7/18/2014
Specialized Business Solutions
Page 3
Ingenico i6550 PIN Pad & Signature Capture
Accessing the Extended Menu
1) Restart the terminal by pressing 1 + Cancel (red) + Enter (green).
2) Immediately press 1 and 3 simultaneously and hold until the Extended Menu Appears.
2a) On newer units, just press and hold the Cancel (red) until the Extended Menu Appears.
3) Using the - key, highlight Supervisor Menu and press Enter (green).
4) Enter the Password: 2634
5) Using the - key, highlight SysParameters and press Enter (green).
6) Select Auto Detect, AD On/Off, and verify it is set to USB/RS232.
7) Using the Cancel (red) button twice, return to the Sys Parameters
8) Using the + key, highlight SetupPort and hit Enter (green).
9) Using the - key, select HostPort and set it to COM1.
10) Verify PORT1, PORT2, and PORT3 and compare to the below settings:
- Port1 Settings:
Interface Type: Auto Detect
Baud Rate:
19200
Databits:
8
Stopbits:
1
Parity:
N
- Port2 Settings:
Interface Type: RS232
Baud Rate:
19200
Databits:
8
Stopbits:
1
Parity:
N
- Port3 Settings: Same as Port 1 Settings.
11) Using the Cancel (red) button, return to Setup Port
12) Verify AuxPort is set to COM2
13) Verify SCVPort is set to COM3
14) Lastly, hit Cancel (red) enough times until the unit restarts.