background image

13

Reset

In case the «Click - STANDBYKILLER» stops responding for any unknown reason 
please perform the following steps: 

1. Meter Unit: Unplug it from you power outlet, wait a few seconds then plug it  
    back in. 

2. Remote Unit: Press and hold down for 15 seconds.

Wireless Connection

«Click - STANDBYKILLER» operates via a wireless connection with a range of up 
to 10m line-of-sight.  This gives you the ability and fl exibility to use it anywhere in 
your room.  If the two units are too far away from each  other, or the Meter Unit is 
unplugged from the mains outlet, the Remote Unit  will show (- - - -) on the display 
(Fig. 5), 1 min later, the remote unit will turn off automatically. 

FAQ 

Q: 

The display on the Remote unit has turned black after direct sunlight exposure.  It 

is not possible to read anything.  What can I do? (Fig. 6)

A: 

This happens when the display has been exposed to direct sunlight thus warming 

up.  Such heat makes the display turn black.  Put the Remote Unit in a cool place away 
from direct sunlight and it will slowly turn back to normal.

Q: 

The Remote Unit shows (- - - -) on the display, and the Meter unit is plugged in.  

What does that mean?  (Fig.7)

(Fig. 5)

(Fig. 7)

(Fig. 6)

Содержание Click Standbykiller

Страница 1: ...www power save de Deutsch English Italiano Français Español Português Nederlands ...

Страница 2: ...e of Click STANDBYKILLER you should follow the instructions described in this manual carefully Remote Unit The remote unit displays the sum of the power consumption of all connected devices both in standby and under normal operation By pressing from the top on the remote unit the electrical connection to the connected devices in interrupted and so they switch off If it is pressed once again the el...

Страница 3: ...ed on or off Connect the Meter Unit a follows First plug in your device s to the Meter unit then plug in the meter unit to your power outlet on the wall By connecting only one device to the Meter Unit you can measure the power consumption of this device in all operating states including standby mode Fig 2 Fig 2 1 ...

Страница 4: ...ame room at the same time Operation When you use Click STANDBYKILLER for the first time or when the device is kept in the dark for several days the display goes blank Please expose the Remote unit to light for a few minutes After doing so press it down to turn it on Power Saving Mode Push Mode If the Remote Unit is kept in the dark or under low light for several hours it will automatically go in p...

Страница 5: ...oo far away from each other or the Meter Unit is unplugged from the mains outlet the Remote Unit will show on the display Fig 5 1 min later the remote unit will turn off automatically FAQ Q The display on the Remote unit has turned black after direct sunlight exposure It is not possible to read anything What can I do Fig 6 A This happens when the display has been exposed to direct sunlight thus wa...

Страница 6: ...r unit from the wall outlet remove overloading appliances and plug it in again It will return to normal operation Q If the Remote Unit goes off because it was kept in the dark for a long time will the Meter unit switch off too A No The Meter Unit remains on even if the solar power is too small or the Remote is out of range or even switched off More questions and answers can be found on our website...

Страница 7: ... for industrial use or as a safety isolating switch Do not use outdoors and protect from humidity Specifications Remote Unit Power display 0 5 2300 W Power switching control ON OFF On Off time max 1 s Measuring Interval 1 s Power supply solar powered with backup battery Wireless freq power 2 4 GHz 4 mW Wireless range 10m line of sight Protection Rating IP 40 Meter Unit Operating voltage 85 230 VAC...

Страница 8: ...006 EN 62233 2008 EN 55011 2007 EN 55014 1 2006 EN 55015 2006 EN 61000 3 2 2006 EN 61000 3 3 2008 EN 61326 1 2006 EN 61547 1995 A1 2000 EN 61000 6 1 2007 EN 61000 6 3 2007 ETSI EN 300 328 V1 7 1 ETSI EN 301 489 1 V1 8 1 ETSI EN 301 489 17 V1 3 2 In accordance with the following guidelines 2006 95 EC LVD 2004 108 EC EMC 1999 5 EC RTTED _______________________ Dipl Ing FH Karlheinz Knapp License Lic...

Страница 9: ...ec or if an Infratec Serial number is removed or made illegible No Infratec deal agent or employee is authorised to change extend or alter this warranty agreement Infratec AG is not responsible for any special incidental or consequential damages resulting from any breach of this warranty or other legal terms and conditions This is inclusive and not limited to loss of profit downtime goodwill damag...

Отзывы: