background image

InfiRay Outdoor 

 

EYE III Series

 

  User Manual                                                                                                                                                                                                            www.infirayoutdoor.com

 

All rights reserved and shall not be copied and distributed in any form without written permission.                                                                                                      - 8 -

 

 

 

Never use a damaged or modified charger.

 

 

Don’t leave battery unattended when charging. Don’t leave the device 

with a charger connected to the mains longer than over 24 hours after 

full charge.

 

 

Do not expose the battery to high temperature or to a naked flame. 

 

 

Don’t connect external device with a current consumption that exceed 

permitted levels.

 

 

The battery is short circuit protected. However, any situation that may 

cause short-circuiting should be avoided.

 

 

Don’t dismantle the battery from the device. 

 

 

The battery capacity may decrease when using the battery in negative 

temperature, that is normal, not a defect.

 

 

Avoid using the battery at the temperature above the temperature 

shown in the table, this may decrease the battery’s life.

 

 

If the thermal imaging monocular is not used for a long time, recharge 

the device every 2 months at least and charge to 40%-50% power, then 

store the device in a dry and ventilated environment. 

 

 

Partial charging the battery is necessary if the battery is planned to be 

idled for long time. Avid fully charged or discharged.

 

 

Keep the battery out of the reach of children.

 

 

Operation 

 

Open the lens cap 

(9)

 to power on the device, and the startup logo will 

be displayed on the device screen in 1 second. Also, the EYE III will be 

powered on with a long press of the 

Controller (3)

 for 3s.

 

 

 

When  an  infrared  image  is  displayed  in  the  eyepiece,  the  thermal 

imaging monocular enters the operating status.

 

 

Rotate the diopter adjustment knob 

(2) 

to adjust the resolution of the 

icon on the display. The diopter adjustment knob is used to adjust the 

eyepiece diopter for users with different degrees of myopia.

 

 

Shortcut menu:

 On the home screen, press the 

Controller (3)

 to 

open the shortcut menu, and set the image mode (        ), scene mode 

(          ), screen brightness (          ), and image sharpness (          ). Rotate 

the 

Controller (3)

 to switch between different functions on the shortcut 

menu, and press the 

Controller (3)

 to set parameters. 

 

 

Main menu: O

n the home screen, press and hold the 

Controller (3)

 to 

enter the main menu interface for more functions. Rotate the 

Controller 

(3)

 to switch between different functions on the main menu, and press 

the 

Controller (3) 

to select the option.

 

 

Photographing / Video recording: 

On the home screen, briefly press 

Содержание E3 Max

Страница 1: ...InfiRay Outdoor EYE III Series User Manual www infirayoutdoor com All rights reserved and shall not be copied and distributed in any form without written permission 0...

Страница 2: ...ice to access the battery The battery is not meant to be replaced by the end user Only use the battery charger included in the delivery package Only charge the device at temperatures ranging between 0...

Страница 3: ...hen you purchase a corresponding new product The proper disposal of this product serves to protect the environment and prevents possible harmful effects on human beings and their surroundings which ma...

Страница 4: ...no visible damage Test to see if the device displays a clear undisturbed image Check that the settings for the device are correct See the notes in the section Operation Installing removing the battery...

Страница 5: ...1 4 Detection Range m Target size 1 7m 0 5m P n 99 1300 1800 1800 Display Specifications Type OLED Resolution 1440 1080 Battery Power Supply Battery Type Capacity Output Voltage Built in Li ion batter...

Страница 6: ...t It requires no external light source Even targets hidden behind obstacles such as branches grass and shrubs can be observed The EYE III series thermal imaging monocular is light and easy to carry sm...

Страница 7: ...iclockwise Controller Powered off Power on the device Home screen Open the shortcut menu Open the main menu Digital zoom in Digital zoom out Standby mode Wake up the device Wake up the device Menu int...

Страница 8: ...etic port 5 is red The power indicator 6 is on only in the charging status When the power indicator 6 turns green the device is fully charged When charging a lighting icon will appear inside the batte...

Страница 9: ...ent Partial charging the battery is necessary if the battery is planned to be idled for long time Avid fully charged or discharged Keep the battery out of the reach of children 8 Operation Open the le...

Страница 10: ...the Camera button 4 twice to standby the device If there is no operation performed for 30 minutes the product will automatically shut down 9 Status Bar The status bar is located at the top of the ima...

Страница 11: ...ation Auto Calibration Device will calibrate automatically according to the software algorithm There is no need to close the lens cover the internal shutter covers the sensor Turn on off the auto cali...

Страница 12: ...The images taken and the videos recorded are stored in the built in memory space in the format of PIC_HHMMSS jpg image and VIDEO_HHMMSS mp4 video with HHMMSS indicating hour minute second The maximum...

Страница 13: ...ication is displayed in the status bar 13 Shortcut Menu Function On the shortcut menu you can quickly adjust basic configurations of commonly used functions including the image mode scene mode screen...

Страница 14: ...rotate the Controller 3 and vice versa Press briefly the Controller 3 to adjust the current parameters or enter the sub menus In all menu interfaces press and hold the Controller 3 to save and exit to...

Страница 15: ...Menu interface Rotate the Controller 3 to select the Wi Fi option Press briefly the Controller 3 to turn on off the Wi Fi function When Wi Fi is on the default password is prompted for 3s behind Wi Fi...

Страница 16: ...Interconnection function is on and vice versa PIP Turn PIP function on off Press and hold the Controller 3 to enter the Main Menu interface Rotate the Controller 3 to select the PIP option Press brie...

Страница 17: ...y collected during video recording Image hue Set the image hue Press and hold the Controller 3 to enter the Main Menu interface Rotate the Controller 3 to select the Image Hue option Press briefly the...

Страница 18: ...pass calibration interface An icon like a triaxial coordinate system appears on the screen In the 15 seconds rotate the scope along the three axes indicated by the icon with each axis rotating at leas...

Страница 19: ...firmware update function Rotate the Controller 3 to select Yes or No and press the Controller 3 to confirm the selection When select Yes it will automatically search for the update file in the folder...

Страница 20: ...Sharpness level 3 Magnification 1 Auto Calibration On Image Hue C Ultra Clear Mode Off Wi Fi Off Wi Fi Password 12345678 Interconnection Off PIP Off Microphone Off Compass Off Info Show device informa...

Страница 21: ...t supports to control the device via the InfiRay Outdoor App downloaded in the mobile device Setting Wi Fi Name and Password The name and password of the Wi Fi in EYE III series can reset on the InfiR...

Страница 22: ...nection Between EYE III Two EYE III devices could also be interconnected manually First turn on the Wi Fi function on one device And turn on the interconnection function on the other device For faster...

Страница 23: ...ler 3 to enter the Main Menu interface Rotate the Controller 3 to select the Firmware Update option Short press the Controller 3 to enter the submenu of the firmware update Rotate the Controller 3 to...

Страница 24: ...ease may be used for cleaning process Clean the electric contacts and battery slots on the device using a non greasy organic solvent Check the glass surface of the eyepiece and lens If necessary clear...

Страница 25: ...th the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harm...

Отзывы: