background image

 11

 

Direct operation via mouse or touch-screen can be operated here. 

 

3.5 WEB Page Configuration 

This section will introduce the Web login, WEB User Management 
and Upload and Backup 

 

3.5.1 WEB Login 

To ensure system security, user login is used when access V2125 
web server. User should enter the right “Username” and “Password” 
when access. 

 

WEB Login of V2125 Keyboard: 

1)

 

Connect V2125 keyboard to relevant network properly; 

2)

 

Open IE browser and input the IP address of the 
keyboard (like http://192.168.0.2, subject to the actual 
application) to enter the Login Interface. 

3)

 

Select "Login" 

 

Figure 3-10 Login Interface 

 

4)

 

Login with default Username "INFINOVA" and 
Password "INFINOVA" (modify password in time to 
assure security). The following system interface will be 
displayed as below: 

 

Figure 3-11 Home Page of Web Interface 

 

Of which, 

Log Off:

 Write off the current login and return to login interface; 

Sync Time:

 Synchronize with local PC time; 

Help:

 Obtain detailed solutions. 

 

3.5.2 WEB User Management 

To assure system security, user needs to input the correct Username 
and Password to access Web Server. User can browse, modify and 
delete user information in "Webuser Management" menu; the menu 
is only available for Super User. 
Click "Webuser Management" to display all user information. Click 

 to modify user's password; Click 

 to delete user, but 

super user can not be deleted; Click 

  to add new username 

and password.   

Note:

 the string length is within 20 characters. 

 

Figure 3-12 Browse User Interface 

 

Click 

 to enter user edit interface, such as clicking 

"INFINOVA" to enter user edit interface to modify password of 
INFINOVA. 

 

Figure 3-13 Edit Webuser 

 

Click 

  in menu lists, and then enter Username, Password, 

Содержание V2125 Series

Страница 1: ... audio communication between keyboard to keyboard and among IP front end devices can be realized V2125 series system keyboards can establish Ethernet or RS 232 communications with Infinova series matrix switching systems Eight different baud rates are provided to meet various requirements The system keyboards also feature built in RS 422 485 and Manchester control code generators for direct contro...

Страница 2: ......

Страница 3: ...em keyboards all comply with Part 15 of the FCC rules Operation is subject to the following two conditions z This device may not cause harmful interference z This device must accept any interference received including interference that may cause undesired operation V2125 series system keyboards have been tested and found to comply with the limits for Class A digital device pursuant to Part 15 of t...

Страница 4: ...nded by manufacturer z Position power source and related wires to assure they will be kept away from ground and access way z Refer all service matters to qualified personnel z Save product packaging to ensure availability of proper shipping containers for future transportation Indicates that the un insulated components within the product may carry a voltage harmful to humans Indicates operations t...

Страница 5: ...Splitting and Calling Sub screen 14 4 5 1 Screen Splitting 14 4 5 2 Select Sub screen 14 4 6 Operation Mode of Matrix 14 4 6 1 Camera Control 14 4 6 2 Running a Tour 14 4 6 3 Calling a Preset 15 4 6 4 Calling a Salvo 15 4 6 5 Calling a Pattern 15 4 6 6 Activating Auxiliary Relays 15 4 6 7 Acknowledging an Alarm 15 4 7 Program Mode of Matrix 16 4 7 1 System Reset 16 4 7 2 Arranging Monitor Display ...

Страница 6: ......

Страница 7: ...lish Ethernet or bi directional RS 232 communications with Infinova series matrix switching systems Eight different baud rates are provided to work with different major matrix switcher controllers They also offer five LEDs indicating running status of the system The LEDs from left to right are POWER RS232 RS 485 MANCHESTER and ETHERNET 1 2 Model V2125 System keyboard 7 0 LCD screen 3 D joystick DV...

Страница 8: ...em Keyboard Rear Panel Communication ports on the rear panel of V2125 series system keyboard are shown as Figure 2 1 1 In serial number the three pins respectively labeled B W and S are used for direct control of decoders or dome cameras via Manchester control code 2 In serial number the three pins respectively labeled G T and T are provided for direct control over decoders or dome cameras or DVR ...

Страница 9: ... shall be 4 to 5 receivers whose ID fall within the scope of 1 64 in addition V2125 can work with V2412M series to provide control of up to 16 receivers Please refer to V2412M series user documentation for more information Figure 2 4 and Figure 2 5 shown below illustrate the connections with the receivers Figure 2 4 Control Receivers via Manchester Code P O W E R C O D E R E F P A N 1 P O T P A N ...

Страница 10: ... 230VAC 50Hz NC NO CN RS485 T T GND DATA LINE V2015 Hub Communication ports on V2125 rear panel T T G B W S ETHERNET RS232 V2125 keyboard Figure 2 7 Connect V2015 via Ethernet Communications 2 5 Using Port Expanders In some applications V2405A 4 series Port Expanders might be required to expand the original RS 232 ports of the matrix switching system A single port expander can expand one original ...

Страница 11: ...low information before system operation and programming All below menus are operated by mouse or screen touch 3 1 LCD Display Main Interface After the keyboard starting when the power is on video interface will appear soon while the size of video interface is smaller than LCD s Analog or network video interface will be displayed in normal conditions while NO VIDEO will be displayed when the video ...

Страница 12: ... The lower left corner will display indicating that the network is disconnected either in Matrix or DVR mode 3 2 System Parameter Setup Click System Para to display the following validation menu for PIN code as shown below Enter system setup menu after the PIN code is entered Super PIN code is 999999 by default PIN code modification is permitted in System Para menu Setup like Basic Para Input Mode...

Страница 13: ... Click OK to save the settings otherwise click Cancel Note PIN code is fixed as 6 digits Super PIN code password is 999999 User can enter the System Parameter to set the menu with the Super Password when the user defined password is forgotten Then setup interface in WEB page is displayed below Figure 3 1 Basic Parameter Setup Keyboard function mode can be set here DVR mode or Matrix Dome Mode as w...

Страница 14: ...own list Matrix default IP address 192 168 0 1 Note Factory default set of V2125 is Matrix mode Protocol I Baud Rate 1200 When Protocol II is selected communication method defaults to RS422 Baud Rate 9600 Configuration interface at WEB page is shown below Figure 3 3 Matrix Control Setup 3 2 4 Dome DVR Control Click or touch Dome DVR Control to enter Dome DVR control menu If DVR Mode is selected in...

Страница 15: ... Audio Intercom Device Type with New System Keyboard or IP Front end optional aim to realize audio intercom among keyboards and from keyboard to IP front end Currently N series SD front ends and N series encoders under Infonova protocol are supported 3 Video IP set the IP address of the devices from which the video sources with 192 168 0 3 by default Currently N series SD front ends and N and K se...

Страница 16: ...records While once the records excess 10000 system will update the latest records and delete earlier records as shown below History management includes search history and delete history at WEB page Search History Figure 3 8 Search History User can search or print keyboard operations or set content for a time period Delete History Figure 3 9 Delete History User can delete keyboard operations or set...

Страница 17: ...erface will be displayed as below Figure 3 11 Home Page of Web Interface Of which Log Off Write off the current login and return to login interface Sync Time Synchronize with local PC time Help Obtain detailed solutions 3 5 2 WEB User Management To assure system security user needs to input the correct Username and Password to access Web Server User can browse modify and delete user information in...

Страница 18: ...3 15 Upload and Backup User can update V2125 keyboard through the latest software package obtained from Infinova s website and other place Under the condition of not changing current system configuration user could update the system through webpage but user shall restart the system to make the software took effect when upload finished After finishing parameter configuration and saving them to FLAS...

Страница 19: ...ommunication Route the Ethernet port on the rear panel of V2125 via Hub to the Ethernet port on the matrix switching system as shown in Figure 4 2 Figure 4 2 Connect V2125 with HUB 4 2 User Login To assure system security certain matrix models V2040 for example require a User Login procedure to access system functions Under such circumstances it will prompt Enter Username and Enter Password messag...

Страница 20: ...mber 4 Press the MON key to call the sub screen For example press 9NEAR 16MON the number 16 sub screen of number 9 monitor will be selected and then press 9NEAR 8MON the number 8 sub screen of number 9 monitor will be reselected 4 6 Operation Mode of Matrix 4 6 1 Camera Control The real time video from the camera and the relevant system information will be displayed on the monitor after the desire...

Страница 21: ...n permits the simultaneous display of multiple camera scenes on a group of contiguous monitors providing surveillance over multiple sites at the same time To call a Salvo 1 Call the first monitor for the desired system salvo 2 Enter the system salvo number on the numeric keypad 3 Press the SALVO key to run the salvo Note Salvos can be automatically called from system tours alarm contacts and other...

Страница 22: ...sing the keypad enter a number between 1 and 60 to set the dwell time for the on screen camera To stop and hold the tour on that camera enter 61 6 Once the desired dwell time has been entered press the PROG key to save it The on screen display will then show the time or HOLD if 61 was entered in Step 5 If no more cameras are to be included in the tour skip to step 9 otherwise continue with Step 7 ...

Страница 23: ...the PROG position 2 Enter the pattern setting number and then press PATRN key 3 Use the joystick to change the pan tilt and lens positions for the desired pattern 4 Enter and save the pattern number and then press the PATRN key to end the pattern setting process Note different protocols may have different preset number and pattern number please refer to each protocol 4 7 8 Camera Lockout In many s...

Страница 24: ...op HMACRO Macro No N A N A Table 4 1 Macro Command Format for Macro programming Command Parameter 1 Parameter 2 Parameter 3 Enter line feed tab and space are allowed in front of each command Only space and tab are allowed between parameter and comma The parameters are identified with a comma in between For example SWITCH 12 22 34 SWITCH 22 44 Each command is ended with line feed There s no capital...

Страница 25: ...ch is the default saving position Refer to formats below to edit Macro in text MACRO Macro number NAME Macro name CMD Macro command END User must program in sequence as above There s no capitalization requirement for the aforementioned MACRO NAME CMD and END Only space enter line feed and tab are allowed in front of MACRO Only space and tab are allowed between MACRO and Space enter line feed and t...

Страница 26: ...ace on V3010 real panel RJ45 connector For detailed connections please refer to the figure below Figure 5 1 Typical Connection Diagram 5 3 DVR Operation 1 RS 422 485 Control Mode UNIT indicate DVR number PTZ indicate PTZ status Options are OFF and ON The PTZ function can be enabled by PTZ key and disabled by ESC key To change DVR number press the UNIT key on keyboard or click UNIT on the virtual k...

Страница 27: ...rd makes video image fast backward while turning rightward makes video image fast forward during playback Rotate the inner ring to adjust frame rate put forward to make the frame rate bigger put back to make the frame rate smaller Appendix I Specifications General Commnunication Protocol RS232 RS422 485 Ethernet Matrix Dome Output Manchester RS 422 485 RS232 Selectable Baud Rate 1200 2400 4800 960...

Страница 28: ...ameter shall be 0 8000mm A lower diameter value tends to cause voltage loss and even system instability 0 8000 1 000 1 250 2 000 10 283 86 451 137 716 218 1811 551 20 141 42 225 68 358 109 905 275 30 94 28 150 45 238 72 603 183 40 70 21 112 34 179 54 452 137 50 56 17 90 27 143 43 362 110 60 47 14 75 22 119 36 301 91 70 40 12 64 19 102 31 258 78 80 35 10 56 17 89 27 226 68 90 31 9 50 15 79 24 201 6...

Страница 29: ... Use shielded cables or thread the cables through metal tubes for burial thus to ensure the electric connection to the metal tube In case it s difficult to thread the cable through the tube all the way it s acceptable to use tube threaded cables only at both ends of the transmission line yet the length in burial should be no less than 15 meters The cable sheath and the tube should be connected to ...

Страница 30: ...Infinova 51 Stouts Lane Monmouth Junction NJ 08852 U S A Tel 1 888 685 2002 USA only 1 732 355 9100 Fax 1 732 355 9101 sales infinova com V1 4 1310 ...