55
2.3 Adjusting the no-load maximum or minimum speed
1) After warming the engine up, gradually raise
the speed and set it at the no-load maximum
revolution.
2) If the no-load maximum revolution is out of the
standard, adjust it by turning the high idle limiting
bolt.
3) Then set the no-load minimum speed by
adjusting the low idle limiting bolt.
Standards (Unit: min
-1
)
Engine application class
Rating speed
No-load maximum
No-load minimum
1500
1575 1625
CL
1800
1870 1920
1200 or more
2000
2180 2230
2200
2395 2445
2400
2590 2640
2500
2700 2750
2600
2785 2835
2800
2970 3020
VM
3000
3185 3235
800 or more
Note) The engine speed may differ from the above standard depending on an engine installed on a machine