background image

-9- 

Chapter Three: Arming and Disarming 

Arming can be defined as activating the system. When the system is armed, it monitors 
the zones that are protected by the sensors. If a sensor detects an intrusion, the system 
generates an alarm.  

Certain sensors, such as smoke sensors, are always active regardless of system status. 

3.1: Arming the System 

Three arming modes are available: Full, Part and Perimeter. These modes enable you to 
arm your system accordingly  to suit different circumstances.  

 

Full Arming 

Full arming activates the entire system. This arming method is used 
when you intend to leave your home, leaving the premises empty. 

 

Part Arming 

This arming method enables you to arm a section of your home while 
remaining on a different part of the premises. 

 

Perimeter Arming 

Perimeter arming enables you to activate the perimeter zones (the 
windows and doors of your home) enabling you to move freely within 
the protected area. 

Before arming the system, check that all doors and windows are secured so that the 
system is ready for arming. 

To arm the system using the keypad: 

• 

Press one of the three arming keys; the exit delay begins to count down. At the 

end of the exit delay, the system is armed. 

,

If the One-key Arming option is disabled in programming, you must enter your user code 
when arming the system.  

To arm the system using a keyfob: 

• 

Press the relevant button on your keyfob (see 2.2: Keyfobs); the exit delay 

begins to count down. At the end of the exit delay, the system is armed. 

Supervised Arm 

Supervised Arm is an optional feature designed to supervise intrusion sensor activity 
before you arm the system.  
If Supervised arm is enabled in programming and the system has not received a 
transmission from a sensor for a certain amount of time, all arming methods that include 
that sensor shall not be available. 
In this case, press   to check which sensor is causing the “System Not Ready” condition.  
To make the required arming method available, activate the sensor. If activating the sensor 
does not help, there may be a problem with the sensor. You can bypass the faulty sensor’s 
zone to allow system arming until the problem is remedied – 

see 7.2: Zone 

Bypassing/Unbypassing.

 

Содержание ZI250C

Страница 1: ......

Страница 2: ...log Number ZI250C 9 04 All data is subject to change without prior notice Hereby Electronics Line 3000 Ltd declares that this control panel is in compliance with the essential requirements and other r...

Страница 3: ...Disarming via SMS 11 Chapter Four Panic Alarms 12 4 1 Front Panel Keypad Alarms 12 4 2 Keyfob Panic Alarm 12 4 3 Wireless Keypad Panic Alarm 12 Chapter Five Home Automation 13 5 1 Keypad Control 13 5...

Страница 4: ...nt of a burglary a sensor sends a signal to the control panel indicating that it has sensed motion on the premises On receiving this signal the control panel makes the decision to report the alarm to...

Страница 5: ...wireless keypads or keyfobs Additionally each appliance can be programmed to be turned on and off automatically according to various schedules and system status conditions 1 4 Cellular Monitoring and...

Страница 6: ...tus of the system such as arm disarm alarm and power failure conditions System Trouble Indication In the event that the system detects a trouble condition System Trouble appears on the display To iden...

Страница 7: ...n each keyfob are shown below EL 2614 EL2611 2 3 Wireless Keypad The system supports up to four wireless keypads You can use the keypad as an arming station perform basic home automation functions and...

Страница 8: ...tion keys followed by the unit number 01 16 enables you to control lights and appliances in your home Cancel The Cancel key clears the keypad in the event that you pressed a key by mistake For example...

Страница 9: ...re secured so that the system is ready for arming To arm the system using the keypad Press one of the three arming keys the exit delay begins to count down At the end of the exit delay the system is a...

Страница 10: ...s the disarm button see 2 2 Keyfobs 3 3 Arm Status Indication The system s arm status is displayed on the front panel only The following table explains the various arm status descriptions that appear...

Страница 11: ...s of free text separates the descriptor from the actual command User Code Command 120 Disarm 121 Full Arm 122 Part Arm 123 Perimeter Arm 124 Full Perimeter Arm 125 Part Perimeter Arm The following exa...

Страница 12: ...old down keys 1 and 3 simultaneously To activate a Medical alarm from the front panel keypad Press and hold down keys 4 and 6 simultaneously 4 2 Keyfob Panic Alarm To activate a Panic alarm using the...

Страница 13: ...o send On and Off commands to HA units How an HA unit reacts to the On command is determined by the installer in programming The HA unit can be programmed to switch on until the Off command is receive...

Страница 14: ...allows you to set an On and Off time for each HA unit At these times the system automatically switches the HA unit on and off You can also choose the days of the week that the schedule is active On T...

Страница 15: ...method 1 Dial your telephone number 2 Wait for two or three rings then hang up 3 Wait at least five seconds and dial the number again on the second ring the control panel picks up and sounds two tone...

Страница 16: ...e control panel to call you in the event of an alarm so that you may check your family and home When the control panel calls you will hear two short tones when you pick up the phone Press any key on y...

Страница 17: ...ayed item Pressing also takes you back to the previous menu level Menu mode automatically terminates two minutes after the last keystroke Throughout this chapter we have tried to include all of the sy...

Страница 18: ...can edit all other user codes Additionally the Master code grants access to the Event Log the Service menu and Home Automation Schedule programming The default Master code is 1234 Change this code imm...

Страница 19: ...ct the code you want to delete 3 From the code s sub menu select Edit Code the 4 digit code is displayed with the cursor flashing on the first digit 4 Enter 0000 5 Press the code is deleted The Master...

Страница 20: ...log is full the oldest events are automatically erased and are replaced by new events To view the event log 1 From the Event Log menu select View Log 61 the most recent event is displayed 2 Use the ar...

Страница 21: ...t 703 the internal siren is sounded briefly Speaker Test To test the speaker From the Service menu select Speaker Test 704 a short sequence of chimes are sounded from the speaker Walk Test Walk Test m...

Страница 22: ...en you have finished press to exit TX Test mode Audio Volume To adjust the sensitivity of the microphone and the volume of the speaker 1 Establish a two way audio connection 2 From the Service menu se...

Страница 23: ...the system can be programmed to sound a chime each time the front door is opened or closed The Global Chime option enables you to turn this feature on and off To enable or disable Global Chime 1 From...

Страница 24: ...24 Appendix A Menu Structure Legend Installer code required Master code required...

Страница 25: ...g service when used to arm or disarm D Delay The exit entry delay times that allow the user to arm or disarm the system without generating an alarm Descriptor Custom labels programmed for each user co...

Страница 26: ...led Code A user code that does not cause the system to notify the monitoring service when used to arm or disarm The system only reports if the code is used to disarm after an alarm O One Key Arming Ar...

Страница 27: ...ng service System Status Indicators Luminous indicators on the front panel that provide information on the arm and power status of the system T Tones Chimes sounded by the control panel s internal or...

Отзывы: