Infinite L-com SRCN-C711-1 Скачать руководство пользователя страница 3

Board Mount 

Mount the PCB to the enclosure with screws. Mounting hole diameter is 3mm. 

Mounting Diagram 

35mm DIN rail mounting: Mount the sensor module onto the DIN rail (dark black) as shown in the figure.   

Notes 

1. 

The module has the function of anti-reverse connection. But it is still necessary to pay attention to the voltage polarity when the power is turned 

ON to avoid damage to the module. 

2. 

The modules are tested with pure resistance loads when they leave the factory. If user uses inductive or capacitive loads, there can be deviation 

in the reading. Kindly contact the customer support team for assistant.  

3. 

When the module is connected to the computer for debugging, please use the USB to 485 modules for debugging. 

Отзывы: