Examples of steps to follow for setting the parameters:
Step 1 -
Before entering setting mode, make sure that the
UPS is in Stand-by mode (off-charging) and that the battery is
connected. The LCD display is shown as right.
Step 2 -
Press and hold the “Selection” button for 5 seconds to
enter Setting mode.
Step 3 -
Press the “Up” button (ON/MUTE) to switch to "02" of
program list. Then press “Enter” button to enter value setting of
parameter 2. Press the “Up” button to change the value to
“ENA” to enable the programmable outlet function. Then press
“Enter” button again to confirm the setting.
Step 4 -
Press the “Up” button (ON/MUTE) again to switch to
"03" of program list. Then press “Enter” button for setting
programmable outlet time. Push “Up” button to change the
value of backup time according your demand. Then press
“Enter” to confirm the setting.
Step 5 -
Press “Up” button (ON/MUTE) to switch to "00" of program list. Then press “Enter” button
to exit setting menu.
Step 6 -
Disconnect AC input and wait until the LCD display is off. The new setting will be activated
when turning on the UPS again.
3.6 Operating mode and description
Operating
modes
Descriptions LCD
displays
ECO mode
When the input voltage is within voltage
regulated range, UPS will power the
output directly from the mains. ECO is
the abbreviation of Efficiency Corrective
Optimizer. In this mode, when the
battery is full charged, the fan stops
working for an energy saving.