Introduction to the Infoblox 4005 Series

This guide provides an overview of the Infoblox 4005 Series appliances, and explains how to install and configure the system. The Infoblox 4005
Series includes the Infoblox Trinzic TE-4015 and TE-4025, the Network Insight ND-4005, and the Trinzic Reporting TR-4005. This guide
describes the features for each appliance model, the hardware elements, and installation and deployment information common to all models in
the Infoblox 4005 series. Consult the respective sections below for introductory descriptions of the unique features for your specific appliance:

Infoblox Trinzic TE-4015 and TE-4025 Product Overview
Network Insight ND-4005 Product Overview
Infoblox Reporting TR-4005 Product Overview

You configure and manage Infoblox 4005 Series appliances through the easy-to-use Infoblox GUI, Grid Manager, that works seamlessly in
Windows, Linux, and Mac environments using standard web browsers. For more information about Grid Manager, refer to the Infoblox NIOS

.

Administrator Guide

The 4005 Series appliances are Class A and Class B (with limits) digital appliances per FCC regulations, and are RoHS compliant, and WEEE
compliant.

Infoblox Trinzic TE-4015 and TE-4025 Product Overview

The Infoblox Trinzic TE-4015 and TE-4025 are high performance network appliances that provide core network services, including DNS (Domain
Name System), DHCP (Dynamic Host Configuration Protocol), IPAM (IP Address Management), and NTP (Network Time Protocol). They may
operate as a Grid member or as a Grid Master, and can operate with a second Trinzic appliance of the same model in high availability (HA) mode.
You configure and manage the Trinzic appliances through the Infoblox Grid Manager.

Key features of the TE-4015 and TE-4025 include the following:

Support for Grid management and all administrative features for Infoblox IPAM, DNS, DDNS, and DHCP.
Optional 10GbE or 1GBE SFP+/SFP system configurations for fiber or copper support.
High availability support.
LOM (Lights Out Management) support.
Field replaceable hard disk drives and fan modules.
Hot-swappable AC supplies
Optional DC power supplies

CC and FIPS for TE-4015, TE-4025, TE-V4015, and TE-V4025

The Infoblox Trinzic TE-4015, TE-4025, TE-V4015, and TE-V4025 appliances can be made compliant with CC (Common Criteria) and FIPS
(Federal Information Processing Standard) 140-2 security standards. Both CC and FIPS give assurance that the product satisfies a set of
internationally recognized security measures. CC is a set of rules and specifications to evaluate the security of Information Technology (IT)
products. FIPS is a U.S government computer security standard that is designed to validate product modules that use cryptography. This is
necessary to maintain the integrity and confidentiality of the end-user information that is stored, processed, and transferred by the product
module. To ensure that your appliance is CC and FIPS compliant, make sure that your hardware and software settings match the evaluated
configuration that was certified for both CC and FIPS. For information about how to configure CC and FIPS, refer to the Infoblox NIOS

.

Administrator Guide

Infoblox provides tamper evident FIPS labels that you must affix on the HDD cover, all PSU and fan canisters, over the IPMI port of the appliance
to make it FIPS compliant. You must install the FIPS tamper evident labels correctly onto the device for compliance with FIPS. This label is valid
for Infoblox Trinzic TE-4015 and TE-4025 appliances only. Note that these labels are not required for CC.

Clean the chassis before affixing tamper evident FIPS labels. Apply these labels as shown in the figures below:

FIPS label

Install a sticker on the drive bay cover as shown in the picture

Содержание ND-4005

Страница 1: ...Infoblox Installation Guide 4005 Series Appliances Trinzic TE 4015 and TE 4025 Network Insight ND 4005 Trinzic Reporting TR 4005 ...

Страница 2: ...e Infoblox 4005 Series Appliance 12 2 1 Connecting To The Appliance 14 2 2 Auto Provisioning NIOS Appliances 14 2 3 Specifying Appliance Settings 15 2 4 Infoblox NIOS CLI 16 3 Installing the Infoblox 4005 Series Appliance 17 3 1 Rack Mounting Procedures 17 3 2 Powering the Appliance 21 3 3 Cabling the Appliance to a Network 21 4 Field Replaceable Units 21 4 1 Managing the Disk Subsystem 22 4 2 Har...

Страница 3: ...5 and TE 4025 include the following Support for Grid management and all administrative features for Infoblox IPAM DNS DDNS and DHCP Optional 10GbE or 1GBE SFP SFP system configurations for fiber or copper support High availability support LOM Lights Out Management support Field replaceable hard disk drives and fan modules Hot swappable AC supplies Optional DC power supplies CC and FIPS for TE 4015...

Страница 4: ...rved Install a sticker on both of the back corners of the top cover as shown in this picture Install stickers for each of the fans into the chassis as shown in this picture Install a sticker for each power supply module as shown in this picture ...

Страница 5: ...E or 1GBE SFP SFP system configurations for fiber or copper support Management through the Infoblox Grid LOM Lights Out Management support Replaceable hard disk drives and fan modules Hot swappable AC or DC power supplies in a redundant 1 1 configuration Note The Network Insight ND 4005 does not support HA operation and acts only as a Grid member Infoblox Reporting TR 4005 Product Overview The Inf...

Страница 6: ...below The hard disk drives are concealed under a removable drive bay door You must remove the door to access the hard disk drives as shown in the For more information see and figure Ethernet port LEDs Interface Connector Pin Assignments Table below describes the Infoblox 4005 Series front panel components Front Panel Components Component Description Hard Disk Drives Four hot swappable Infoblox dat...

Страница 7: ...ort for a console connection to change basic configuration settings and view basic system functions through the CLI command line interface If your system lacks a DB 9 serial port use a properly grounded USB to Serial dongle for connection to the serial console port If the dongle is connected to a laptop the laptop also must be properly grounded Failure to do so may cause damage to the serial conso...

Страница 8: ...the internal Ethernet ports the Infoblox 1GbE SFP or 10GbE SFP ports replace the functionality in the original system MGMT LAN1 HA and LAN2 ports thereby disabling the built in MGMT LAN1 HA and LAN2 ports 10GbE support accepts Infoblox provided SFP 10GbE Short Range and Long Range transceivers Cisco SFP Direct Attach 10GSFP Cu or HP HPJ9283B SFP Direct Attach 10GSFP Cu transceivers You may mix med...

Страница 9: ...net ports are auto sensing and automatically adjust to standard straight through and cross over Ethernet cables DB 9 Console Port and RJ 45 Port Pinouts DB 9 Connector Pin Assignments Pin Signal Direction 1 not used 2 Receive Input 3 Transmit Output 4 DTE Ready Output 5 Ground 6 DCE Ready Input 7 RTS Request to Send Output 8 CTS Clear to Send Input 9 not used RJ 45 Connector Pin Assignments Pin 10...

Страница 10: ...affic Appliance Rear Panel The Infoblox 4005 Series appliances ship with dual AC power supplies and six fan modules The power supplies and fan modules are field replaceable The power supplies are also hot swappable so you can replace any one of them at a time without disrupting the operations of the appliance Infoblox 4005 Series Rear View Rear Panel Components Component Description Fan Modules Si...

Страница 11: ...ectrical power budgets include the following Use of a single power supply or 1 1 redundant PSU power supply unit configuration see Appliance Rear Panel 1 GbE SFP network interface card see SFP SFP Interface Support 10 GbE SFP network interface card see SFP SFP Interface Support You may choose to order a field replaceable power supply to upgrade your appliance to a 1 1 redundant configuration Doing...

Страница 12: ...sing the Infoblox 4005 Series Appliance The management system is the computer from which you configure and monitor the Infoblox appliance You access the appliance from the management system remotely across an Ethernet network or directly through a serial cable After completing the steps in Cabling the Appliance you can open an HTTPS connection to the appliance and access the Infoblox Grid Manager ...

Страница 13: ...0 x 9 x and 8 x Mozilla Firefox 32 x 31 x 25 x 21 x 16 x and 10 x Google Chrome 37 x 36 x 30 x 27 x 22 x and 16 x Microsoft Windows XP SP2 Microsoft Internet Explorer 7 x and 8 x Mozilla Firefox 32 x 31 x 25 x 21 x 16 x and 10 x Google Chrome 37 x 36 x 30 x 27 x 22 x and 16 x Red Hat Enterprise Linux 7 x Mozilla Firefox 32 x 31 x 25 x 21 x 16 x and 10 x Google Chrome 37 x 36 x 30 x 27 x 22 x and 1...

Страница 14: ... using the NIOS CLI Note For serial port connections use only a properly grounded USB to Serial dongle If the dongle is connected to a laptop the laptop also must be properly grounded Failure to do so may result in damage to the serial console port of the Infoblox appliance Infoblox is not responsible for such damage Connect a console cable from the console port of the management system to the con...

Страница 15: ...n the appliance to the Grid through the remote console You can login to the remote console using the user name and the Grid shared secret as the password admin Note When auto provisioning is disabled for an appliance and the network address is not preserved auto provisioning will be re enabled and a DHCP lease request is sent to the DHCP server if you reset the appliance using the CLI command or r...

Страница 16: ...in Password Local Date Time and Time Zone or NTP Server IP Address On the last screen of the wizard click The Grid Manager application restarts If you have configured an HA pair use the VIP address Finish when you make an HTTPS connection to the HA pair Infoblox NIOS CLI The NIOS CLI allows you to configure and monitor the appliance using a small set of Infoblox commands Some tasks such as resetti...

Страница 17: ...all the appliance in an environment that allows open air to the front and back of the appliance Do not obstruct the appliance or block air flow going from the front to the back of the appliance Rack Mounting Procedures The Infoblox 4005 Series appliances mount into a standard 19 48 cm equipment rack The appliances ship with accessory kits that contain the following a pair of rack slide brackets an...

Страница 18: ...extend through the entire depth of the equipment rack Exercise caution when withdrawing the appliance from its position in the equipment rack For a four post rack mount you combine the bundled pair of rack ears with a pair of chassis rack rails providing up to 600mm depth in a four post rack The chassis rack rail assembly is bundled with the appliance at time of purchase This kit also is provided ...

Страница 19: ...s kit is provided as a field replaceable unit For more information see International AC Power Cords The adjustable rail kit is designed for tight vertical spaces on the interior of a four post rack allowing for appliance installation in restricted rack spaces including 2U of available rack space The figure below shows a rail assembly Sliding Rack Rail assembly The adjustable rack rail kit includes...

Страница 20: ...of designated space Extend the rack rail assembly backwards align the mounting holes on the chassis slide rails with the required cage nuts and fasten the back end of the rack rail to the two cage nuts on the rear post of the designated space As noted the rack rail assembly has an extension range from the minimum of 600mm to a maximum of 900mm Perform Steps 2 and 3 for the second rack rail assembl...

Страница 21: ...work Connectivity By default an Infoblox appliance automatically negotiates the optimal connection speed and transmission type full or half duplex on the physical links between its LAN1 LAN2 HA and MGMT ports and the Ethernet ports on a connecting switch Occasionally the Infoblox appliances may fail to auto negotiate that speed and type and instead connect at lower speeds of either 100 or 10 Mbps ...

Страница 22: ... monitor the disk subsystem through the Grid Manager and the front panel LEDs for the disk drives You can also view disk status by using the CLI command show hardware_status To see a detailed status report log in to the Grid Manager and from the tab select the appliance and then click the Grid Grid Manager Detailed Status icon For more information on the panel refer to the Detailed Status Infoblox...

Страница 23: ... Manager Detailed Status Installing disks that are not qualified and shipped from Infoblox could cause failures in the appliance You can access the disk drives from the front of the appliance Each disk drive weighs about 2 pounds 90 kg You can remove or replace a defective drive without interrupting appliance operations or network services To remove a disk drive Identify and verify the failed driv...

Страница 24: ...t a time You can remove a second disk only after you replace the first disk and the array completes its rebuilding process Do not remove a disk drive if the array is rebuilding This could result in an appliance failure Verify the status of the array before removing a disk drive You can hot swap a drive while the appliance remains in production Some conditions may require powering down the applianc...

Страница 25: ...trator Guide Replacing Fan Modules The Infoblox 4005 series appliances ship with five hot swappable fan modules so you can replace a fan module without interrupting appliance operations Each fan has an air vent that allows warm air to flow out of the appliance If a fan stops operating due to removal or a failure the appliance continues to run and generates an SNMP trap You can also monitor the sta...

Страница 26: ...ick into place Reconnect the power cable If the power supply is fully seated powered on and operating properly the LED glows steady green Changing DC Power Supplies In DC power configurations the Infoblox 4005 series appliances ship with two redundant hot swappable auto switching DC power supplies To replace an Infoblox 4005 series DC power supply do the following Disconnect the DC power cable fro...

Страница 27: ... its original AC power supplies RMA shipment before back to Infoblox Keep your DC power supplies in your facility until you receive your replacement appliance International AC Power Cords Infoblox offers replacement AC power cords for international markets as listed For availability contact your Infoblox sales representative below International AC Power Cords Infoblox Part Number International Ite...