Infosec UPS System - 4, rue de la Rigotière – 44700 Orvault – FRANCE - www.infosec.fr
Hot Line : tel : + 33 (0)2 40 76 15 82 - fax : + 33 (0)2 40 94 29 51 - [email protected] – 03 05 04 206 15
10
1 0 . T E C H N I C A L S P E C I F I C A T I O N S
SL 500
SL 700
SL 1000
Technology
High Frequency (40 kHz)
Output form
Modified sinewave
Protection
discharge / overcharge and overload protection
+ fax modem line
Power
450 VA
650 VA
1000 VA
TECHNOLOGY
Power factor
0,45 0,45 0,6
Dimensions
W x D x H (mm)
80 X 176,5 X 230
91 X 280 X 238
Weight kg
3.1 3.3 6.5
PHYSICAL
Output connectors
2 secured outlets
2 RJ11 surge protected outlets
3 secured outlets
2 RJ11 surge
protected outlets
Voltage
110 / 120 V or 220 / 230 / 240 V
220 / 230 / 240 V
INPUT
Voltage range
90-145 V / 170-270 V
170-280 V
Voltage
110 / 120 V or 220 / 230 / 240 V
220 / 230 / 240 V
Regulation
+/- 10 %
OUTPUT
(Battery mode)
Frequency
50 - 60 Hz + / - 1 Hz
Type
12V/4.5AH x 1pc 12V/7.2AH x 1pc
12V/7AH or
12V/7.2 AH x 2pcs
Backup time
(depending on the load)
7 mn
12 mn
30 mn
BATTERY
Recharge time
10 hours to 90 % after complete discharge
Noise level
< 40 dB
ENVIRONMENT
Operating
environment
0° C - 40° C, 20 to 90 % relative humidity
(non condensing)
AC Mode
Green LED lighting
Battery Mode
Green LED flashing every 4 seconds
Low battery at battery
mode
Green LED flashing every second
Fault
Red LED lighting
Battery charging at
AC mode
Red LED flashing every 2 seconds for 30 seconds
INDICATOR
Battery fault at AC
mode (Vbat<12V)
Red LED flashing three times every 2 seconds
Battery mode
Sounding every 4 seconds
Low battery at battery
mode
Sounding every second
Fault
Continuously sounding
Battery charging at
AC mode
Sounding every 2 seconds for 30 seconds
AUDIBLE ARLARM
Battery fault at AC
mode (Vbat<12V)
Sounding three times every 2 seconds
MANUFACTURING Security / Standard
CE – ISO 9001 – PCT Certificate