

 EXCESSIVE AIR PRESSURE. Can cause personal 

injury, pump damage or property damage.
Do not exceed the maximum inlet air pressure as stated on 
the pump model plate.
Be sure material hoses and other components are able to 
withstand fl uid pressures developed by this pump. Check 
all hoses for damage or wear. Be certain dispensing device 
is clean and in proper working condition.

WARNING

 STATIC SPARK. Can cause explosion resulting in 

severe injury or death. Ground pump and pumping system.
Sparks can ignite fl ammable material and vapors.
The pumping system and object being sprayed must be 
grounded when it is pumping, fl ushing, recirculating or spray-
ing flammable materials such as paints, solvents, lacquers, 
etc. or used in a location where surrounding atmosphere is 
conducive to spontaneous combustion. Ground the dispens-
ing valve or device, containers, hoses and any object to which 
material is being pumped.
Use the pump grounding screw terminal provided. Use ARO® 
part no. 66885-1 ground kit or connect a suitable ground wire 
(12 ga. minimum) to a good earth ground source.
Secure pump, connections and all contact points to avoid 
vibration and generation of contact or static spark.
Consult local building codes and electrical codes for spe-
cifi c grounding requirements.
After grounding, periodically verify continuity of electrical 
path to ground. Test with an ohmmeter from each compo-
nent (e.g., hoses, pump, clamps, container, spray gun, etc.) 
to ground to insure continuity. Ohmmeter should show 0.1 
ohms or less.
Submerse the outlet hose end, dispensing valve or device 
in the material being dispensed if possible. (Avoid free 
streaming of material being dispensed.)
Use hoses incorporating a static wire.
Use proper ventilation.
Keep inflammables away from heat, open flames and 
sparks.
Keep containers closed when not in use.

WARNING

 Pump exhaust may contain contaminants. Can 

cause severe injury. Pipe exhaust away from work area and 
personnel.
In the event of a diaphragm rupture, material can be forced 
out of the air exhaust muffl

  er.

Pipe the exhaust to a safe remote location when pumping 
hazardous or infl ammable materials.
Use a grounded 3/4” minimum i.d. hose between the pump 
and the muffl

  er.

WARNING

 HAZARDOUS PRESSURE. Can result in serious 

injury or property damage. Do not service or clean pump, 
hoses or dispensing valve while the system is pressurized.
Disconnect air supply line and relieve pressure from the 
system by opening dispensing valve or device and / or 
carefully and slowly loosening and removing outlet hose or 
piping from pump.

WARNING

 HAZARDOUS MATERIALS. Can cause serious in-

y

y

y

y

y

y

y

y

y

y

y

y

y

y

y

y

y

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

jury or property damage. Do not attempt to return a pump 
to the factory or service center that contains hazardous 
material. Safe handling practices must comply with local 
and national laws and safety code requirements.
Obtain Material Safety Data Sheets on all materials from 
the supplier for proper handling instructions.

WARNING

 EXPLOSION HAZARD. Models containing alu-

minum parts cannot be used with 1,1,1-trichloroethane, 
methylene chloride or other halogenated hydrocarbon 
solvents which may react and explode.
Check pump motor section, fluid caps, manifolds and all 
wetted parts to assure compatibility before using with sol-
vents of this type.

WARNING

 MISAPPLICATION HAZARD. Do not use models 

containing aluminum wetted parts with food products 
for human consumption. Plated parts can contain trace 
amounts of lead.

CAUTION

 Verify the chemical compatibility of the pump 

wetted parts and the substance being pumped, fl ushed or 
recirculated. Chemical compatibility may change with tem-
perature and concentration of the chemical(s) within the 
substances being pumped, flushed or circulated. For spe-
cifi c fl uid compatibility, consult the chemical manufacturer.

CAUTION

 Maximum temperatures are based on mechanical 

stress only. Certain chemicals will signifi cantly reduce max-
imum safe operating temperature. Consult the chemical 
manufacturer for chemical compatibility and temperature 
limits. Refer to PUMP DATA on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment have 

been trained for safe working practices, understand it’s 
limitations, and wear safety goggles / equipment when re-
quired.

CAUTION

 Do not use the pump for the structural support of 

the piping system. Be certain the system components are 
properly supported to prevent stress on the pump parts.
Suction and discharge connections should be fl exible con-
nections (such as hose), not rigid piped, and should be 
compatible with the substance being pumped.

CAUTION

 Prevent unnecessary damage to the pump. Do 

not allow pump to operate when out of material for long 
periods of time.
Disconnect air line from pump when system sits idle for 
long periods of time.

CAUTION

 Use only genuine ARO replacement parts to as-

sure compatible pressure rating and longest service life.

NOTICE

 Replacement warning labels are available upon 

request: “Static Spark (93616-1) & Diaphragm Rupture” 
(93122).

WARNING

  = Hazards or unsafe practices which 

could result in severe personal injury, 
death or substantial property damage.

CAUTION

  = Hazards or unsafe practices which 

could result in minor personal injury, 
product or property damage.

NOTICE

  = Important installation, operation or 

maintenance information.

y

y

y

y

EXCESSIVE AIR PRESSURE
STATIC SPARK

HAZARDOUS MATERIALS
HAZARDOUS PRESSURE

Содержание 66M2X0-XXX-C

Страница 1: ...ia 19 1 mm MaximumTemperature Limits diaphragm ball seal material E P R EPDM 60 to 280 F 51 to 138 C Hytrel 20 to 150 F 29 to 66 C Nitrile 10 to 180 F 12 to 82 C Santoprene 40 to 225 F 40 to 107 C Vit...

Страница 2: ...ND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE jury or property damage Do not attempt to return a pump to the factory or service center that contai...

Страница 3: ...diaphragms Re check torque settings after the pump has been re started and run a while y y y y y 1 2 3 y y y y y y GENERAL DESCRIPTION The ARO diaphragm pump offers high volume delivery even at low ai...

Страница 4: ...X2 96391 G 2 B Y325 237 4 B XX9 637468 X9 96391 C 2 H Y327 237 4 V XXB 637468 XB 96391 A 2 Sp 94356 4 E COMMON PARTS Item Description size Qty Part No Mtl o 1 Rod 1 97071 C n 2 O Ring 3 32 x 1 o d 1 Y...

Страница 5: ...t lbs 88 1 94 9 Nm 26 screw 30 40 ft lbs 40 7 54 2 Nm 27 screw 30 40 ft lbs 40 7 54 2 Nm LUBRICATION SEALANTS c Apply Key Lube grease to all O rings U cups and mating parts d Apply Loctite 271 to thre...

Страница 6: ...113 O ring onto 115 spacer and insert etc NOTE Be careful to orient spacer legs away from blocking internal ports Lubricate and carefully insert 111 spool Install 117 gasket and 107 plate Lubricate a...

Страница 7: ...FASTENERS 105 screw 40 50 in lbs 4 5 5 6 Nm 123 screw 20 25 in lbs 2 3 2 8 Nm LUBRICATION SEALANTS c Apply Key Lube grease to all O rings U cups and mating parts d Apply Loctite 271 to threads f Appl...

Страница 8: ...tation suction pipe should be sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non collapsing type capa...