![Infoblox ND-2200 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/infoblox/nd-2200/nd-2200_installation-manual_2057163014.webp)
Introduction to the Infoblox 2200 Series
14
Infoblox Installation Guide
Infoblox 2200 Series
Appliance Rear Panel
The Infoblox 2200 Series appliances ship with dual AC power supplies and five fan modules. The power supplies
and fan modules are field replaceable. The power supplies are also hot-swappable so you can replace any one of
them at a time without disrupting the operations of the appliance.
Figure 6
Infoblox 2200 Series, Rear View
Table 2
Rear Panel Components
Component
Description
Fan Modules
Five field replaceable fan modules to help maintain optimum operating temperature. Each fan
has an air vent that allows warm air to flow out of the appliance. Do not obstruct.
UID LED
Blue = UID is activated through pressing the UID button on the appliance or through the Grid
Manager or CLI command
Dark = UID is deactivated
When UID is activated, the LCD on the front panel blinks at the same time.
UID Button
The unit identification button. When you press the UID button, the LCD panel on the front
panel blinks and the UID LED on the rear panel glows blue. In a rack environment, the UID
feature enables easier location of a server when moving between the front and rear of the
rack. You can also identify the appliance through the Grid Manager and CLI command.
Grounding Post
For DC installations, you securely connect a grounding wire to the chassis and to earth
ground, which typically is the equipment rack on which you install the appliance. The
mounting nut is placed on the grounding post for convenience. Remove the mounting nut,
place the grounding wire connector onto the grounding post and replace the mounting nut.
Ensure that it is snug.
Power Supplies
Each of the two redundant power supplies has a three-prong power outlet for connecting the
appliance to a standard AC (Alternating Current) power source.
Power Outlets
Fan Module 1
Power Supply 2
Fan Module 2
Fan Module 3
Fan Module 4
Fan Module 5
Power Supply 1
UID LED
UID Button
Grounding Post (DC only)
Содержание ND-2200
Страница 16: ...System Environmental and Power Specifications For the Infoblox 2200 Series Platforms 16 ...
Страница 24: ...Cabling the Appliance to a Network For the Infoblox 2200 Series Platforms 24 ...
Страница 44: ...Infoblox 2200 Series International AC Power Cords For the Infoblox 2200 Series Platforms 44 ...