Software functions

 

Face recognition 

Intelligent human recognition, max 50 people per frame 

Measurement solution 

Multiple spots, human face auto-tracking measurement 

High temperature alarm 

High temperature exceeding alarm, support alarm window output, 

auditable alarm, GPIO alarm 

Preview mode 

Visual / thermal 

Data analysis 

1TB historical data storage, retrieve in face mask, alarm, time 

Body temperature correction 

Intelligent human body temperature correction 

Flux 

200 People/minute 

Remote access 

Support web remote access, achieving preview in real-time, alarm in 

real-time 

Network connection 

Support 4 channel cameras access in 

ID identification (optional) 

Support local face library comparison 

Environment adaption

 

Working temperature 

-10℃

50℃ 

Storage temperature 

-20℃

+65℃ 

Humidity 

5

95%,    non-condensing 

Note: 

(1)

 

Precise measuring with blackbody @ambient temperature of 16℃

32℃ (indoor, windless, without 

ambient temperature jump) 

 

 

 

 

 

 

 

 

 

Содержание ITSII 300

Страница 1: ...ITS 300 AI Thermal Imaging Temperature Screening System Quick User Guide V1 0 1 Yantai IRay Technology Co Ltd...

Страница 2: ...is used as a guide The photos graphics diagrams and illustrations provided in the manual are only used to explain which may be different from the specific product Please refer to the real object We t...

Страница 3: ...d Connecting Camera 5 3 3 Blackbody Specification and Installation 7 3 4 Site Layout Solution 8 3 5 Site Installation and Layout Considerations 9 3 6 Parameter Setting Guidance 10 4 Software User Guid...

Страница 4: ...g System developed for the epidemic situation The system combines high precision thermal temperature measurement and accurate face recognition technology which can quickly detect pedestrians of abnorm...

Страница 5: ...2 1mrad Visual Imaging Resolution 1920 1080 Focal length 4 7 141mm HFOV 60 5 2 3 Temperature Measurement Measurement range 0 60 Accuracy 1 0 3 target temperature of 33 42 ambient temperature of 16 32...

Страница 6: ...nalysis 1TB historical data storage retrieve in face mask alarm time Body temperature correction Intelligent human body temperature correction Flux 200 People minute Remote access Support web remote a...

Страница 7: ...ry List Before installation please make sure that the equipment in the package is intact and all parts are available Optional package Prepared by users Displayer resolution 1920 1080 HDMI cable Tools...

Страница 8: ...p of the product for fixing the camera to the adapter or bracket Figure 3 1 Structure of Camera Take the thermal camera mounted on a tripod as an example as follows Remove the tripod head counterclock...

Страница 9: ...amera height according to the deployment scenario 1 7m 2m is appropriate Figure3 3 Camera Installation Connect the DC 12V power cable and network cable to the DC in port and RJ45 port of camera Figure...

Страница 10: ...ment temperature 0 40 Temperature range Ambient temperature 5 50 Temperature resolution 0 1 Accuracy 0 2 35 Emissivity 0 97 0 02 Settling time 5min Temperature stability 0 1 0 3 h Effective radiant su...

Страница 11: ...height and distance of infrared measurement thermal imaging camera and external reference blackbody are determined according to the specific application scene and specific model but the following pri...

Страница 12: ...area of the camera market and shall not be shielded by pedestrians Figure 9 Infrared Imaging on PC Environmental requirements The infrared temperature measuring camera is arranged in an environment w...

Страница 13: ...om with a constant temperature from a hot cold outdoor environment at this time a long enough channel needs to be reserved to allow the subject s body surface temperature to gradually stabilize before...

Страница 14: ...etwork cardd1 192 168 1 124 Network card2 192 168 1 125 4 2 System Login There are two ways to login ITS II system one is login local server via GUI and another is login Web server via Explorer Figure...

Страница 15: ...ccess Server or else it will warning login error 5 Troubles Shooting Troubles Shooting Fault description Possible Causes Method of exclusion Boot failure Power connector is loose Check whether the pow...

Страница 16: ...ent light etc or it may damage the lens or detector Equipment used indoors should not be installed exposed to rain or very wet areas Do not place the equipment in an environment with corrosive gas whi...

Страница 17: ...not squeeze the lens surface wipe liquid also can not dip in too much make sure the cloth is wet but wipe liquid can not be extruded If still not clean replace the cloth and repeat operation 6 3 Safe...

Страница 18: ...V1 0 1 15 Yantai IRay Technology Co Ltd 11th Guiyang Street YEDA Yantai 264006 P R China Fax 86 0535 3410610 Email sales IRaytek com Address 11th Guiyang Street YEDA Yantai Shandong Province...

Отзывы: