background image

Page 2 of 8 

6661HX-XXX-C (en)

WARNING

 EXCESSIVE GAS PRESSURE. Can cause per-

sonal injury, pump damage or property damage.
Do not exceed the maximum inlet gas pressure as 
stated on the pump model plate.
Be sure material hoses and other components are able 
to withstand fl uid pressures developed by this pump. 
Check all hoses for damage or wear. Be certain dispens-
ing device is clean and in proper working condition.

WARNING

 STATIC SPARK. Can cause explosion result-

ing in severe injury or death. Ground pump and 
pumping system.
Use the pump ground lug provided. Connect to a 12 
ga. (minimum) wire (kit is included) to a good earth 
ground source.
Sparks can ignite fl ammable material and vapors.
The pump must be electrically grounded using the 
grounding conductor provided. Improper grounding 
can cause improper and dangerous operation.
Secure pump, connections and all contact points to 
avoid vibration and generation of contact or static 
spark.
Consult local building codes and electrical codes for 
specifi c grounding requirements.
After grounding, periodically verify continuity of 
electrical path to ground. Test with an ohmmeter 
from each component (e.g., hoses, pump, clamps, con-
tainer, spray gun, etc.) to ground to insure continuity. 
Ohmmeter should show 0.1 ohms or less.
Submerse the outlet hose end, dispensing valve or 
device in the material being dispensed if possible. 
(Avoid free streaming of material being dispensed.)
Use hoses incorporating a static wire.
Use proper ventilation.
Keep infl ammables away from heat, open fl ames and 
sparks.
Keep containers closed when not in use.

WARNING

 Pump exhaust may contain contaminants. 

Can cause severe injury. Pipe exhaust away from work 
area and personnel.
The gas outlet of the pump must be vented to a safe lo-
cation in accordance with local codes or, in the absence 
of local codes, an industry or nationally recognized 
code having jurisdiction over the specifi c installation.
Use a grounded 3/8” minimum i.d. hose between the 
pump and the muffl

  er.

WARNING

 HAZARDOUS PRESSURE. Can result in seri-

ous injury or property damage. Do not service or 
clean pump, hoses or dispensing valve while the sys-
tem is pressurized.
Disconnect gas supply line and relieve pressure from 
the system by opening dispensing valve or device and 
/ or carefully and slowly loosening and removing out-
let hose or piping from pump.

WARNING

 HAZARDOUS MATERIALS. Can cause serious 

injury or property damage. Do not attempt to return 
a pump to the factory or service center that contains 
hazardous material. Safe handling practices must 
comply with local and national laws and safety code 

y

y

y

y

y

y

y

y

y

y

y

y

y

y

y

y

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

requirements.
Obtain Material Safety Data Sheets on all materials 
from the supplier for proper handling instructions.

WARNING

 EXPLOSION HAZARD. Models containing alu-

minum wetted parts cannot be used with 1,1,1-trichlo-
roethane, methylene chloride or other halogenated 
hydrocarbon solvents which may react and explode.
Check pump motor section, fl uid caps, manifolds and 
all wetted parts to assure compatibility before using 
with solvents of this type.

CAUTION

 Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 
flushed or recirculated. Chemical compatibility may 
change with temperature and concentration of the 
chemical(s) within the substances being pumped, 
fl ushed or circulated. For specifi c fl uid compatibility, 
consult the chemical manufacturer.

CAUTION

 Maximum temperatures are based on 

mechanical stress only. Certain chemicals will signifi -
cantly reduce maximum safe operating temperature. 
Consult the chemical manufacturer for chemical com-
patibility and temperature limits. Refer to PUMP DATA 
on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment 

have been trained for safe working practices, under-
stand it’s limitations, and wear safety goggles / equip-
ment when required.

CAUTION

 Do not use the pump for the structural sup-

port of the piping system. Be certain the system com-
ponents are properly supported to prevent stress on 
the pump parts.
Suction and discharge connections should be flex-
ible connections (such as hose), not rigid piped, 
and should be compatible with the substance being 
pumped.

CAUTION

 Prevent unnecessary damage to the pump. 

Do not allow pump to operate when out of material 
for long periods of time.
Disconnect gas line from pump when system sits idle 
for long periods of time.

CAUTION

 Use only genuine ARO® replacement parts 

to assure compatible pressure rating and longest ser-
vice life.

NOTICE

 Install the pump in the vertical position. 

The pump may not prime properly if the balls do not 
check by gravity upon start-up.

NOTICE

 Re-torque all fasteners before operation. 

Creep of housing and gasket materials may cause 
fasteners to loosen. Re-torque all fasteners to insure 
against fl uid or gas leakage.

NOTICE

 Replacement warning labels are available 

upon request: “Static Spark” pn \ 93616-1, Diaphragm 
Rupture” pn \ 93122.

WARNING

  = Hazards or unsafe practices which 

could result in severe personal injury, 
death or substantial property damage.

CAUTION

  = Hazards or unsafe practices which 

could result in minor personal injury, 
product or property damage.

NOTICE

  = Important installation, operation or 

maintenance information.

y

y

y

y

EXCESSIVE GAS PRESSURE
STATIC SPARK

HAZARDOUS MATERIALS
HAZARDOUS PRESSURE

Содержание 6661HX-XXX-C

Страница 1: ...bs 8 62 kgs Maximum Gas Inlet Pressure 120 p s i g 8 3 bar Maximum Material Inlet Pressure 10 p s i g 0 69 bar Maximum Outlet Pressure 120 p s i g 8 3 bar Maximum Flow Rate flooded inlet 35 g p m 133...

Страница 2: ...y y y y y OPERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE requirements Obtain Material Safety Data Sheets on all materials from the suppl...

Страница 3: ...ARO natural gas powered diaphragm pump offers high volume delivery even at low gas pressure Natural gas pow ered diaphragm pumps move fluids such as crude oil salt water drilling mud lubrication oils...

Страница 4: ...ARTS LIST Item Description size Qty Part No Mtl Item Description size Qty Part No Mtl 1 Rod 1 98724 1 C 2 O Ring 3 32 x 3 4 o d 1 Y330 113 B 3 O Ring 1 16 x 5 8 o d 4 Y328 14 T 5 Washer Air side 3 5 8...

Страница 5: ...TION SEALANTS Apply Loctite 271 to threads Apply Key Lube grease 93706 1 to all O rings U cups and mating parts NOTICE Radius edge of parts 5 and 6 is against diaphragm PARTS LIST 6661HX XXX C FLUID S...

Страница 6: ...for scratches and gouges Reach into the gas section exhaust side and remove 116 spacer 115 spacers 113 O rings 114 O rings 112 washers etc Check for damaged O rings MAJOR VALVE REASSEMBLY Replace 112...

Страница 7: ...62 to threads Apply Loctite 572 to threads Apply Loctite 577 to threads Figure 4 MAJORVALVE CROSS SECTION DETAIL 122 118 123 121 103 102 104 197 124 105 107 133 198 107 105 121 43 104 123 101 197 128...

Страница 8: ...east as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non collapsing type capable of pulling a high vacuum Check all j...