background image

 

iWL2xx Wireless Series  

  

 22/31 

 

Copyright © 2011 Ingenico

 

900003061 R11 000 04/1050

 

 

 

All rights reserved 

SAM1/SAM2/SIM readers compartment 

 

The trapdoor for  battery, SAM1/SAM2/SIM, readers located underneath the terminal, 
must be in place during the normal operation of the terminal. See sections "Removal 
of SAM1/SAM2/SIM, modules" as well as "Connecting the battery".  

On airplanes 

 

Your  handset  must  be  switched  off  by  removing  the  battery  pack.  Remove  the 
battery from the terminal when on an airplane.

 

 

Non-compliance  with  these  safety  rules  may  result  in  legal  action  and/or  a  ban  on 
later access to cellular network services. 

Explosion areas

 

 

Some regulations restrict the use  of radio equipment in chemical plants, fuel depots 
and  any  site  where  blasting  is  carried  out.  You  are  urged  to  comply  with  these 
regulations.  The  terminal  shall  be  protected  by  a  specially  fitted  and  certified  cover 
enabling use in proximity to a fuel pump. 

Electronic health appliances 

 

Your handset is a radio transmitter which may interfere with health appliances, such 
as hearing aids, pacemaker, hospital equipment, etc. 

Your  doctor  or  the  equipment  manufacturer  will  be  able  to  provide  you  with 
appropriate advice. 

6.2.

 

Security of your terminal  

Upon receipt of your terminal you should check for signs of tampering of the equipment. It 
is  strongly  advised  that  these  checks  are  performed  regularly  after  receipt.  You  should 
check, for example: that the keypad is firmly in place; that there is no evidence of unusual 
wires that have been connected to any ports on your terminal or associated equipment, the 
chip card reader, or any other part of your terminal. Such checks would provide warning of 
any  unauthorised  modifications  to  your  terminal,  and  other  suspicious  behaviour  of 
individuals that have access to your terminal. Your terminal detects any “tampered state”. 
In  this  state  the  terminal  will  repeatedly  flash  the  message”  Alert  Irruption!”  and  further 
use of the terminal will not be possible. If you observe the “Alert Irruption!” message, you 
should contact the terminal helpdesk immediately.  
You are strongly advised to ensure that privileged access to your terminal is only granted to 
staff that have been independently verified as being trustworthy.  

 

CAUTION  

NEVER ask the customer to divulge their PIN Code. Customers should be advised to ensure 
that they are not being overlooked when entering their PIN Code. 
The terminal must never be put in or left at a location where it could be stolen or replaced 
with another device. 

6.3.

 

Telephone call 

You have an urgent call to make while the iWL2XX  is occupying the line. 
In order to get a dial tone in short time: 
Place the handset in the hang up position 

pressing the red key (=cancel)  

or 

disconnet the base power supply from the mains network 

or 

disconnet  the  iWL2XX  telephone  connector  from  the  telephone  call  socket,  and 

place the telephone connector into the telephone wall socket. 

 

You hear a dial tone within 6 seconds. 

Содержание iWL2 Series

Страница 1: ...INGENICO 192 avenue Charles de Gaulle 92200 Neuilly sur Seine FRANCE T l 33 0 1 46 25 82 00 Fax 33 0 1 47 72 56 95 www ingenico com iWL2xx Wireless Series U s e r G u i d e...

Страница 2: ...________________ 10 4 1 Recommendations ___________________________________________________ 10 4 2 Terminal connections _________________________________________________ 10 4 3 Installing Modules_____...

Страница 3: ...ations____________________________________________ 21 6 1 Safety______________________________________________________________ 21 6 2 Security of your terminal ________________________________________...

Страница 4: ...uide to understand and make the best use of your terminal It presents you the necessary information about use installation maintenance safety and security recommendations WARRANTY SECURITY Use only th...

Страница 5: ...power supply with apparently similar voltage current characteristics may damage your terminal This product can be powered by an IT network only in Norway In Switzerland plug must complying with SEV 10...

Страница 6: ...Weight without paper roll nor battery 290g for the R25 model and 310g for the R40 model Dimensions L x w x h 150x76x44mmfor the R25 model and 164 5x76x53 5mm for the R40 model Mains network 100 240VAC...

Страница 7: ...s displayed on black and white display press simultaneously and navigator UP key in order to increase the contrast or and navigator DOWN key in order to decrease the contrast Keep pressing the keys as...

Страница 8: ...reen key on the keyboard 3 3 Reading cards Magnetic stripe card The card can be read either from bottom to top or from topto bottom with the stripe facing the terminal Use a regular movement in order...

Страница 9: ...ling the terminal on the base Connecting the terminal on the base Place the iWL2XX between the flanges on its base so that the contacts of the iWL2XX engage on the contacts provided on the base see pi...

Страница 10: ...his her body to conceal the PIN when it is requested Operating conditions Ambiant temperature from 10 C to 40 C Max relative humidity 85 at 40 C Charging conditions Ambiant temperature from 0 C to 40...

Страница 11: ...picture Close the trapdoor TIP Use a piece of adhesive tape to grip the SAM for easier and faster removal 4 3 2 MicroSD Memory Card CAUTION Switch off the terminal before opening the trapdoor MicroSD...

Страница 12: ...SD Memory Card Turn the terminal and unclip the trapdoor by pushing on the clips with your nails as shown with the arrows on the picture Remove battery pack disconnecting is not necessary Remove the M...

Страница 13: ...rage in hot wet places near air conditioner humidity higher than 85 exposure to sunlight or ultraviolet for long periods contact with organic solvents solvent type adhesive direct contact with materia...

Страница 14: ...roll in the compartment following the directions shown on the below picture Pull the paper up to the top of the terminal Maintain the paper and close the cover Press simultaneously on both upper corne...

Страница 15: ...off the terminal prior to connecting the battery Turn your terminal and unclip the battery trapdoor by pushing on the clips with your nails as shown on the picture Disengage the trapdoor Take the batt...

Страница 16: ...charge takes place influences battery lifetime and autonomy number of transactions The optimal conditions are as follows Charging away from any external heat source radiator sun enclosed area The opti...

Страница 17: ...g the instructions below a Unlock the connector by pressing the locking mechanism as indicated by F1 arrow while pulling wires F2 arrow to disconnect the connector Release traction on it as soon as th...

Страница 18: ...ns WARNING Select an electrical socket that complies with the general safety instruction given in section 6 Recommendations of this document Follow the below instructions Connect the power supply unit...

Страница 19: ...Follow the below instructions to connect the base to the telephone network Disconnect power supply unit socket B in order to switch off the base prior to connecting it to the appropriate network Conn...

Страница 20: ...possible to fasten base on desk thanks to buttonholes located on base bottom casing Uses pattern beside to best locate screws position WARNING Base must be set in horizontal position to insure termina...

Страница 21: ...battery Do not attempt to remove the battery housing as its components cannot be modified Do not disassemble Batteries in end oflife must be disposed of at the appropriates sites The lifespan depends...

Страница 22: ...y after receipt You should check for example that the keypad is firmly in place that there is no evidence of unusual wires that have been connected to any ports on your terminal or associated equipmen...

Страница 23: ...C EMC Directive EN 55024 A2 2003 According to 2004 108 EC EMC Directive EN 301489 1 7 08 2005 According to 89 336 EEC EMC Directive EN 301 511 12 2003 According to 1999 5 EC R TTE Directive EN 62311 2...

Страница 24: ...anada licence exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received includ...

Страница 25: ...armful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or te...

Страница 26: ...et son gain de sorte que la puissance isotrope rayonn e quivalente p i r e ne d passe pas l intensit n cessaire l tablissement d une communication satisfaisante This device complies with Industry Can...

Страница 27: ...out the requirement not to dispose of WEEE as unsorted municipal waste and to collect such WEEE separately To assure that the product is collected and recycled with respect to the environment you must...

Страница 28: ...Check that the tone of the phone line is free Check the configuration of the phone line and number to call Get technical support Cards are not read Check if the magnetic card is swiped correctly with...

Страница 29: ...ply unit USB 192010876 AUS traveler power supply unit USB 192010579 CE base power supply unit Jack 192010582 UK base power supply unit Jack 192010602 US base power supply unit Jack 192010623 CHN base...

Страница 30: ...900003061 R11 000 04 1050 All rights reserved 296109815 USB Cord microB on terminal side USBA male on the other side 1 5 m black 296109807 USB Cord microB on terminal side USBA female on the other sid...

Страница 31: ...ient ensures that any other recipient of this document or information contained therein is held responsible to INGENICO for the confidentiality of that information Care has been taken to ensure that t...

Отзывы: