GUARD SERIES
GUARD SERIES
500AP/ 600AP /800AP 500A/ 600A/800A
2.INSTALLATION
2.1 Inspection
Inspect the UPS upon receipt. The packaging is recyclable; save it for
reuse or dispose of it properly.
2.2 Utility Power
The input power cord on the rear panel needs to plug into a socket on
the wall. Please notice the voltage of utility power should match with the
UPS. (For example, the UPS is 220V, the input utility power should be
220V as well.)
2.3 Connection
The employed equipment’s power cords (such as computer) are
plugged into the sockets on the rear panel.
3.OPERATION
3.1 Switch on with “Green Mode” Function under AC mode
When utility input is connected to the UPS, press “ON” button and keep
pressing less than 3 sec to turn on the UPS. After that, connect the
electrical cords of the equipments that will be used (such as desktop
computer and CRT monitor) to the rear panel of UPS. In order to save
the power, it will also automatically enable the “Green mode” - No Load
(or Light load) shut-down function under backup mode (about 4 minutes
later).
5
ATTENTION:
At backup mode, UPS can be automatically turned off if none
of the connected loads is operating. (Green mode; No Load shut down
function) Once the utility power is normal again, the unit can be waked up
by itself.
CAUTION:
Never connect a laser printer or plotter to the UPS with other
computer equipment. A laser printer or plotter periodically draws
significantly more power than when its idle status, and may overload the
UPS.
3.2 Switch on with “Disabled Green Mode” Function under AC mode
When utility input is connected to the UPS, press “ON” button and keep
pressing until the ”Bi...Bi-Bi” beeps stopped to turn on the UPS. After
that, connect the electrical cords of the equipments that will be used
(such as Notebook computer and LCD monitor) to the rear panel of UPS.
If the load is lighter than 15W, please also refer this function to avoid any
inconvenience cause by “Green Mode” function.
3.3 DC Start with “Green Mode” Function
If the power of UPS isn't supplied by utility but by the internal batteries to
engage the UPS, press the power button and keep pressing less then 3
seconds.
3.4 DC Start with “Disabled Green Mode” Function
If the power of UPS isn't supplied by utility but by the internal batteries to
engage the UPS, press the power button and keep pressing until the
sounds of “Bi Bi-Bi”.
3.5 Switch off
Press the power switch and keep pressing more than 3 seconds to turn
off the UPS.
3.6 Silence
When UPS is under “BACKUP” mode, press power switch more than 1
second to silence the audible alarm. (The function is disable when UPS
is under condition of “LOW BATTERY” or “OVERLOAD”)
3.7 Self test function
Press power switch while utility power is connected, UPS will perform
self-test procedure automatically.