Warranty For Trane C-Series Ductless Systems and Related Accessories

Warranty For Trane C-Series Ductless Systems and 
Related Accessories

Products Covered

This warranty is extended by Trane, and applies to all Trane C-Series Ductless Systems and 
Accessories for these products which are sold by Trane and applied in accordance with Trane 
specifications.

Basic Warranty

The warrantor warrants for a period of 5 years from the initial start-up or 5 years and 6 months from 
date of shipment, whichever is less, against failure due to defects in material and manufacture and 
that it has the capacities and ratings set forth in Company's catalogs and bulletins ("Warranty").

If any part of your C-Series Ductless System fails because of a manufacturing defect under normal 
use and maintenance within the Limited Warranty Period, the Company will furnish the required 
replacement part. If the compressor, outdoor coil or indoor coil should be the part that fails during 
the Limited Warranty Period, the affected unit will be replaced. The purchaser must pay for any and 
all shipping and handling charges and other costs of warranty service for the replacement part 
including, but not limited to, any related service labor, diagnosis calls and refrigerant.

Exclusions and Limitations

Exclusions from this Warranty include damage or failure arising from: wear and tear; corrosion, 
erosion, deterioration; modifications made by others to the Equipment; repairs or alterations by 
a party other than Company that adversely affects the stability or reliability of the Equipment; 
vandalism; neglect; accident; adverse weather or environmental conditions; abuse or improper 
use; improper installation; commissioning by a party other than Company; unusual physical or 
electrical or mechanical stress; operation with any accessory, equipment or part not specifically 
approved by Company; refrigerant not supplied by Company; and/or lack of proper maintenance 
as recommended by Company. Company shall not be obligated to pay for the cost of lost 
refrigerant or lost product. Company's obligations and liabilities under this Warranty are limited to 
furnishing replacement equipment or parts, at its option, FCA (Incoterms 2000) factory or 
warehouse (f.o.b. factory or warehouse for US domestic purposes) at Company-designated 
shipping point, freight-allowed to Company's warranty agent's stock location, for all non-
conforming Company-manufactured Equipment (which have been returned by Customer to 
Company. Returns must have prior written approval by Company and are subject to restocking 
charge where applicable. Equipment, material and/or parts that are not manufactured by Company 
are not warranted by Company and have such warranties as may be extended by the respective 
manufacturer. 

COMPANY MAKES NO REPRESENTATION OR WARRANTY, EXPRESS OR IMPLIED, 

REGARDING PREVENTION OF MOLD/MOULD, FUNGUS, BACTERIA, MICROBIAL GROWTH, OR 
ANY OTHER CONTAMINATES.

 No warranty liability whatsoever shall attach to Company until 

Customer’s complete order has been paid for in full and Company's liability under this Warranty 
shall be limited to the purchase price of the Equipment shown to be defective. EXCEPT FOR 
COMPANY’S WARRANTY EXPRESSLY SET FORTH HEREIN, COMPANY DOES NOT MAKE, AND 
HEREBY EXPRESSLY DISCLAIMS, ANY WARRANTIES, EXPRESS OR IMPLIED CONCERNING ITS 
PRODUCTS, EQUIPMENT OR SERVICES, INCLUDING, WITHOUT LIMITATION, ANY WARRANTY 
OF DESIGN, MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE, OR OTHERS 
THAT ARE ALLEGED TO ARISE FROM COURSE OF DEALING OR TRADE.

Additional warranty protection is available on an extra-cost basis and must be in writing and 
agreed to by an authorized signatory of the Company. Additional terms and conditions of warranty 
coverage are applicable for refrigeration equipment. If you wish further help or information 
concerning this warranty, contact: Trane—Warrantor, 2701 Wilma Rudolph Blvd., Clarksville, TN. 37040.

Содержание 4MUC4518A10N0A

Страница 1: ...installed adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags sticker...

Страница 2: ...nd to make changes to its content without obligation to notify any person of such revision or change Trademarks All trademarks referenced in this document are the trademarks of their respective owners...

Страница 3: ...Insulation 16 Refrigerant Pipes 16 Drainage Hose 16 Wiring the Unit 17 Power Wiring 17 Communications Wiring 17 Electrical Conduit Installation 19 Configuration 20 Using the Technician Utilities Tool...

Страница 4: ...11 Reserved for future use Digit 12 Region of sale Digit 13 Reserved for future use Digit 14 Minor design sequence 4 M U C 4 5 1 8 A 1 0 N 0 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 4 R 410A M Mini split in...

Страница 5: ...ed Sufficient clearance must be maintained around the unit Condensate must be managed correctly and safety away from the unit The unit should be installed in a way that prevents unauthorized access Th...

Страница 6: ...4 57 370 13 6 346 7 28 185 13 330 9 5 240 10 6 270 11 8 300 Sub duct connection Unit inch mm Dimension Weight Diameter Model 4MUC4518A10N0A 4MUC4524A10N0A 4MUC4530A10N0A 4MUC4536A10N0A 4MUC4542A10N0A...

Страница 7: ...ng for Installation Service Clearances Clearance Model 4MUC4518A10N0A 4MUC4524A10N0A 4MUC4530A10N0A 4MUC4536A10N0A 4MUC4542A10N0A 4MUC4548A10N0A C 10 253 13 3 337 Obstruction 59 1500 minimum 0 79 20 0...

Страница 8: ...ocations 4 Screw two nuts to each suspension bolt leaving space between the nuts for hanging the unit Note If the suspension bolts are longer than 59 in 1 5 m or vibrations are a concern place isolato...

Страница 9: ...the unit unscrew the pinch pipes from the ends of both gas and liquid refrigerant pipes Make sure all gas has escaped before connecting the piping Note To prevent dirt or foreign objects from getting...

Страница 10: ...tallation manual All refrigerant connections must be accessible for servicing and maintenance Pipe Cutting Required tools Pipe cutter Reamer Pipe holder 1 Using a pipe cutter cut the pipe so that the...

Страница 11: ...pipes and tighten the flare nuts manually and then with a spanner torque wrench applying the torque according to pipe dimensions R 410A clutch type Conventional flare tool Clutch type Wing nut type 0...

Страница 12: ...efrigerant or other hazardous toxic or flammable gas may be leaking Refrigerant or other gases could displace available oxygen to breathe causing possible asphyxiation or other serious health risks So...

Страница 13: ...er depending on the unit type 2 Wrap the insulation supplied around the drain hose and clamp the connection as tightly as possible until you can see at least 8 holes 3 Install the drain pipe into the...

Страница 14: ...s necessary to set the drain hose at a sufficient slope installing a vertical drain pipe within 11 8 in 300 mm from the drain hose port see A If raised higher than 21 65 in 550 mm water leaks may resu...

Страница 15: ...below Testing the Drainage After completing the installation test the drainage to make sure there are no leaks 1 Operate the unit in cool mode 2 Remove drain pump cover 3 Squirt water into the drain p...

Страница 16: ...surface of the drain pipe that is inside the building including the connection between the drain hose and drain stub Clamp tightly Pipe Pipe size in mm Insulation Type Standard conditions 86 F 30 C 8...

Страница 17: ...nit s Use an appropriate screwdriver for tightening the terminal screws A screwdriver with a small head will strip the head and make proper tightening impossible Over tightening the terminal screws ma...

Страница 18: ...2 Wiring terminals Indoor unit Power cable Outdoor unit Communication cable Grounding Disconnect Circuit breaker 1 L 2 N N L L1 L2 L1 L2 L1 L2 Indoor unit Main power cable Cable clamp Outdoor unit Ind...

Страница 19: ...39A EN 19 Wiring the Unit Electrical Conduit Installation A conduit bracket must be installed to secure the conduit as illustrated in Figure 3 p 19 Figure 3 Conduit bracket installation 1 2 3 Push 4 5...

Страница 20: ...procedure 1 At the Indoor Unit Option Writer screen on the TUT select the desired option codes by referring to Table 1 p 23 2 Use the following table and notes to determine which digits can be modifie...

Страница 21: ...ion mode Auto Cool Dry and ON OFF icons as shown below See The 2 Digit Segments for more detailed information 3 To change the value of the left digit on the display press the Fan down button To change...

Страница 22: ...ed in Figure 5 to set the wireless remote to Installation Option 1 Figure 5 Two digit segments in the 24 digit sequence Notes 1 Digits 1 7 13 and 19 shown in green are factory set and cannot be change...

Страница 23: ...ailable Factory set to 0 4 Enable only when a remote temperature sensor is used 0 Disabled 1 Enabled 5 Central control 0 Disabled 1 Enabled 6 RPM up 0 Disabled 1 Enabled N A 7 Factory set to 1 Cannot...

Страница 24: ...available Factory set to 0 a Cassette type indoor units are set to Enabled 3 minute delay regardless of digit 8 setting b For heat pump systems the master indoor unit controls whether the system oper...

Страница 25: ...heating source in combination with the unit Defrost When the unit runs in Heat mode frost may form due to the temperature difference between the unit and the outside air If this happens The unit stops...

Страница 26: ...l fan will be off to prevent a cold air dump when the heat pump is in defrost mode Anti short cycle timer The compressor observes a 3 minute off time when cycling power to the unit or after an outage...

Страница 27: ...mounted to the grill to prevent it from dropping 2 Detach the grill by first removing the safety clip and then removing the hinge Pull the green switch on the hinge part down and then press and pull...

Страница 28: ...ged as a result of opening the grill cycle power to the unit to restore the blades to their proper angle Periodic Maintenance Checks Refer to the schedule given in Table 2 for proper unit maintenance...

Страница 29: ...hat the unit has not been installed in direct sunlight If so hang curtains or shades on windows to filter the sun and increase unit efficiency The fan speed does not change Verify that Auto or Dry mod...

Страница 30: ...code Explanation Remarks 416 Compressor down due to protection control of the discharge temperaturesensor Outdoor unit protection control 450 Error due to condenser temperature sensor when in cooling...

Страница 31: ...approved by Company refrigerant not supplied by Company and or lack of proper maintenance as recommended by Company Company shall not be obligated to pay for the cost of lost refrigerant or lost produ...

Страница 32: ...portfolio of advanced controls and HVAC systems comprehensive building services and parts For more information visit www IRCO com The manufacturer has a policy of continuous product and product data...

Отзывы: