54
drive that it is expected to replace. If the capacity of the spare is less than the
capacity of the drive it is expected to replace, the controller will not proceed
with the failed drive rebuild.
When cabling, follow all the specifications. Pay attention to signal quality and
avoid electronic noise from adjacent interfaces, e.g., do not lay power cords
on optical cables.
When rack-mounted, leave enough slack in the cables so that they do not
bend to a diameter of less than 76mm (3 inches).
Route the cables away from places where it can be damaged by other devices,
e.g., foot traffic or fan exhaust.
Do not over-tighten or bend the cables.
Host-Side Topologies
The primary concern for configuring host-side topologies is to avoid points of failure.
It is therefore recommended that the host ports are connected to at least two HBAs.
NOTE
In order to manage the fault-tolerant data paths and to optimize data throughput on
multiple data paths, it is necessary to apply multipath software or utilities such as
Linux Device Mapper.
Host port channel designation may vary from system to system, please refer to the
following topologies as a guide to create your own connections to suit your needs.
Host-Side Parameters
It is STRONGLY recommended that users use the default settings with their system.
If you feel the need to adjust your host-side parameters, please consult on-site
technical personnel or seek technical support from your vendor.