Technical date table 

 

General dimensions (mm) 

Models 

Long Wide  High 

Maximum

Power 

 (Kw) 

Phases

Maximum 

Engineering 

(A)

 

Main 

Supply 

(V)

 

Weight 

(Kg) 

PE-60NS 600  438  223-233 

II 

16,6 

240 

32 

PE-80NS 800  438  223-233  5,3 

II 

22 

240 

46 

PE-60NC 600  438  223-233 

II 

16,6 

240 

47 

PE-80NC 800  438  223-233  5,3 

II 

22 

240 

66 

 
The register number of the plate is on the back part (see the draw of electric connexion) 
keeping all the necessary details to do the electrical engineering. 
 

Placing 

To place the machine does attention it will be well level, correcting any unevenness with the 
adjustable feet (to screwing or unscrewing). The general electrical engineering switch will be 
placed near to the machine and wit easy access. 
 We advise to install the machine under the extractor Hood with the finality to absorb quickly 
the vapour. 
In the case the machine will be placed near the walls, party wall, cooking furniture, ornamental 
coating, etc. We advise that it will be in inflammable material. It must be sure that the fire-
fighting regulations will be respected. 
 

Guidelines 

The installation must be done with the following guidelines: 
· Anti-incident Prescription in force. 
· Installation prescription, CEI rules. 
 

Installation 

The installation, start and maintenance of the machine will be made by authorised personnel.  
All related with the installation will respect the guidelines in force. 
The manufacturer will not be held responsible of bad working of the appliance due a wrong 
installation or a faulty installation. 

Important:  

Following the international arrangements, during the connexion to the appliance it 

is required a mechanism who allow disconnect the mains all the poles. This mechanism will 
have an overture in the contacts of minimum 3 mm. 
 

Electric connexion 

The general installation of the appliance, whose outlet is located in the back right, should make 
it always by an 

authorized servicer

In accordance with the Directive 73/237EEC for the low-voltage, Directive EMC 89/336 EEC 
and subsequent modifications with the Directive 93/68 for CE mark.  
Check the mains voltage. It must correspond to which indicates the rating plate carrying the 
appliance. It is essential to have a good earth connection. 

Electrical Diagram for each knob: 

 

 

 

Содержание PE-60NS

Страница 1: ...MANUAL DE INSTRUCCIONES INSTRUCTIONS MANUAL PLANCHAS EL CTRICAS ELECTRIC GRIDDLES Modelos Models PE 60NS PE 80NS PE 60NC PE 80NC Idioma Espa ol Language English...

Страница 2: ...Dimensiones exteriores mm Modelos Largo Ancho Alto Potencia Total Kw Fases Amperios A Voltios V Peso Kg PE 60NS 600 438 223 233 4 II 16 6 240 32 PE 80NS 800 438 223 233 5 3 II 22 240 46 PE 60NC 600 43...

Страница 3: ...ivisorias muebles de cocina revestimientos decorativos etc Se aconseja que los mismos sean de material no inflamable Sobretodo hay que asegurarse de que sean respetadas las normas antiincendios Conexi...

Страница 4: ...as instalar el aparato y antes de su utilizaci n es necesario realizar una limpieza de la placa A continuaci n debe tenerse el aparato en funcionamiento durante unos 20 30 minutos para que se quemen t...

Страница 5: ...en la red general La l mpara del piloto esta fundida Soluci n sustituir el piloto El termostato no corta la corriente cuando la placa llega a la temperatura seleccionada Verificar que el bulbo del ter...

Страница 6: ...ting regulations will be respected Guidelines The installation must be done with the following guidelines Anti incident Prescription in force Installation prescription CEI rules Installation The insta...

Страница 7: ...y detergents or abrasive substances Clean both the plate and the collection tray of fats with a degreasing agent in order to prevent the accumulation of fat and this avoid that you can catch fire It i...

Страница 8: ...his appliance must be put in contact with our nearest SERVICE WARNING The manufacturer will not be held responsible for any non approved modifications The manufacturer will not be held responsible for...