background image

• 32 •

• 33 •

5. Continue to hold the lancing device and gradually 

increase pressure for several seconds.

6. While holding the lancing device on your test site, look 

through the clear tip until a round drop of blood 
appears. 

7. Lift the lancing device straight up; be careful not to 

smear the blood on your testing site.

8. Stick the edge of the test strip to the drop of blood. 

Blood will automatically be drawn up.

REMEMBER

1. Consult with your healthcare professional before using alternate site testing.
2. Choose a different puncture site each time you test. Repeated punctures in the same 

spot may cause soreness and calluses.

3. If bruising occurs at an alternate site or you have difficulty getting a sample, consider 

sampling from a fingertip instead. You may want to review the choice of sites with your 
healthcare professional.

4. Do not share reusable lancing device with anyone including other family members.

Caring for Your GluNEO

®

 Lite System

Cleaning your meter and maintenance 

Blood glucose test meter :
Your blood glucose test meter does not require special maintenance or cleaning. Avoid 
getting dirt, dust, blood, glucose control solution, or liquids on the blood glucose test meter, 
the test port, or data port. Your blood glucose test meter’s operation temperature is 
10~40°C(50~104°F).It is recommended that you store the blood glucose test meter in the 
portable pouch after each use.
A cloth dampened with water and mild detergent can be used to wipe down the outer part of 
the blood glucose test meter. Your  GluNEO

®

 Lite blood glucose test meter is a precision 

instrument. Please handle it with care.

Lancing device :
Clean the lancing device and tips with soap and tepid water. To disinfect the lancing device, 
prepare a disinfectant solution household bleach and water in 1(bleach) : 9(water) ratio. 
Dampen a cloth with this solution and wipe the lancing device thoroughly. Soak only the tip 
for at least 30 minutes in the disinfectant solution. Do not soak the lancing device in liquid. 
Rinse the lancing device and tip with water, and dry thoroughly.
1. For detailed instructions concerning  GluNEO

®

 Lite blood glucose test strips, refer to the 

blood glucose test strip package inserted and found in the blood glucose test strip box.

2. Please store the  GluNEO

®

 Lite blood glucose monitoring  system in a cool and dry area, 

out of reach of children. Do not freeze. For a more accurate test result, avoid testing 
under direct sunlight.

3. Do not soak the blood glucose test meter or blood glucose test strips in water or liquid.
4. Do not subject the meter or blood glucose test strips to excessive heat.
5. Use your meter according to the instructions in the manual.
6. If you need to purchase the lancing device, lancets or blood glucose test strips, contact 

your local representative.

7. Discard the used lancets carefully, to prevent any infection.

CAUTION

Do not test on your forearm or palm when
1. You think you blood glucose is rapidly falling. For example within two hours of 

exercise, rapid-action insulin injection, or an insulin pump bolus.

2. Testing with a fingertip sample may identify hypoglycemia or an insulin reaction 

sooner than testing with a forearm or palm sample.

Содержание GluNEO Lite

Страница 1: ......

Страница 2: ...Blood Glucose Monitoring System for self testing...

Страница 3: ...ional before making any changes to your diabetes management The GluNEO Lite Blood Glucose Monitoring System is for in vitro diagnostic use only Important Information The GluNEO Lite Blood Glucose Moni...

Страница 4: ...based on the GluNEO Lite meter test results without contacting your physician or healthcare professional first 6 Do not assemble or disassemble the blood glucose test meter 7 Keep out of direct sunli...

Страница 5: ...ith GluNEO Lite test strips Do not use during or soon after xylose absorption testing Xylose in the blood will cause interference Before using any product please read all instructions Consult with you...

Страница 6: ...Result System Before Having a Meal After Having a Meal After Taking Medication After Sport Activity Control Solution Symbol Blood Drop Symbol for Test User ID Symbol Test Strip Code Symbol Test Result...

Страница 7: ...ps in new vials or in any other container 3 Immediately replace the vial cap and close tightly after removing any test strips from the vial 4 Make a note of the expiry date which is six months from th...

Страница 8: ...essing and releasing either or buttons to turn the User ID option on off push button Temperature Unit After pressing and releasing either or buttons to set or and push button Alarm time After pressing...

Страница 9: ...e able to check that the meter and test strips are working properly and that you are performing the test correctly It is very important that you perform routine checking to ensure accurate results The...

Страница 10: ...r animal consumption 6 The control solution bottle icon contains letter C so as not to be confused with the medication bottle This will allow you to understand differences between a control solution t...

Страница 11: ...device it provides ultimate safety and comfort for obtaining blood samples An adjustable tip offers 5 different strength levels of skin penetration for individual user s comfort while a lancet ejecto...

Страница 12: ...stem Sliding Barrel Release Button Performing a blood test with your fingertip CAUTION 1 If you do not see the code displayed pull the glucose test strip out of the port and re start the procedure fro...

Страница 13: ...wist the protective cover off Do not discard To obtain a suitable blood samples Before obtaining a blood sample wash your hands with warm clean water and soap Dry hands completely before testing Step...

Страница 14: ...your meter by contaminating it Correct Completely Filled Incorrect Poorly filled Applying Blood Step 4 If you selected to use the User ID option during set up press and button to select the correct U...

Страница 15: ...ucose test meter 3 Please follow the waste disposal regulations on the used lancets and strips imposed by your local authorities Reviewing Your Results The GluNEO Lite meter stores up to 365 test resu...

Страница 16: ...different areas of your body The figure shown above displays the areas where you can test using your GluNEO Lite meter You may test your blood sugar from your forearm upper arm palm ventral palm or do...

Страница 17: ...cemia unawareness To ensure accurate results when lancing your arm forearm or upper arm or palm ventral palm or dorsal hand clean the test site with soap and water Make sure there is no cream or lotio...

Страница 18: ...lood glucose test meter Your GluNEO Lite blood glucose test meter is a precision instrument Please handle it with care Lancing device Clean the lancing device and tips with soap and tepid water To dis...

Страница 19: ...perature After use close cap tightly Make sure the control solution bottle is tightly closed Record the discard date date vial opened plus 3 months on the control solution on the bottle Do not use if...

Страница 20: ...hcare professional NOTE 1 Make sure your date and time are correct after changing your battery 2 Please recycle or dispose of used batteries using your local battery collection systems and in complian...

Страница 21: ...movetheBloodglucosetest strip from the GluNEO Lite Blood glucose test meter Dispose of used Blood glucose test strip in a sealed container with your household waste in accordance with local regulation...

Страница 22: ...ommenda tions Perform a control solution test to check the accuracy of your test strip Message What it means Action required Trouble shooting Test result is higher than 600 mg dL 33 3mmol L Check the...

Страница 23: ...t this instrument will be free from defects in workmanship for 3 years from the date of original purchase Limitations of Warranty This warranty is subject to the following exceptions and limitations 1...

Страница 24: ...not Freeze Display Type LCD Reading Time 5 seconds Sample Type Capillary and or venous whole blood Symbol Reference Consult Instructions for use Use By date This product fulfills the requirements of D...

Страница 25: ...Memo Memo...

Страница 26: ...Memo...

Отзывы: