8. IR Cable Pin Assignment
IR
RECEIVER
IR
BLASTER
- 10 / 25 -
9. EDID Management
This Matrix has 21 factory defined EDID settings, 2 user-defined EDID modes and 16 copy EDID
modes. You can select defined EDID mode or copy EDID mode to input port through on-panel
button, RS-232 control or Web GUI.
On-panel button operation:
On the initial OLED display screen, press “MENU” button to enter
the EDID setting interface, press “UP/DOWN” button to select the required EDID, and press
the “ENTER” button to enter “Copy to Input:” interface. Then press “UP/DOWN” button to select
the input port you need to set, and press “ENTER” button again to confirm this operation.
RS-232 control operation:
Connect the Matrix to PC with a serial cable, then open a Serial
Command tool on PC to send ASCII command “s edid in x from z!” to set EDID. For details,
please refer to “EDID Setting” in the ASCII command list of “11. RS-232 Control Command”.
Web GUI Operation:
Please check the EDID management in the “Input page” of “10. Web
GUI User Guide”.